... ... @@ -316,6 +316,8 @@
316 316  )))
317 317  )))
318 318  
319 +
320 +
319 319  === 3.3.2 Configure sensors ===
320 320  
321 321  (((
... ... @@ -463,6 +463,7 @@
463 463  * **c: define the position for valid value.  **
464 464  )))
465 465  
468 +
466 466  **Examples:**
467 467  
468 468  * Grab bytes:
... ... @@ -525,7 +525,7 @@
525 525  )))
526 526  
527 527  (((
528 -(% style="color:#037691" %)**Examples: AT+DATAUP=0**
531 +(% style="color:#4f81bd" %)**Examples: AT+DATAUP=0**
529 529  )))
530 530  
531 531  (((
... ... @@ -537,7 +537,7 @@
537 537  )))
538 538  
539 539  (((
540 -(% style="color:#4f81bd" %)**Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx**
543 +(% style="color:#4f81bd" %)Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx
541 541  )))
542 542  
543 543  (((
... ... @@ -547,9 +547,8 @@
547 547  [[image:1653272787040-634.png||height="515" width="719"]]
548 548  
549 549  
550 -
551 551  (((
552 -(% style="color:#037691" %)**Examples: AT+DATAUP=1**
554 +(% style="color:#4f81bd" %)**Examples: AT+DATAUP=1**
553 553  
554 554  
555 555  )))
... ... @@ -563,7 +563,7 @@
563 563  )))
564 564  
565 565  (((
566 -(% style="color:#4f81bd" %)**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**
568 +(% style="color:#4f81bd" %)Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA
567 567  )))
568 568  
569 569  1. (((
... ... @@ -586,7 +586,6 @@
586 586  
587 587  So totally there will be 3 uplinks for this sampling, each uplink includes 6 bytes DATA
588 588  
589 -
590 590  DATA1=RETURN1 Valid Value = (% style="background-color:#4f81bd; color:white" %) 20 20 0a 33 90 41
591 591  
592 592  DATA2=1^^st^^ ~~ 6^^th^^ byte of Valid value of RETURN10= (% style="background-color:#4f81bd; color:white" %)02 aa 05 81 0a 20
... ... @@ -593,12 +593,10 @@
593 593  
594 594  DATA3=7^^th^^ ~~ 11^^th^^ bytes of Valid value of RETURN10 =(% style="background-color:#4f81bd; color:white" %) 20 20 20 2d 30
595 595  
596 -
597 597  Below are the uplink payloads:
598 598  
599 599  [[image:1653272901032-107.png]]
600 600  
601 -
602 602  (% style="color:red" %)Notice: the Max bytes is according to the max support bytes in different Frequency Bands for lowest SF. As below:
603 603  
604 604   ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink ( so 51 -5 = 46 max valid date)
... ... @@ -609,8 +609,6 @@
609 609  
610 610   ~* For all other bands: max 51 bytes for each uplink  ( so 51 -5 = 46 max valid date).
611 611  
612 -
613 -
614 614  === 3.3.5 Uplink on demand ===
615 615  
616 616  (((
... ... @@ -627,8 +627,6 @@
627 627  
628 628  (((
629 629  **0xA8 command**: Send a command to RS485-BL and uplink the output from sensors.
630 -
631 -
632 632  )))
633 633  
634 634  === 3.3.6 Uplink on Interrupt ===
... ... @@ -637,7 +637,6 @@
637 637  
638 638  [[image:1653273818896-432.png]]
639 639  
640 -
641 641  (((
642 642  AT+INTMOD=0  Disable Interrupt
643 643  )))
... ... @@ -652,8 +652,6 @@
652 652  
653 653  (((
654 654  AT+INTMOD=3  Interrupt trigger by rising edge.
655 -
656 -
657 657  )))
658 658  
659 659  == 3.4 Uplink Payload ==
... ... @@ -681,49 +681,47 @@
681 681  Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
682 682  
683 683  (((
684 -{{{function Decoder(bytes, port) {}}}
676 +function Decoder(bytes, port) {
685 685  )))
686 686  
687 687  (((
688 -{{{//Payload Formats of RS485-BL Deceive}}}
680 +~/~/Payload Formats of RS485-BL Deceive
689 689  )))
690 690  
691 691  (((
692 -{{{return {}}}
684 +return {
693 693  )))
694 694  
695 695  (((
696 -{{{ //Battery,units:V}}}
688 + ~/~/Battery,units:V
697 697  )))
698 698  
699 699  (((
700 -{{{ BatV:((bytes[0]<<8 | bytes[1])&0x7fff)/1000,}}}
692 + BatV:((bytes[0]<<8 | bytes[1])&0x7fff)/1000,
701 701  )))
702 702  
703 703  (((
704 -{{{ //GPIO_EXTI }}}
696 + ~/~/GPIO_EXTI 
705 705  )))
706 706  
707 707  (((
708 -{{{ EXTI_Trigger:(bytes[0] & 0x80)? "TRUE":"FALSE",}}}
700 + EXTI_Trigger:(bytes[0] & 0x80)? "TRUE":"FALSE",
709 709  )))
710 710  
711 711  (((
712 -{{{ //payload of version}}}
704 + ~/~/payload of version
713 713  )))
714 714  
715 715  (((
716 -{{{ Pay_ver:bytes[2],}}}
708 + Pay_ver:bytes[2],
717 717  )))
718 718  
719 719  (((
720 -{{{ }; }}}
712 + };
721 721  )))
722 722  
723 723  (((
724 -}
725 -
726 -
716 + }
727 727  )))
728 728  
729 729  (((
... ... @@ -732,30 +732,29 @@
732 732  
733 733  [[image:1653274001211-372.png||height="192" width="732"]]
734 734  
735 -
736 736  == 3.5 Configure RS485-BL via AT or Downlink ==
737 737  
738 -User can configure RS485-BL via AT Commands or LoRaWAN Downlink Commands
727 +User can configure RS485-BL via [[AT Commands >>path:#_​Using_the_AT]]or LoRaWAN Downlink Commands
739 739  
740 740  There are two kinds of Commands:
741 741  
742 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
731 +* **Common Commands**: They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands
743 743  
744 -* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
733 +* **Sensor Related Commands**: These commands are special designed for RS485-BL.  User can see these commands below:
745 745  
735 +1.
736 +11.
737 +111. Common Commands:
746 746  
747 -=== 3.5.1 Common Commands: ===
739 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands]]
748 748  
749 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
750 750  
742 +1.
743 +11.
744 +111. Sensor related commands:
751 751  
752 -=== 3.5.2 Sensor related commands: ===