Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -752,11 +752,13 @@ 752 752 753 753 === 3.5.2 Sensor related commands: === 754 754 755 -==== ChooseDeviceType (RS485 or TTL)====755 +==== ==== 756 756 757 +==== **Choose Device Type (RS485 or TTL)** ==== 758 + 757 757 RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect. 758 758 759 -* AT Command 761 +* **AT Command** 760 760 761 761 **AT+MOD=1** ~/~/ Set to support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins. 762 762 ... ... @@ -763,17 +763,17 @@ 763 763 **AT+MOD=2** ~/~/ Set to support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins. 764 764 765 765 766 -* Downlink Payload 768 +* **Downlink Payload** 767 767 768 -**0A aa** àsame as AT+MOD=aa770 +**0A aa** ~-~-> same as AT+MOD=aa 769 769 770 770 771 771 772 -==== [[RS485 Debug Command>>path:#downlink_A8]](AT+CFGDEV) ====774 +==== **RS485 Debug Command (AT+CFGDEV)** ==== 773 773 774 774 This command is used to configure the RS485 or TTL sensors; they won’t be used during sampling. 775 775 776 -* AT Command 778 +* **AT Command** 777 777 778 778 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 779 779 ... ... @@ -780,9 +780,8 @@ 780 780 m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command. 781 781 782 782 785 +* **Downlink Payload** 783 783 784 -* Downlink Payload 785 - 786 786 Format: A8 MM NN XX XX XX XX YY 787 787 788 788 Where: ... ... @@ -796,15 +796,15 @@ 796 796 797 797 To connect a Modbus Alarm with below commands. 798 798 799 -* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 800 +* The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 800 800 801 -* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 802 +* The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 802 802 803 803 So if user want to use downlink command to control to RS485 Alarm, he can use: 804 804 805 -**A8 01 06 0A 05 00 04 00 01 00**: to activate the RS485 Alarm 806 +(% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm 806 806 807 -**A8 01 06 0A 05 00 04 00 00 00**: to deactivate the RS485 Alarm 808 +(% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm 808 808 809 809 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output. 810 810 ... ... @@ -813,7 +813,7 @@ 813 813 814 814 Check TTL Sensor return: 815 815 816 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]817 +[[image:1654132684752-193.png]] 817 817 818 818 819 819 ... ... @@ -1055,13 +1055,13 @@ 1055 1055 1056 1056 1057 1057 1058 -1. 1059 +1. 1059 1059 11. Buttons 1060 1060 1061 1061 |**Button**|**Feature** 1062 1062 |**RST**|Reboot RS485-BL 1063 1063 1064 -1. 1065 +1. 1065 1065 11. +3V3 Output 1066 1066 1067 1067 RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor. ... ... @@ -1079,7 +1079,7 @@ 1079 1079 By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time 1080 1080 1081 1081 1082 -1. 1083 +1. 1083 1083 11. +5V Output 1084 1084 1085 1085 RS485-BL has a Controllable +5V output, user can use this output to power external sensor. ... ... @@ -1099,13 +1099,13 @@ 1099 1099 1100 1100 1101 1101 1102 -1. 1103 +1. 1103 1103 11. LEDs 1104 1104 1105 1105 |**LEDs**|**Feature** 1106 1106 |**LED1**|Blink when device transmit a packet. 1107 1107 1108 -1. 1109 +1. 1109 1109 11. Switch Jumper 1110 1110 1111 1111 |**Switch Jumper**|**Feature** ... ... @@ -1151,7 +1151,7 @@ 1151 1151 1152 1152 1153 1153 1154 -1. 1155 +1. 1155 1155 11. Common AT Command Sequence 1156 1156 111. Multi-channel ABP mode (Use with SX1301/LG308) 1157 1157 ... ... @@ -1170,8 +1170,8 @@ 1170 1170 1171 1171 ATZ 1172 1172 1173 -1. 1174 -11. 1174 +1. 1175 +11. 1175 1175 111. Single-channel ABP mode (Use with LG01/LG02) 1176 1176 1177 1177 AT+FDR Reset Parameters to Factory Default, Keys Reserve ... ... @@ -1246,7 +1246,7 @@ 1246 1246 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] 1247 1247 1248 1248 1249 -1. 1250 +1. 1250 1250 11. How to change the LoRa Frequency Bands/Region? 1251 1251 1252 1252 User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download. ... ... @@ -1253,7 +1253,7 @@ 1253 1253 1254 1254 1255 1255 1256 -1. 1257 +1. 1257 1257 11. How many RS485-Slave can RS485-BL connects? 1258 1258 1259 1259 The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]]. ... ... @@ -1270,7 +1270,7 @@ 1270 1270 1271 1271 1272 1272 1273 -1. 1274 +1. 1274 1274 11. Why I can’t join TTN V3 in US915 /AU915 bands? 1275 1275 1276 1276 It might about the channels mapping. Please see for detail.
- 1654132684752-193.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.8 KB - Content