Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -316,7 +316,6 @@ 316 316 ))) 317 317 ))) 318 318 319 - 320 320 === 3.3.2 Configure sensors === 321 321 322 322 ((( ... ... @@ -628,6 +628,8 @@ 628 628 629 629 ((( 630 630 **0xA8 command**: Send a command to RS485-BL and uplink the output from sensors. 630 + 631 + 631 631 ))) 632 632 633 633 === 3.3.6 Uplink on Interrupt === ... ... @@ -636,6 +636,7 @@ 636 636 637 637 [[image:1653273818896-432.png]] 638 638 640 + 639 639 ((( 640 640 AT+INTMOD=0 Disable Interrupt 641 641 ))) ... ... @@ -650,6 +650,8 @@ 650 650 651 651 ((( 652 652 AT+INTMOD=3 Interrupt trigger by rising edge. 655 + 656 + 653 653 ))) 654 654 655 655 == 3.4 Uplink Payload == ... ... @@ -677,47 +677,49 @@ 677 677 Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors. 678 678 679 679 ((( 680 -function Decoder(bytes, port) { 684 +{{{function Decoder(bytes, port) {}}} 681 681 ))) 682 682 683 683 ((( 684 - ~/~/Payload Formats of RS485-BL Deceive688 +{{{//Payload Formats of RS485-BL Deceive}}} 685 685 ))) 686 686 687 687 ((( 688 -return { 692 +{{{return {}}} 689 689 ))) 690 690 691 691 ((( 692 - ~/~/Battery,units:V696 +{{{ //Battery,units:V}}} 693 693 ))) 694 694 695 695 ((( 696 - BatV:((bytes[0]<<8 | bytes[1])&0x7fff)/1000, 700 +{{{ BatV:((bytes[0]<<8 | bytes[1])&0x7fff)/1000,}}} 697 697 ))) 698 698 699 699 ((( 700 - ~/~/GPIO_EXTI704 +{{{ //GPIO_EXTI }}} 701 701 ))) 702 702 703 703 ((( 704 - EXTI_Trigger:(bytes[0] & 0x80)? "TRUE":"FALSE", 708 +{{{ EXTI_Trigger:(bytes[0] & 0x80)? "TRUE":"FALSE",}}} 705 705 ))) 706 706 707 707 ((( 708 - ~/~/payload of version712 +{{{ //payload of version}}} 709 709 ))) 710 710 711 711 ((( 712 - Pay_ver:bytes[2], 716 +{{{ Pay_ver:bytes[2],}}} 713 713 ))) 714 714 715 715 ((( 716 - }; 720 +{{{ }; }}} 717 717 ))) 718 718 719 719 ((( 720 - } 724 +} 725 + 726 + 721 721 ))) 722 722 723 723 ((( ... ... @@ -726,58 +726,66 @@ 726 726 727 727 [[image:1653274001211-372.png||height="192" width="732"]] 728 728 735 + 729 729 == 3.5 Configure RS485-BL via AT or Downlink == 730 730 731 -User can configure RS485-BL via [[AT Commands>>path:#_Using_the_AT]]or LoRaWAN Downlink Commands738 +User can configure RS485-BL via AT Commands or LoRaWAN Downlink Commands 732 732 733 733 There are two kinds of Commands: 734 734 735 -* **Common Commands**: They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands742 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 736 736 737 -* **Sensor Related Commands**: These commands are special designed for RS485-BL. User can see these commands below: 744 +* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL. User can see these commands below: 738 738 739 -1. 740 -11. 741 -111. Common Commands: 742 742 743 - Theyshould be available for each of Dragino Sensors, such as: change uplink interval, reset device.For firmware v1.3,user can find what commoncommandsit supports:[[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands]]747 +=== 3.5.1 Common Commands: === 744 744 749 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 745 745 746 -1. 747 -11. 748 -111. Sensor related commands: 749 749 750 -=== =ChooseDeviceType (RS485orTTL)====752 +=== 3.5.2 Sensor related commands: === 751 751 754 +==== ==== 755 + 756 +==== **Choose Device Type (RS485 or TTL)** ==== 757 + 752 752 RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect. 753 753 754 -* AT Command 760 +* **AT Command** 755 755 762 +(% class="box infomessage" %) 763 +((( 756 756 **AT+MOD=1** ~/~/ Set to support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins. 765 +))) 757 757 767 +(% class="box infomessage" %) 768 +((( 758 758 **AT+MOD=2** ~/~/ Set to support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins. 770 +))) 759 759 760 760 761 -* Downlink Payload 773 +* **Downlink Payload** 762 762 763 -**0A aa** àsame as AT+MOD=aa775 +**0A aa** ~-~-> same as AT+MOD=aa 764 764 765 765 766 766 767 -==== [[RS485 Debug Command>>path:#downlink_A8]](AT+CFGDEV) ====779 +==== **RS485 Debug Command (AT+CFGDEV)** ==== 768 768 769 769 This command is used to configure the RS485 or TTL sensors; they won’t be used during sampling. 770 770 771 -* AT Command 783 +* **AT Command** 772 772 773 -AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 785 +(% class="box infomessage" %) 786 +((( 787 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 788 +))) 774 774 775 775 m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command. 776 776 777 777 793 +* **Downlink Payload** 778 778 779 -* Downlink Payload 780 - 781 781 Format: A8 MM NN XX XX XX XX YY 782 782 783 783 Where: ... ... @@ -791,15 +791,15 @@ 791 791 792 792 To connect a Modbus Alarm with below commands. 793 793 794 -* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 808 +* The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 795 795 796 -* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 810 +* The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 797 797 798 798 So if user want to use downlink command to control to RS485 Alarm, he can use: 799 799 800 -**A8 01 06 0A 05 00 04 00 01 00**: to activate the RS485 Alarm 814 +(% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm 801 801 802 -**A8 01 06 0A 05 00 04 00 00 00**: to deactivate the RS485 Alarm 816 +(% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm 803 803 804 804 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output. 805 805 ... ... @@ -808,32 +808,35 @@ 808 808 809 809 Check TTL Sensor return: 810 810 811 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]825 +[[image:1654132684752-193.png]] 812 812 813 813 814 814 829 +==== **Set Payload version** ==== 815 815 816 -==== Set Payload version ==== 817 - 818 818 This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. 819 819 820 -* AT Command: 833 +* **AT Command:** 821 821 822 -AT+PAYVER: Set PAYVER field = 1 835 +(% class="box infomessage" %) 836 +((( 837 +**AT+PAYVER: Set PAYVER field = 1** 838 +))) 823 823 824 824 825 -* Downlink Payload: 841 +* **Downlink Payload:** 826 826 827 -0xAE 01 àSet PAYVER field = 0x01843 +**0xAE 01** ~-~-> Set PAYVER field = 0x01 828 828 829 -0xAE 0F àSet PAYVER field = 0x0F845 +**0xAE 0F** ~-~-> Set PAYVER field = 0x0F 830 830 831 831 832 -==== Set RS485 Sampling Commands ==== 833 833 849 +==== **Set RS485 Sampling Commands** ==== 850 + 834 834 AT+COMMANDx, AT+DATACUTx and AT+SEARCHx 835 835 836 -These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>> path:#polling_485]].853 +These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 837 837 838 838 839 839 * AT Command: ... ... @@ -1050,13 +1050,13 @@ 1050 1050 1051 1051 1052 1052 1053 -1. 1070 +1. 1054 1054 11. Buttons 1055 1055 1056 1056 |**Button**|**Feature** 1057 1057 |**RST**|Reboot RS485-BL 1058 1058 1059 -1. 1076 +1. 1060 1060 11. +3V3 Output 1061 1061 1062 1062 RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor. ... ... @@ -1074,7 +1074,7 @@ 1074 1074 By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time 1075 1075 1076 1076 1077 -1. 1094 +1. 1078 1078 11. +5V Output 1079 1079 1080 1080 RS485-BL has a Controllable +5V output, user can use this output to power external sensor. ... ... @@ -1094,13 +1094,13 @@ 1094 1094 1095 1095 1096 1096 1097 -1. 1114 +1. 1098 1098 11. LEDs 1099 1099 1100 1100 |**LEDs**|**Feature** 1101 1101 |**LED1**|Blink when device transmit a packet. 1102 1102 1103 -1. 1120 +1. 1104 1104 11. Switch Jumper 1105 1105 1106 1106 |**Switch Jumper**|**Feature** ... ... @@ -1146,7 +1146,7 @@ 1146 1146 1147 1147 1148 1148 1149 -1. 1166 +1. 1150 1150 11. Common AT Command Sequence 1151 1151 111. Multi-channel ABP mode (Use with SX1301/LG308) 1152 1152 ... ... @@ -1165,8 +1165,8 @@ 1165 1165 1166 1166 ATZ 1167 1167 1168 -1. 1169 -11. 1185 +1. 1186 +11. 1170 1170 111. Single-channel ABP mode (Use with LG01/LG02) 1171 1171 1172 1172 AT+FDR Reset Parameters to Factory Default, Keys Reserve ... ... @@ -1241,7 +1241,7 @@ 1241 1241 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] 1242 1242 1243 1243 1244 -1. 1261 +1. 1245 1245 11. How to change the LoRa Frequency Bands/Region? 1246 1246 1247 1247 User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download. ... ... @@ -1248,7 +1248,7 @@ 1248 1248 1249 1249 1250 1250 1251 -1. 1268 +1. 1252 1252 11. How many RS485-Slave can RS485-BL connects? 1253 1253 1254 1254 The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]]. ... ... @@ -1265,7 +1265,7 @@ 1265 1265 1266 1266 1267 1267 1268 -1. 1285 +1. 1269 1269 11. Why I can’t join TTN V3 in US915 /AU915 bands? 1270 1270 1271 1271 It might about the channels mapping. Please see for detail.
- 1654132684752-193.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.8 KB - Content