Last modified by Xiaoling on 2025/04/23 15:57

From version 29.33
edited by Xiaoling
on 2022/06/02 08:58
Change comment: There is no comment for this version
To version 29.19
edited by Xiaoling
on 2022/06/01 18:08
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -67,6 +67,7 @@
67 67  ** Idle: 6uA@3.3v
68 68  ** 20dB Transmit: 130mA@3.3v
69 69  
70 +
70 70  **Interface for Model:**
71 71  
72 72  * 1 x RS485 Interface
... ... @@ -76,6 +76,7 @@
76 76  * 1 x Interrupt Interface
77 77  * 1 x Controllable 5V output, max
78 78  
80 +
79 79  **LoRa Spec:**
80 80  
81 81  * Frequency Range:
... ... @@ -94,6 +94,7 @@
94 94  * 127 dB Dynamic Range RSSI.
95 95  * Automatic RF Sense and CAD with ultra-fast AFC. ​​​
96 96  
99 +
97 97  == 1.3 Features ==
98 98  
99 99  * LoRaWAN Class A & Class C protocol (default Class A)
... ... @@ -105,6 +105,7 @@
105 105  * Support Modbus protocol
106 106  * Support Interrupt uplink
107 107  
111 +
108 108  == 1.4 Applications ==
109 109  
110 110  * Smart Buildings & Home Automation
... ... @@ -114,6 +114,7 @@
114 114  * Smart Cities
115 115  * Smart Factory
116 116  
121 +
117 117  == 1.5 Firmware Change log ==
118 118  
119 119  [[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]]
... ... @@ -229,7 +229,6 @@
229 229  
230 230  [[image:1652953568895-172.png||height="232" width="724"]]
231 231  
232 -
233 233  == 3.3 Configure Commands to read data ==
234 234  
235 235  (((
... ... @@ -316,7 +316,6 @@
316 316  )))
317 317  )))
318 318  
319 -
320 320  === 3.3.2 Configure sensors ===
321 321  
322 322  (((
... ... @@ -337,9 +337,8 @@
337 337  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
338 338  )))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
339 339  
340 -Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]].
343 +Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>path:#AT_CFGDEV]].
341 341  
342 -
343 343  === 3.3.3 Configure read commands for each sampling ===
344 344  
345 345  (((
... ... @@ -437,7 +437,7 @@
437 437  
438 438  **Examples:**
439 439  
440 -1For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49
442 +1. For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49
441 441  
442 442  If we set AT+SEARCH1=1,1E 56 34.      (max 5 bytes for prefix)
443 443  
... ... @@ -445,7 +445,7 @@
445 445  
446 446  [[image:1653271044481-711.png]]
447 447  
448 -2)For a return string from AT+COMMAND1:  16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49
450 +1. For a return string from AT+COMMAND1:  16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49
449 449  
450 450  If we set AT+SEARCH1=2, 1E 56 34+31 00 49
451 451  
... ... @@ -464,18 +464,16 @@
464 464  * **c: define the position for valid value.  **
465 465  )))
466 466  
467 -**Examples:**
469 +Examples:
468 468  
469 469  * Grab bytes:
470 470  
471 471  [[image:1653271581490-837.png||height="313" width="722"]]
472 472  
473 -
474 474  * Grab a section.
475 475  
476 476  [[image:1653271648378-342.png||height="326" width="720"]]
477 477  
478 -
479 479  * Grab different sections.
480 480  
481 481  [[image:1653271657255-576.png||height="305" width="730"]]
... ... @@ -518,7 +518,6 @@
518 518  
519 519  [[image:1653271763403-806.png]]
520 520  
521 -
522 522  === 3.3.4 Compose the uplink payload ===
523 523  
524 524  (((
... ... @@ -526,7 +526,7 @@
526 526  )))
527 527  
528 528  (((
529 -(% style="color:#037691" %)**Examples: AT+DATAUP=0**
528 +(% style="color:#4f81bd" %)**Examples: AT+DATAUP=0**
530 530  )))
531 531  
532 532  (((
... ... @@ -538,7 +538,7 @@
538 538  )))
539 539  
540 540  (((
541 -(% style="color:#4f81bd" %)**Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx**
540 +(% style="color:#4f81bd" %)Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx
542 542  )))
543 543  
544 544  (((
... ... @@ -547,12 +547,8 @@
547 547  
548 548  [[image:1653272787040-634.png||height="515" width="719"]]
549 549  
550 -
551 -
552 552  (((
553 -(% style="color:#037691" %)**Examples: AT+DATAUP=1**
554 -
555 -
550 +(% style="color:#4f81bd" %)**Examples: AT+DATAUP=1**
556 556  )))
557 557  
558 558  (((
... ... @@ -564,7 +564,7 @@
564 564  )))
565 565  
566 566  (((
567 -(% style="color:#4f81bd" %)**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**
562 +(% style="color:#4f81bd" %)Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA
568 568  )))
569 569  
570 570  1. (((
... ... @@ -731,15 +731,15 @@
731 731  
732 732  * **Sensor Related Commands**: These commands are special designed for RS485-BL.  User can see these commands below:
733 733  
734 -1.
735 -11.
729 +1.
730 +11.
736 736  111. Common Commands:
737 737  
738 738  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands]]
739 739  
740 740  
741 -1.
742 -11.
736 +1.
737 +11.
743 743  111. Sensor related commands:
744 744  
745 745  ==== Choose Device Type (RS485 or TTL) ====
... ... @@ -1045,13 +1045,13 @@
1045 1045  
1046 1046  
1047 1047  
1048 -1.
1043 +1.
1049 1049  11. Buttons
1050 1050  
1051 1051  |**Button**|**Feature**
1052 1052  |**RST**|Reboot RS485-BL
1053 1053  
1054 -1.
1049 +1.
1055 1055  11. +3V3 Output
1056 1056  
1057 1057  RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.
... ... @@ -1069,7 +1069,7 @@
1069 1069  By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time
1070 1070  
1071 1071  
1072 -1.
1067 +1.
1073 1073  11. +5V Output
1074 1074  
1075 1075  RS485-BL has a Controllable +5V output, user can use this output to power external sensor.
... ... @@ -1089,13 +1089,13 @@
1089 1089  
1090 1090  
1091 1091  
1092 -1.
1087 +1.
1093 1093  11. LEDs
1094 1094  
1095 1095  |**LEDs**|**Feature**
1096 1096  |**LED1**|Blink when device transmit a packet.
1097 1097  
1098 -1.
1093 +1.
1099 1099  11. Switch Jumper
1100 1100  
1101 1101  |**Switch Jumper**|**Feature**
... ... @@ -1141,7 +1141,7 @@
1141 1141  
1142 1142  
1143 1143  
1144 -1.
1139 +1.
1145 1145  11. Common AT Command Sequence
1146 1146  111. Multi-channel ABP mode (Use with SX1301/LG308)
1147 1147  
... ... @@ -1160,8 +1160,8 @@
1160 1160  
1161 1161  ATZ
1162 1162  
1163 -1.
1164 -11.
1158 +1.
1159 +11.
1165 1165  111. Single-channel ABP mode (Use with LG01/LG02)
1166 1166  
1167 1167  AT+FDR   Reset Parameters to Factory Default, Keys Reserve
... ... @@ -1236,7 +1236,7 @@
1236 1236  [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]]
1237 1237  
1238 1238  
1239 -1.
1234 +1.
1240 1240  11. How to change the LoRa Frequency Bands/Region?
1241 1241  
1242 1242  User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download.
... ... @@ -1243,7 +1243,7 @@
1243 1243  
1244 1244  
1245 1245  
1246 -1.
1241 +1.
1247 1247  11. How many RS485-Slave can RS485-BL connects?
1248 1248  
1249 1249  The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]].
... ... @@ -1260,7 +1260,7 @@
1260 1260  
1261 1261  
1262 1262  
1263 -1.
1258 +1.
1264 1264  11. Why I can’t join TTN V3 in US915 /AU915 bands?
1265 1265  
1266 1266  It might about the channels mapping. Please see for detail.