Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -743,8 +743,6 @@ 743 743 744 744 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL. User can see these commands below: 745 745 746 - 747 - 748 748 === 3.5.1 Common Commands: === 749 749 750 750 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -752,37 +752,47 @@ 752 752 753 753 === 3.5.2 Sensor related commands: === 754 754 755 -==== ChooseDeviceType (RS485 or TTL)====753 +==== ==== 756 756 755 +==== **Choose Device Type (RS485 or TTL)** ==== 756 + 757 757 RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect. 758 758 759 -* AT Command 759 +* **AT Command** 760 760 761 +(% class="box infomessage" %) 762 +((( 761 761 **AT+MOD=1** ~/~/ Set to support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins. 764 +))) 762 762 766 +(% class="box infomessage" %) 767 +((( 763 763 **AT+MOD=2** ~/~/ Set to support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins. 769 +))) 764 764 765 765 766 -* Downlink Payload 772 +* **Downlink Payload** 767 767 768 -**0A aa** àsame as AT+MOD=aa774 +**0A aa** ~-~-> same as AT+MOD=aa 769 769 770 770 771 771 772 -==== [[RS485 Debug Command>>path:#downlink_A8]](AT+CFGDEV) ====778 +==== **RS485 Debug Command (AT+CFGDEV)** ==== 773 773 774 774 This command is used to configure the RS485 or TTL sensors; they won’t be used during sampling. 775 775 776 -* AT Command 782 +* **AT Command** 777 777 778 -AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 784 +(% class="box infomessage" %) 785 +((( 786 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 787 +))) 779 779 780 780 m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command. 781 781 782 782 792 +* **Downlink Payload** 783 783 784 -* Downlink Payload 785 - 786 786 Format: A8 MM NN XX XX XX XX YY 787 787 788 788 Where: ... ... @@ -796,15 +796,15 @@ 796 796 797 797 To connect a Modbus Alarm with below commands. 798 798 799 -* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 807 +* The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 800 800 801 -* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 809 +* The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 802 802 803 803 So if user want to use downlink command to control to RS485 Alarm, he can use: 804 804 805 -**A8 01 06 0A 05 00 04 00 01 00**: to activate the RS485 Alarm 813 +(% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm 806 806 807 -**A8 01 06 0A 05 00 04 00 00 00**: to deactivate the RS485 Alarm 815 +(% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm 808 808 809 809 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output. 810 810 ... ... @@ -813,48 +813,60 @@ 813 813 814 814 Check TTL Sensor return: 815 815 816 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]824 +[[image:1654132684752-193.png]] 817 817 818 818 819 819 828 +==== **Set Payload version** ==== 820 820 821 -==== Set Payload version ==== 822 - 823 823 This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. 824 824 825 -* AT Command: 832 +* **AT Command:** 826 826 827 -AT+PAYVER: Set PAYVER field = 1 834 +(% class="box infomessage" %) 835 +((( 836 +**AT+PAYVER: Set PAYVER field = 1** 837 +))) 828 828 829 829 830 -* Downlink Payload: 840 +* **Downlink Payload:** 831 831 832 -0xAE 01 àSet PAYVER field = 0x01842 +**0xAE 01** ~-~-> Set PAYVER field = 0x01 833 833 834 -0xAE 0F àSet PAYVER field = 0x0F844 +**0xAE 0F** ~-~-> Set PAYVER field = 0x0F 835 835 836 836 837 -==== Set RS485 Sampling Commands ==== 838 838 848 +==== **Set RS485 Sampling Commands** ==== 849 + 839 839 AT+COMMANDx, AT+DATACUTx and AT+SEARCHx 840 840 841 -These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>> path:#polling_485]].852 +These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 842 842 843 843 844 -* AT Command: 855 +* **AT Command:** 845 845 846 -AT+COMMANDx: Configure RS485 read command to sensor. 857 +(% class="box infomessage" %) 858 +((( 859 +**AT+COMMANDx: Configure RS485 read command to sensor.** 860 +))) 847 847 848 -AT+DATACUTx: Configure how to handle return from RS485 devices. 862 +(% class="box infomessage" %) 863 +((( 864 +**AT+DATACUTx: Configure how to handle return from RS485 devices.** 865 +))) 849 849 850 -AT+SEARCHx: Configure search command 867 +(% class="box infomessage" %) 868 +((( 869 +**AT+SEARCHx: Configure search command** 870 +))) 851 851 852 852 853 -* Downlink Payload: 873 +* **Downlink Payload:** 854 854 855 -0xAF downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 875 +**0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 856 856 857 -Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 877 +(% style="color:red" %)**Note**(%%): if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 858 858 859 859 Format: AF MM NN LL XX XX XX XX YY 860 860 ... ... @@ -861,18 +861,18 @@ 861 861 Where: 862 862 863 863 * MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 864 -* NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 865 -* LL: The length of AT+COMMAND or AT+DATACUT command 884 +* NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 885 +* LL: The length of AT+COMMAND or AT+DATACUT command 866 866 * XX XX XX XX: AT+COMMAND or AT+DATACUT command 867 -* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command. 887 +* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command. 868 868 869 -Example: 889 +**Example:** 870 870 871 -**AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1 891 +(% style="color:#037691" %)**AF 03 01 06 0A 05 00 04 00 01 00**(%%): Same as AT+COMMAND3=0A 05 00 04 00 01,1 872 872 873 -**AF 03 02 06 10 01 05 06 09 0A 00**: Same as AT+DATACUT3=**16**,**1**,**5+6+9+10** 893 +(% style="color:#037691" %)**AF 03 02 06**(% style="color:orange" %)** 10 **(% style="color:red" %)**01 **(% style="color:green" %)**05 06 09 0A**(% style="color:#037691" %)** 00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**16**(%%),(% style="color:red" %)**1**(%%),(% style="color:green" %)**5+6+9+10** 874 874 875 -**AF 03 02 06 0B 02 05 07 08 0A 00**: Same as AT+DATACUT3=**11**,**2**,**5~~7+8~~10** 895 +(% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10** 876 876 877 877 878 878 0xAB downlink command can be used for set AT+SEARCHx ... ... @@ -1055,13 +1055,13 @@ 1055 1055 1056 1056 1057 1057 1058 -1. 1078 +1. 1059 1059 11. Buttons 1060 1060 1061 1061 |**Button**|**Feature** 1062 1062 |**RST**|Reboot RS485-BL 1063 1063 1064 -1. 1084 +1. 1065 1065 11. +3V3 Output 1066 1066 1067 1067 RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor. ... ... @@ -1079,7 +1079,7 @@ 1079 1079 By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time 1080 1080 1081 1081 1082 -1. 1102 +1. 1083 1083 11. +5V Output 1084 1084 1085 1085 RS485-BL has a Controllable +5V output, user can use this output to power external sensor. ... ... @@ -1099,13 +1099,13 @@ 1099 1099 1100 1100 1101 1101 1102 -1. 1122 +1. 1103 1103 11. LEDs 1104 1104 1105 1105 |**LEDs**|**Feature** 1106 1106 |**LED1**|Blink when device transmit a packet. 1107 1107 1108 -1. 1128 +1. 1109 1109 11. Switch Jumper 1110 1110 1111 1111 |**Switch Jumper**|**Feature** ... ... @@ -1151,7 +1151,7 @@ 1151 1151 1152 1152 1153 1153 1154 -1. 1174 +1. 1155 1155 11. Common AT Command Sequence 1156 1156 111. Multi-channel ABP mode (Use with SX1301/LG308) 1157 1157 ... ... @@ -1170,8 +1170,8 @@ 1170 1170 1171 1171 ATZ 1172 1172 1173 -1. 1174 -11. 1193 +1. 1194 +11. 1175 1175 111. Single-channel ABP mode (Use with LG01/LG02) 1176 1176 1177 1177 AT+FDR Reset Parameters to Factory Default, Keys Reserve ... ... @@ -1246,7 +1246,7 @@ 1246 1246 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] 1247 1247 1248 1248 1249 -1. 1269 +1. 1250 1250 11. How to change the LoRa Frequency Bands/Region? 1251 1251 1252 1252 User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download. ... ... @@ -1253,7 +1253,7 @@ 1253 1253 1254 1254 1255 1255 1256 -1. 1276 +1. 1257 1257 11. How many RS485-Slave can RS485-BL connects? 1258 1258 1259 1259 The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]]. ... ... @@ -1270,7 +1270,7 @@ 1270 1270 1271 1271 1272 1272 1273 -1. 1293 +1. 1274 1274 11. Why I can’t join TTN V3 in US915 /AU915 bands? 1275 1275 1276 1276 It might about the channels mapping. Please see for detail.
- 1654132684752-193.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.8 KB - Content