Last modified by Xiaoling on 2025/04/23 15:57

From version 29.30
edited by Xiaoling
on 2022/06/02 08:54
Change comment: There is no comment for this version
To version 29.40
edited by Xiaoling
on 2022/06/02 09:10
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -316,8 +316,6 @@
316 316  )))
317 317  )))
318 318  
319 -
320 -
321 321  === 3.3.2 Configure sensors ===
322 322  
323 323  (((
... ... @@ -465,7 +465,6 @@
465 465  * **c: define the position for valid value.  **
466 466  )))
467 467  
468 -
469 469  **Examples:**
470 470  
471 471  * Grab bytes:
... ... @@ -528,7 +528,7 @@
528 528  )))
529 529  
530 530  (((
531 -(% style="color:#4f81bd" %)**Examples: AT+DATAUP=0**
528 +(% style="color:#037691" %)**Examples: AT+DATAUP=0**
532 532  )))
533 533  
534 534  (((
... ... @@ -540,7 +540,7 @@
540 540  )))
541 541  
542 542  (((
543 -(% style="color:#4f81bd" %)Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx
540 +(% style="color:#4f81bd" %)**Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx**
544 544  )))
545 545  
546 546  (((
... ... @@ -549,8 +549,12 @@
549 549  
550 550  [[image:1653272787040-634.png||height="515" width="719"]]
551 551  
549 +
550 +
552 552  (((
553 -(% style="color:#4f81bd" %)**Examples: AT+DATAUP=1**
552 +(% style="color:#037691" %)**Examples: AT+DATAUP=1**
553 +
554 +
554 554  )))
555 555  
556 556  (((
... ... @@ -562,7 +562,7 @@
562 562  )))
563 563  
564 564  (((
565 -(% style="color:#4f81bd" %)Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA
566 +(% style="color:#4f81bd" %)**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**
566 566  )))
567 567  
568 568  1. (((
... ... @@ -585,6 +585,7 @@
585 585  
586 586  So totally there will be 3 uplinks for this sampling, each uplink includes 6 bytes DATA
587 587  
589 +
588 588  DATA1=RETURN1 Valid Value = (% style="background-color:#4f81bd; color:white" %) 20 20 0a 33 90 41
589 589  
590 590  DATA2=1^^st^^ ~~ 6^^th^^ byte of Valid value of RETURN10= (% style="background-color:#4f81bd; color:white" %)02 aa 05 81 0a 20
... ... @@ -591,10 +591,12 @@
591 591  
592 592  DATA3=7^^th^^ ~~ 11^^th^^ bytes of Valid value of RETURN10 =(% style="background-color:#4f81bd; color:white" %) 20 20 20 2d 30
593 593  
596 +
594 594  Below are the uplink payloads:
595 595  
596 596  [[image:1653272901032-107.png]]
597 597  
601 +
598 598  (% style="color:red" %)Notice: the Max bytes is according to the max support bytes in different Frequency Bands for lowest SF. As below:
599 599  
600 600   ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink ( so 51 -5 = 46 max valid date)
... ... @@ -605,6 +605,8 @@
605 605  
606 606   ~* For all other bands: max 51 bytes for each uplink  ( so 51 -5 = 46 max valid date).
607 607  
612 +
613 +
608 608  === 3.3.5 Uplink on demand ===
609 609  
610 610  (((
... ... @@ -621,6 +621,8 @@
621 621  
622 622  (((
623 623  **0xA8 command**: Send a command to RS485-BL and uplink the output from sensors.
630 +
631 +
624 624  )))
625 625  
626 626  === 3.3.6 Uplink on Interrupt ===
... ... @@ -629,6 +629,7 @@
629 629  
630 630  [[image:1653273818896-432.png]]
631 631  
640 +
632 632  (((
633 633  AT+INTMOD=0  Disable Interrupt
634 634  )))
... ... @@ -643,6 +643,8 @@
643 643  
644 644  (((
645 645  AT+INTMOD=3  Interrupt trigger by rising edge.
655 +
656 +
646 646  )))
647 647  
648 648  == 3.4 Uplink Payload ==
... ... @@ -670,47 +670,49 @@
670 670  Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
671 671  
672 672  (((
673 -function Decoder(bytes, port) {
684 +{{{function Decoder(bytes, port) {}}}
674 674  )))
675 675  
676 676  (((
677 -~/~/Payload Formats of RS485-BL Deceive
688 +{{{//Payload Formats of RS485-BL Deceive}}}
678 678  )))
679 679  
680 680  (((
681 -return {
692 +{{{return {}}}
682 682  )))
683 683  
684 684  (((
685 - ~/~/Battery,units:V
696 +{{{ //Battery,units:V}}}
686 686  )))
687 687  
688 688  (((
689 - BatV:((bytes[0]<<8 | bytes[1])&0x7fff)/1000,
700 +{{{ BatV:((bytes[0]<<8 | bytes[1])&0x7fff)/1000,}}}
690 690  )))
691 691  
692 692  (((
693 - ~/~/GPIO_EXTI 
704 +{{{ //GPIO_EXTI }}}
694 694  )))
695 695  
696 696  (((
697 - EXTI_Trigger:(bytes[0] & 0x80)? "TRUE":"FALSE",
708 +{{{ EXTI_Trigger:(bytes[0] & 0x80)? "TRUE":"FALSE",}}}
698 698  )))
699 699  
700 700  (((
701 - ~/~/payload of version
712 +{{{ //payload of version}}}
702 702  )))
703 703  
704 704  (((
705 - Pay_ver:bytes[2],
716 +{{{ Pay_ver:bytes[2],}}}
706 706  )))
707 707  
708 708  (((
709 - };
720 +{{{ }; }}}
710 710  )))
711 711  
712 712  (((
713 - }
724 +}
725 +
726 +
714 714  )))
715 715  
716 716  (((
... ... @@ -719,27 +719,26 @@
719 719  
720 720  [[image:1653274001211-372.png||height="192" width="732"]]
721 721  
735 +
722 722  == 3.5 Configure RS485-BL via AT or Downlink ==
723 723  
724 -User can configure RS485-BL via [[AT Commands >>path:#_​Using_the_AT]]or LoRaWAN Downlink Commands
738 +User can configure RS485-BL via AT Commands or LoRaWAN Downlink Commands
725 725  
726 726  There are two kinds of Commands:
727 727  
728 -* **Common Commands**: They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands
742 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
729 729  
730 -* **Sensor Related Commands**: These commands are special designed for RS485-BL.  User can see these commands below:
744 +* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
731 731  
732 -1.
733 -11.
734 -111. Common Commands:
735 735  
736 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands]]
737 737  
748 +=== 3.5.1 Common Commands: ===
738 738  
739 -1.
740 -11.
741 -111. Sensor related commands:
750 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
742 742  
752 +
753 +=== 3.5.2 Sensor related commands: ===
754 +
743 743  ==== Choose Device Type (RS485 or TTL) ====
744 744  
745 745  RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect.