Last modified by Xiaoling on 2025/04/23 15:57

From version 29.33
edited by Xiaoling
on 2022/06/02 08:58
Change comment: There is no comment for this version
To version 29.31
edited by Xiaoling
on 2022/06/02 08:55
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -317,6 +317,7 @@
317 317  )))
318 318  
319 319  
320 +
320 320  === 3.3.2 Configure sensors ===
321 321  
322 322  (((
... ... @@ -464,6 +464,7 @@
464 464  * **c: define the position for valid value.  **
465 465  )))
466 466  
468 +
467 467  **Examples:**
468 468  
469 469  * Grab bytes:
... ... @@ -526,7 +526,7 @@
526 526  )))
527 527  
528 528  (((
529 -(% style="color:#037691" %)**Examples: AT+DATAUP=0**
531 +(% style="color:#4f81bd" %)**Examples: AT+DATAUP=0**
530 530  )))
531 531  
532 532  (((
... ... @@ -538,7 +538,7 @@
538 538  )))
539 539  
540 540  (((
541 -(% style="color:#4f81bd" %)**Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx**
543 +(% style="color:#4f81bd" %)Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx
542 542  )))
543 543  
544 544  (((
... ... @@ -548,11 +548,8 @@
548 548  [[image:1653272787040-634.png||height="515" width="719"]]
549 549  
550 550  
551 -
552 552  (((
553 -(% style="color:#037691" %)**Examples: AT+DATAUP=1**
554 -
555 -
554 +(% style="color:#4f81bd" %)**Examples: AT+DATAUP=1**
556 556  )))
557 557  
558 558  (((
... ... @@ -564,7 +564,7 @@
564 564  )))
565 565  
566 566  (((
567 -(% style="color:#4f81bd" %)**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**
566 +(% style="color:#4f81bd" %)Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA
568 568  )))
569 569  
570 570  1. (((
... ... @@ -731,15 +731,15 @@
731 731  
732 732  * **Sensor Related Commands**: These commands are special designed for RS485-BL.  User can see these commands below:
733 733  
734 -1.
735 -11.
733 +1.
734 +11.
736 736  111. Common Commands:
737 737  
738 738  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands]]
739 739  
740 740  
741 -1.
742 -11.
740 +1.
741 +11.
743 743  111. Sensor related commands:
744 744  
745 745  ==== Choose Device Type (RS485 or TTL) ====
... ... @@ -1045,13 +1045,13 @@
1045 1045  
1046 1046  
1047 1047  
1048 -1.
1047 +1.
1049 1049  11. Buttons
1050 1050  
1051 1051  |**Button**|**Feature**
1052 1052  |**RST**|Reboot RS485-BL
1053 1053  
1054 -1.
1053 +1.
1055 1055  11. +3V3 Output
1056 1056  
1057 1057  RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.
... ... @@ -1069,7 +1069,7 @@
1069 1069  By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time
1070 1070  
1071 1071  
1072 -1.
1071 +1.
1073 1073  11. +5V Output
1074 1074  
1075 1075  RS485-BL has a Controllable +5V output, user can use this output to power external sensor.
... ... @@ -1089,13 +1089,13 @@
1089 1089  
1090 1090  
1091 1091  
1092 -1.
1091 +1.
1093 1093  11. LEDs
1094 1094  
1095 1095  |**LEDs**|**Feature**
1096 1096  |**LED1**|Blink when device transmit a packet.
1097 1097  
1098 -1.
1097 +1.
1099 1099  11. Switch Jumper
1100 1100  
1101 1101  |**Switch Jumper**|**Feature**
... ... @@ -1141,7 +1141,7 @@
1141 1141  
1142 1142  
1143 1143  
1144 -1.
1143 +1.
1145 1145  11. Common AT Command Sequence
1146 1146  111. Multi-channel ABP mode (Use with SX1301/LG308)
1147 1147  
... ... @@ -1160,8 +1160,8 @@
1160 1160  
1161 1161  ATZ
1162 1162  
1163 -1.
1164 -11.
1162 +1.
1163 +11.
1165 1165  111. Single-channel ABP mode (Use with LG01/LG02)
1166 1166  
1167 1167  AT+FDR   Reset Parameters to Factory Default, Keys Reserve
... ... @@ -1236,7 +1236,7 @@
1236 1236  [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]]
1237 1237  
1238 1238  
1239 -1.
1238 +1.
1240 1240  11. How to change the LoRa Frequency Bands/Region?
1241 1241  
1242 1242  User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download.
... ... @@ -1243,7 +1243,7 @@
1243 1243  
1244 1244  
1245 1245  
1246 -1.
1245 +1.
1247 1247  11. How many RS485-Slave can RS485-BL connects?
1248 1248  
1249 1249  The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]].
... ... @@ -1260,7 +1260,7 @@
1260 1260  
1261 1261  
1262 1262  
1263 -1.
1262 +1.
1264 1264  11. Why I can’t join TTN V3 in US915 /AU915 bands?
1265 1265  
1266 1266  It might about the channels mapping. Please see for detail.