Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -316,7 +316,6 @@ 316 316 ))) 317 317 ))) 318 318 319 - 320 320 === 3.3.2 Configure sensors === 321 321 322 322 ((( ... ... @@ -638,6 +638,7 @@ 638 638 639 639 [[image:1653273818896-432.png]] 640 640 640 + 641 641 ((( 642 642 AT+INTMOD=0 Disable Interrupt 643 643 ))) ... ... @@ -652,6 +652,8 @@ 652 652 653 653 ((( 654 654 AT+INTMOD=3 Interrupt trigger by rising edge. 655 + 656 + 655 655 ))) 656 656 657 657 == 3.4 Uplink Payload == ... ... @@ -679,47 +679,49 @@ 679 679 Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors. 680 680 681 681 ((( 682 -function Decoder(bytes, port) { 684 +{{{function Decoder(bytes, port) {}}} 683 683 ))) 684 684 685 685 ((( 686 - ~/~/Payload Formats of RS485-BL Deceive688 +{{{//Payload Formats of RS485-BL Deceive}}} 687 687 ))) 688 688 689 689 ((( 690 -return { 692 +{{{return {}}} 691 691 ))) 692 692 693 693 ((( 694 - ~/~/Battery,units:V696 +{{{ //Battery,units:V}}} 695 695 ))) 696 696 697 697 ((( 698 - BatV:((bytes[0]<<8 | bytes[1])&0x7fff)/1000, 700 +{{{ BatV:((bytes[0]<<8 | bytes[1])&0x7fff)/1000,}}} 699 699 ))) 700 700 701 701 ((( 702 - ~/~/GPIO_EXTI704 +{{{ //GPIO_EXTI }}} 703 703 ))) 704 704 705 705 ((( 706 - EXTI_Trigger:(bytes[0] & 0x80)? "TRUE":"FALSE", 708 +{{{ EXTI_Trigger:(bytes[0] & 0x80)? "TRUE":"FALSE",}}} 707 707 ))) 708 708 709 709 ((( 710 - ~/~/payload of version712 +{{{ //payload of version}}} 711 711 ))) 712 712 713 713 ((( 714 - Pay_ver:bytes[2], 716 +{{{ Pay_ver:bytes[2],}}} 715 715 ))) 716 716 717 717 ((( 718 - }; 720 +{{{ }; }}} 719 719 ))) 720 720 721 721 ((( 722 - } 724 +} 725 + 726 + 723 723 ))) 724 724 725 725 ((( ... ... @@ -728,58 +728,66 @@ 728 728 729 729 [[image:1653274001211-372.png||height="192" width="732"]] 730 730 735 + 731 731 == 3.5 Configure RS485-BL via AT or Downlink == 732 732 733 -User can configure RS485-BL via [[AT Commands>>path:#_Using_the_AT]]or LoRaWAN Downlink Commands738 +User can configure RS485-BL via AT Commands or LoRaWAN Downlink Commands 734 734 735 735 There are two kinds of Commands: 736 736 737 -* **Common Commands**: They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands742 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 738 738 739 -* **Sensor Related Commands**: These commands are special designed for RS485-BL. User can see these commands below: 744 +* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL. User can see these commands below: 740 740 741 -1. 742 -11. 743 -111. Common Commands: 744 744 745 - Theyshould be available for each of Dragino Sensors, such as: change uplink interval, reset device.For firmware v1.3,user can find what commoncommandsit supports:[[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands]]747 +=== 3.5.1 Common Commands: === 746 746 749 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 747 747 748 -1. 749 -11. 750 -111. Sensor related commands: 751 751 752 -=== =ChooseDeviceType (RS485orTTL)====752 +=== 3.5.2 Sensor related commands: === 753 753 754 +==== ==== 755 + 756 +==== **Choose Device Type (RS485 or TTL)** ==== 757 + 754 754 RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect. 755 755 756 -* AT Command 760 +* **AT Command** 757 757 762 +(% class="box infomessage" %) 763 +((( 758 758 **AT+MOD=1** ~/~/ Set to support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins. 765 +))) 759 759 767 +(% class="box infomessage" %) 768 +((( 760 760 **AT+MOD=2** ~/~/ Set to support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins. 770 +))) 761 761 762 762 763 -* Downlink Payload 773 +* **Downlink Payload** 764 764 765 -**0A aa** àsame as AT+MOD=aa775 +**0A aa** ~-~-> same as AT+MOD=aa 766 766 767 767 768 768 769 -==== [[RS485 Debug Command>>path:#downlink_A8]](AT+CFGDEV) ====779 +==== **RS485 Debug Command (AT+CFGDEV)** ==== 770 770 771 771 This command is used to configure the RS485 or TTL sensors; they won’t be used during sampling. 772 772 773 -* AT Command 783 +* **AT Command** 774 774 775 -AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 785 +(% class="box infomessage" %) 786 +((( 787 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 788 +))) 776 776 777 777 m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command. 778 778 779 779 793 +* **Downlink Payload** 780 780 781 -* Downlink Payload 782 - 783 783 Format: A8 MM NN XX XX XX XX YY 784 784 785 785 Where: ... ... @@ -793,15 +793,15 @@ 793 793 794 794 To connect a Modbus Alarm with below commands. 795 795 796 -* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 808 +* The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 797 797 798 -* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 810 +* The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 799 799 800 800 So if user want to use downlink command to control to RS485 Alarm, he can use: 801 801 802 -**A8 01 06 0A 05 00 04 00 01 00**: to activate the RS485 Alarm 814 +(% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm 803 803 804 -**A8 01 06 0A 05 00 04 00 00 00**: to deactivate the RS485 Alarm 816 +(% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm 805 805 806 806 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output. 807 807 ... ... @@ -810,32 +810,35 @@ 810 810 811 811 Check TTL Sensor return: 812 812 813 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]825 +[[image:1654132684752-193.png]] 814 814 815 815 816 816 829 +==== **Set Payload version** ==== 817 817 818 -==== Set Payload version ==== 819 - 820 820 This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. 821 821 822 -* AT Command: 833 +* **AT Command:** 823 823 824 -AT+PAYVER: Set PAYVER field = 1 835 +(% class="box infomessage" %) 836 +((( 837 +**AT+PAYVER: Set PAYVER field = 1** 838 +))) 825 825 826 826 827 -* Downlink Payload: 841 +* **Downlink Payload:** 828 828 829 -0xAE 01 àSet PAYVER field = 0x01843 +**0xAE 01** ~-~-> Set PAYVER field = 0x01 830 830 831 -0xAE 0F àSet PAYVER field = 0x0F845 +**0xAE 0F** ~-~-> Set PAYVER field = 0x0F 832 832 833 833 834 -==== Set RS485 Sampling Commands ==== 835 835 849 +==== **Set RS485 Sampling Commands** ==== 850 + 836 836 AT+COMMANDx, AT+DATACUTx and AT+SEARCHx 837 837 838 -These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>> path:#polling_485]].853 +These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 839 839 840 840 841 841 * AT Command: ... ... @@ -1052,13 +1052,13 @@ 1052 1052 1053 1053 1054 1054 1055 -1. 1070 +1. 1056 1056 11. Buttons 1057 1057 1058 1058 |**Button**|**Feature** 1059 1059 |**RST**|Reboot RS485-BL 1060 1060 1061 -1. 1076 +1. 1062 1062 11. +3V3 Output 1063 1063 1064 1064 RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor. ... ... @@ -1076,7 +1076,7 @@ 1076 1076 By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time 1077 1077 1078 1078 1079 -1. 1094 +1. 1080 1080 11. +5V Output 1081 1081 1082 1082 RS485-BL has a Controllable +5V output, user can use this output to power external sensor. ... ... @@ -1096,13 +1096,13 @@ 1096 1096 1097 1097 1098 1098 1099 -1. 1114 +1. 1100 1100 11. LEDs 1101 1101 1102 1102 |**LEDs**|**Feature** 1103 1103 |**LED1**|Blink when device transmit a packet. 1104 1104 1105 -1. 1120 +1. 1106 1106 11. Switch Jumper 1107 1107 1108 1108 |**Switch Jumper**|**Feature** ... ... @@ -1148,7 +1148,7 @@ 1148 1148 1149 1149 1150 1150 1151 -1. 1166 +1. 1152 1152 11. Common AT Command Sequence 1153 1153 111. Multi-channel ABP mode (Use with SX1301/LG308) 1154 1154 ... ... @@ -1167,8 +1167,8 @@ 1167 1167 1168 1168 ATZ 1169 1169 1170 -1. 1171 -11. 1185 +1. 1186 +11. 1172 1172 111. Single-channel ABP mode (Use with LG01/LG02) 1173 1173 1174 1174 AT+FDR Reset Parameters to Factory Default, Keys Reserve ... ... @@ -1243,7 +1243,7 @@ 1243 1243 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] 1244 1244 1245 1245 1246 -1. 1261 +1. 1247 1247 11. How to change the LoRa Frequency Bands/Region? 1248 1248 1249 1249 User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download. ... ... @@ -1250,7 +1250,7 @@ 1250 1250 1251 1251 1252 1252 1253 -1. 1268 +1. 1254 1254 11. How many RS485-Slave can RS485-BL connects? 1255 1255 1256 1256 The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]]. ... ... @@ -1267,7 +1267,7 @@ 1267 1267 1268 1268 1269 1269 1270 -1. 1285 +1. 1271 1271 11. Why I can’t join TTN V3 in US915 /AU915 bands? 1272 1272 1273 1273 It might about the channels mapping. Please see for detail.
- 1654132684752-193.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.8 KB - Content