Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -316,7 +316,6 @@ 316 316 ))) 317 317 ))) 318 318 319 - 320 320 === 3.3.2 Configure sensors === 321 321 322 322 ((( ... ... @@ -722,7 +722,7 @@ 722 722 ))) 723 723 724 724 ((( 725 - {{{}}}}724 +} 726 726 727 727 728 728 ))) ... ... @@ -736,56 +736,62 @@ 736 736 737 737 == 3.5 Configure RS485-BL via AT or Downlink == 738 738 739 -User can configure RS485-BL via [[AT Commands>>path:#_Using_the_AT]]or LoRaWAN Downlink Commands738 +User can configure RS485-BL via AT Commands or LoRaWAN Downlink Commands 740 740 741 741 There are two kinds of Commands: 742 742 743 -* **Common Commands**: They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands742 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 744 744 745 -* **Sensor Related Commands**: These commands are special designed for RS485-BL. User can see these commands below: 744 +* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL. User can see these commands below: 746 746 747 -1. 748 -11. 749 -111. Common Commands: 746 +=== 3.5.1 Common Commands: === 750 750 751 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[ http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands]]748 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 752 752 753 753 754 -1. 755 -11. 756 -111. Sensor related commands: 751 +=== 3.5.2 Sensor related commands: === 757 757 758 -==== ChooseDeviceType (RS485 or TTL)====753 +==== ==== 759 759 755 +==== **Choose Device Type (RS485 or TTL)** ==== 756 + 760 760 RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect. 761 761 762 -* AT Command 759 +* **AT Command** 763 763 761 +(% class="box infomessage" %) 762 +((( 764 764 **AT+MOD=1** ~/~/ Set to support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins. 764 +))) 765 765 766 +(% class="box infomessage" %) 767 +((( 766 766 **AT+MOD=2** ~/~/ Set to support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins. 769 +))) 767 767 768 768 769 -* Downlink Payload 772 +* **Downlink Payload** 770 770 771 -**0A aa** àsame as AT+MOD=aa774 +**0A aa** ~-~-> same as AT+MOD=aa 772 772 773 773 774 774 775 -==== [[RS485 Debug Command>>path:#downlink_A8]](AT+CFGDEV) ====778 +==== **RS485 Debug Command (AT+CFGDEV)** ==== 776 776 777 777 This command is used to configure the RS485 or TTL sensors; they won’t be used during sampling. 778 778 779 -* AT Command 782 +* **AT Command** 780 780 781 -AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 784 +(% class="box infomessage" %) 785 +((( 786 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 787 +))) 782 782 783 783 m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command. 784 784 785 785 792 +* **Downlink Payload** 786 786 787 -* Downlink Payload 788 - 789 789 Format: A8 MM NN XX XX XX XX YY 790 790 791 791 Where: ... ... @@ -799,15 +799,15 @@ 799 799 800 800 To connect a Modbus Alarm with below commands. 801 801 802 -* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 807 +* The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 803 803 804 -* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 809 +* The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 805 805 806 806 So if user want to use downlink command to control to RS485 Alarm, he can use: 807 807 808 -**A8 01 06 0A 05 00 04 00 01 00**: to activate the RS485 Alarm 813 +(% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm 809 809 810 -**A8 01 06 0A 05 00 04 00 00 00**: to deactivate the RS485 Alarm 815 +(% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm 811 811 812 812 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output. 813 813 ... ... @@ -816,48 +816,60 @@ 816 816 817 817 Check TTL Sensor return: 818 818 819 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]824 +[[image:1654132684752-193.png]] 820 820 821 821 822 822 828 +==== **Set Payload version** ==== 823 823 824 -==== Set Payload version ==== 825 - 826 826 This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. 827 827 828 -* AT Command: 832 +* **AT Command:** 829 829 830 -AT+PAYVER: Set PAYVER field = 1 834 +(% class="box infomessage" %) 835 +((( 836 +**AT+PAYVER: Set PAYVER field = 1** 837 +))) 831 831 832 832 833 -* Downlink Payload: 840 +* **Downlink Payload:** 834 834 835 -0xAE 01 àSet PAYVER field = 0x01842 +**0xAE 01** ~-~-> Set PAYVER field = 0x01 836 836 837 -0xAE 0F àSet PAYVER field = 0x0F844 +**0xAE 0F** ~-~-> Set PAYVER field = 0x0F 838 838 839 839 840 -==== Set RS485 Sampling Commands ==== 841 841 848 +==== **Set RS485 Sampling Commands** ==== 849 + 842 842 AT+COMMANDx, AT+DATACUTx and AT+SEARCHx 843 843 844 -These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>> path:#polling_485]].852 +These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 845 845 846 846 847 -* AT Command: 855 +* **AT Command:** 848 848 849 -AT+COMMANDx: Configure RS485 read command to sensor. 857 +(% class="box infomessage" %) 858 +((( 859 +**AT+COMMANDx: Configure RS485 read command to sensor.** 860 +))) 850 850 851 -AT+DATACUTx: Configure how to handle return from RS485 devices. 862 +(% class="box infomessage" %) 863 +((( 864 +**AT+DATACUTx: Configure how to handle return from RS485 devices.** 865 +))) 852 852 853 -AT+SEARCHx: Configure search command 867 +(% class="box infomessage" %) 868 +((( 869 +**AT+SEARCHx: Configure search command** 870 +))) 854 854 855 855 856 -* Downlink Payload: 873 +* **Downlink Payload:** 857 857 858 -0xAF downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 875 +**0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 859 859 860 -Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 877 +(% style="color:red" %)**Note**(%%): if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 861 861 862 862 Format: AF MM NN LL XX XX XX XX YY 863 863 ... ... @@ -864,18 +864,18 @@ 864 864 Where: 865 865 866 866 * MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 867 -* NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 868 -* LL: The length of AT+COMMAND or AT+DATACUT command 884 +* NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 885 +* LL: The length of AT+COMMAND or AT+DATACUT command 869 869 * XX XX XX XX: AT+COMMAND or AT+DATACUT command 870 -* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command. 887 +* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command. 871 871 872 -Example: 889 +**Example:** 873 873 874 -**AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1 891 +(% style="color:#037691" %)**AF 03 01 06 0A 05 00 04 00 01 00**(%%): Same as AT+COMMAND3=0A 05 00 04 00 01,1 875 875 876 -**AF 03 02 06 10 01 05 06 09 0A 00**: Same as AT+DATACUT3=**16**,**1**,**5+6+9+10** 893 +(% style="color:#037691" %)**AF 03 02 06**(% style="color:orange" %)** 10 **(% style="color:red" %)**01 **(% style="color:green" %)**05 06 09 0A**(% style="color:#037691" %)** 00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**16**(%%),(% style="color:red" %)**1**(%%),(% style="color:green" %)**5+6+9+10** 877 877 878 -**AF 03 02 06 0B 02 05 07 08 0A 00**: Same as AT+DATACUT3=**11**,**2**,**5~~7+8~~10** 895 +(% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10** 879 879 880 880 881 881 0xAB downlink command can be used for set AT+SEARCHx
- 1654132684752-193.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.8 KB - Content