Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -25,19 +25,19 @@ 25 25 ))) 26 26 27 27 ((( 28 -The Dragino RS485-BL is a (% style="color:blue" %)**RS485 / UART to LoRaWAN Converter**(%%)for Internet of Things solutions. User can connect RS485 or UART sensor to RS485-BL converter, and configure RS485-BL to periodically read sensor data and upload via LoRaWAN network to IoT server.28 +The Dragino RS485-BL is a **RS485 / UART to LoRaWAN Converter** for Internet of Things solutions. User can connect RS485 or UART sensor to RS485-BL converter, and configure RS485-BL to periodically read sensor data and upload via LoRaWAN network to IoT server. 29 29 ))) 30 30 31 31 ((( 32 -RS485-BL can interface to RS485 sensor, 3.3v/5v UART sensor or interrupt sensor. RS485-BL provides (% style="color:blue" %)**a 3.3v output**(%%)and**(% style="color:blue" %)a 5v output(%%)** to power external sensors. Both output voltages are controllable to minimize the total system power consumption.32 +RS485-BL can interface to RS485 sensor, 3.3v/5v UART sensor or interrupt sensor. RS485-BL provides **a 3.3v output** and** a 5v output** to power external sensors. Both output voltages are controllable to minimize the total system power consumption. 33 33 ))) 34 34 35 35 ((( 36 -RS485-BL is IP67 (% style="color:blue" %)**waterproof**(%%)and powered by(% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use for several years.36 +RS485-BL is IP67 **waterproof** and powered by **8500mAh Li-SOCI2 battery**, it is designed for long term use for several years. 37 37 ))) 38 38 39 39 ((( 40 -RS485-BL runs standard (% style="color:blue" %)**LoRaWAN 1.0.3 in Class A**(%%). It can reach long transfer range and easy to integrate with LoRaWAN compatible gateway and IoT server.40 +RS485-BL runs standard **LoRaWAN 1.0.3 in Class A**. It can reach long transfer range and easy to integrate with LoRaWAN compatible gateway and IoT server. 41 41 ))) 42 42 43 43 ((( ... ... @@ -54,11 +54,8 @@ 54 54 55 55 [[image:1652953304999-717.png||height="424" width="733"]] 56 56 57 - 58 - 59 59 == 1.2 Specifications == 60 60 61 - 62 62 **Hardware System:** 63 63 64 64 * STM32L072CZT6 MCU ... ... @@ -65,6 +65,8 @@ 65 65 * SX1276/78 Wireless Chip 66 66 * Power Consumption (exclude RS485 device): 67 67 ** Idle: 6uA@3.3v 65 + 66 +* 68 68 ** 20dB Transmit: 130mA@3.3v 69 69 70 70 **Interface for Model:** ... ... @@ -94,6 +94,8 @@ 94 94 * 127 dB Dynamic Range RSSI. 95 95 * Automatic RF Sense and CAD with ultra-fast AFC. 96 96 96 + 97 + 97 97 == 1.3 Features == 98 98 99 99 * LoRaWAN Class A & Class C protocol (default Class A) ... ... @@ -105,6 +105,8 @@ 105 105 * Support Modbus protocol 106 106 * Support Interrupt uplink 107 107 109 + 110 + 108 108 == 1.4 Applications == 109 109 110 110 * Smart Buildings & Home Automation ... ... @@ -114,6 +114,8 @@ 114 114 * Smart Cities 115 115 * Smart Factory 116 116 120 + 121 + 117 117 == 1.5 Firmware Change log == 118 118 119 119 [[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]] ... ... @@ -122,8 +122,6 @@ 122 122 == 1.6 Hardware Change log == 123 123 124 124 ((( 125 - 126 - 127 127 v1.4 128 128 ))) 129 129 ... ... @@ -206,6 +206,8 @@ 206 206 ))) 207 207 208 208 212 + 213 + 209 209 [[image:image-20220519174512-1.png]] 210 210 211 211 [[image:image-20220519174512-2.png||height="328" width="731"]] ... ... @@ -229,7 +229,6 @@ 229 229 230 230 [[image:1652953568895-172.png||height="232" width="724"]] 231 231 232 - 233 233 == 3.3 Configure Commands to read data == 234 234 235 235 ((( ... ... @@ -316,8 +316,6 @@ 316 316 ))) 317 317 ))) 318 318 319 - 320 - 321 321 === 3.3.2 Configure sensors === 322 322 323 323 ((( ... ... @@ -338,9 +338,8 @@ 338 338 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 339 339 )))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 340 340 341 -Detail of AT+CFGDEV command see [[AT+CFGDEV detail>> ||anchor="HRS485DebugCommand28AT2BCFGDEV29"]].343 +Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>path:#AT_CFGDEV]]. 342 342 343 - 344 344 === 3.3.3 Configure read commands for each sampling === 345 345 346 346 ((( ... ... @@ -438,7 +438,7 @@ 438 438 439 439 **Examples:** 440 440 441 -1 )For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49442 +1. For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49 442 442 443 443 If we set AT+SEARCH1=1,1E 56 34. (max 5 bytes for prefix) 444 444 ... ... @@ -446,7 +446,7 @@ 446 446 447 447 [[image:1653271044481-711.png]] 448 448 449 - 2)For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49450 +1. For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49 450 450 451 451 If we set AT+SEARCH1=2, 1E 56 34+31 00 49 452 452 ... ... @@ -465,19 +465,16 @@ 465 465 * **c: define the position for valid value. ** 466 466 ))) 467 467 469 +Examples: 468 468 469 -**Examples:** 470 - 471 471 * Grab bytes: 472 472 473 473 [[image:1653271581490-837.png||height="313" width="722"]] 474 474 475 - 476 476 * Grab a section. 477 477 478 478 [[image:1653271648378-342.png||height="326" width="720"]] 479 479 480 - 481 481 * Grab different sections. 482 482 483 483 [[image:1653271657255-576.png||height="305" width="730"]] ... ... @@ -520,7 +520,6 @@ 520 520 521 521 [[image:1653271763403-806.png]] 522 522 523 - 524 524 === 3.3.4 Compose the uplink payload === 525 525 526 526 ((( ... ... @@ -549,11 +549,8 @@ 549 549 550 550 [[image:1653272787040-634.png||height="515" width="719"]] 551 551 552 - 553 553 ((( 554 554 (% style="color:#4f81bd" %)**Examples: AT+DATAUP=1** 555 - 556 - 557 557 ))) 558 558 559 559 ((( ... ... @@ -732,15 +732,15 @@ 732 732 733 733 * **Sensor Related Commands**: These commands are special designed for RS485-BL. User can see these commands below: 734 734 735 -1. 736 -11. 729 +1. 730 +11. 737 737 111. Common Commands: 738 738 739 739 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands]] 740 740 741 741 742 -1. 743 -11. 736 +1. 737 +11. 744 744 111. Sensor related commands: 745 745 746 746 ==== Choose Device Type (RS485 or TTL) ==== ... ... @@ -1046,13 +1046,13 @@ 1046 1046 1047 1047 1048 1048 1049 -1. 1043 +1. 1050 1050 11. Buttons 1051 1051 1052 1052 |**Button**|**Feature** 1053 1053 |**RST**|Reboot RS485-BL 1054 1054 1055 -1. 1049 +1. 1056 1056 11. +3V3 Output 1057 1057 1058 1058 RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor. ... ... @@ -1070,7 +1070,7 @@ 1070 1070 By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time 1071 1071 1072 1072 1073 -1. 1067 +1. 1074 1074 11. +5V Output 1075 1075 1076 1076 RS485-BL has a Controllable +5V output, user can use this output to power external sensor. ... ... @@ -1090,13 +1090,13 @@ 1090 1090 1091 1091 1092 1092 1093 -1. 1087 +1. 1094 1094 11. LEDs 1095 1095 1096 1096 |**LEDs**|**Feature** 1097 1097 |**LED1**|Blink when device transmit a packet. 1098 1098 1099 -1. 1093 +1. 1100 1100 11. Switch Jumper 1101 1101 1102 1102 |**Switch Jumper**|**Feature** ... ... @@ -1142,7 +1142,7 @@ 1142 1142 1143 1143 1144 1144 1145 -1. 1139 +1. 1146 1146 11. Common AT Command Sequence 1147 1147 111. Multi-channel ABP mode (Use with SX1301/LG308) 1148 1148 ... ... @@ -1161,8 +1161,8 @@ 1161 1161 1162 1162 ATZ 1163 1163 1164 -1. 1165 -11. 1158 +1. 1159 +11. 1166 1166 111. Single-channel ABP mode (Use with LG01/LG02) 1167 1167 1168 1168 AT+FDR Reset Parameters to Factory Default, Keys Reserve ... ... @@ -1237,7 +1237,7 @@ 1237 1237 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] 1238 1238 1239 1239 1240 -1. 1234 +1. 1241 1241 11. How to change the LoRa Frequency Bands/Region? 1242 1242 1243 1243 User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download. ... ... @@ -1244,7 +1244,7 @@ 1244 1244 1245 1245 1246 1246 1247 -1. 1241 +1. 1248 1248 11. How many RS485-Slave can RS485-BL connects? 1249 1249 1250 1250 The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]]. ... ... @@ -1261,7 +1261,7 @@ 1261 1261 1262 1262 1263 1263 1264 -1. 1258 +1. 1265 1265 11. Why I can’t join TTN V3 in US915 /AU915 bands? 1266 1266 1267 1267 It might about the channels mapping. Please see for detail.