Last modified by Xiaoling on 2025/04/23 15:57

From version 29.28
edited by Xiaoling
on 2022/06/02 08:54
Change comment: There is no comment for this version
To version 29.41
edited by Xiaoling
on 2022/06/02 09:12
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -316,8 +316,6 @@
316 316  )))
317 317  )))
318 318  
319 -
320 -
321 321  === 3.3.2 Configure sensors ===
322 322  
323 323  (((
... ... @@ -465,7 +465,6 @@
465 465  * **c: define the position for valid value.  **
466 466  )))
467 467  
468 -
469 469  **Examples:**
470 470  
471 471  * Grab bytes:
... ... @@ -477,6 +477,7 @@
477 477  
478 478  [[image:1653271648378-342.png||height="326" width="720"]]
479 479  
477 +
480 480  * Grab different sections.
481 481  
482 482  [[image:1653271657255-576.png||height="305" width="730"]]
... ... @@ -519,6 +519,7 @@
519 519  
520 520  [[image:1653271763403-806.png]]
521 521  
520 +
522 522  === 3.3.4 Compose the uplink payload ===
523 523  
524 524  (((
... ... @@ -526,7 +526,7 @@
526 526  )))
527 527  
528 528  (((
529 -(% style="color:#4f81bd" %)**Examples: AT+DATAUP=0**
528 +(% style="color:#037691" %)**Examples: AT+DATAUP=0**
530 530  )))
531 531  
532 532  (((
... ... @@ -538,7 +538,7 @@
538 538  )))
539 539  
540 540  (((
541 -(% style="color:#4f81bd" %)Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx
540 +(% style="color:#4f81bd" %)**Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx**
542 542  )))
543 543  
544 544  (((
... ... @@ -547,8 +547,12 @@
547 547  
548 548  [[image:1653272787040-634.png||height="515" width="719"]]
549 549  
549 +
550 +
550 550  (((
551 -(% style="color:#4f81bd" %)**Examples: AT+DATAUP=1**
552 +(% style="color:#037691" %)**Examples: AT+DATAUP=1**
553 +
554 +
552 552  )))
553 553  
554 554  (((
... ... @@ -560,7 +560,7 @@
560 560  )))
561 561  
562 562  (((
563 -(% style="color:#4f81bd" %)Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA
566 +(% style="color:#4f81bd" %)**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**
564 564  )))
565 565  
566 566  1. (((
... ... @@ -583,6 +583,7 @@
583 583  
584 584  So totally there will be 3 uplinks for this sampling, each uplink includes 6 bytes DATA
585 585  
589 +
586 586  DATA1=RETURN1 Valid Value = (% style="background-color:#4f81bd; color:white" %) 20 20 0a 33 90 41
587 587  
588 588  DATA2=1^^st^^ ~~ 6^^th^^ byte of Valid value of RETURN10= (% style="background-color:#4f81bd; color:white" %)02 aa 05 81 0a 20
... ... @@ -589,10 +589,12 @@
589 589  
590 590  DATA3=7^^th^^ ~~ 11^^th^^ bytes of Valid value of RETURN10 =(% style="background-color:#4f81bd; color:white" %) 20 20 20 2d 30
591 591  
596 +
592 592  Below are the uplink payloads:
593 593  
594 594  [[image:1653272901032-107.png]]
595 595  
601 +
596 596  (% style="color:red" %)Notice: the Max bytes is according to the max support bytes in different Frequency Bands for lowest SF. As below:
597 597  
598 598   ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink ( so 51 -5 = 46 max valid date)
... ... @@ -603,6 +603,8 @@
603 603  
604 604   ~* For all other bands: max 51 bytes for each uplink  ( so 51 -5 = 46 max valid date).
605 605  
612 +
613 +
606 606  === 3.3.5 Uplink on demand ===
607 607  
608 608  (((
... ... @@ -619,6 +619,8 @@
619 619  
620 620  (((
621 621  **0xA8 command**: Send a command to RS485-BL and uplink the output from sensors.
630 +
631 +
622 622  )))
623 623  
624 624  === 3.3.6 Uplink on Interrupt ===
... ... @@ -627,6 +627,7 @@
627 627  
628 628  [[image:1653273818896-432.png]]
629 629  
640 +
630 630  (((
631 631  AT+INTMOD=0  Disable Interrupt
632 632  )))
... ... @@ -641,6 +641,8 @@
641 641  
642 642  (((
643 643  AT+INTMOD=3  Interrupt trigger by rising edge.
655 +
656 +
644 644  )))
645 645  
646 646  == 3.4 Uplink Payload ==
... ... @@ -668,47 +668,49 @@
668 668  Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
669 669  
670 670  (((
671 -function Decoder(bytes, port) {
684 +{{{function Decoder(bytes, port) {}}}
672 672  )))
673 673  
674 674  (((
675 -~/~/Payload Formats of RS485-BL Deceive
688 +{{{//Payload Formats of RS485-BL Deceive}}}
676 676  )))
677 677  
678 678  (((
679 -return {
692 +{{{return {}}}
680 680  )))
681 681  
682 682  (((
683 - ~/~/Battery,units:V
696 +{{{ //Battery,units:V}}}
684 684  )))
685 685  
686 686  (((
687 - BatV:((bytes[0]<<8 | bytes[1])&0x7fff)/1000,
700 +{{{ BatV:((bytes[0]<<8 | bytes[1])&0x7fff)/1000,}}}
688 688  )))
689 689  
690 690  (((
691 - ~/~/GPIO_EXTI 
704 +{{{ //GPIO_EXTI }}}
692 692  )))
693 693  
694 694  (((
695 - EXTI_Trigger:(bytes[0] & 0x80)? "TRUE":"FALSE",
708 +{{{ EXTI_Trigger:(bytes[0] & 0x80)? "TRUE":"FALSE",}}}
696 696  )))
697 697  
698 698  (((
699 - ~/~/payload of version
712 +{{{ //payload of version}}}
700 700  )))
701 701  
702 702  (((
703 - Pay_ver:bytes[2],
716 +{{{ Pay_ver:bytes[2],}}}
704 704  )))
705 705  
706 706  (((
707 - };
720 +{{{ }; }}}
708 708  )))
709 709  
710 710  (((
711 - }
724 +}
725 +
726 +
712 712  )))
713 713  
714 714  (((
... ... @@ -717,29 +717,30 @@
717 717  
718 718  [[image:1653274001211-372.png||height="192" width="732"]]
719 719  
735 +
720 720  == 3.5 Configure RS485-BL via AT or Downlink ==
721 721  
722 -User can configure RS485-BL via [[AT Commands >>path:#_​Using_the_AT]]or LoRaWAN Downlink Commands
738 +User can configure RS485-BL via AT Commands or LoRaWAN Downlink Commands
723 723  
724 724  There are two kinds of Commands:
725 725  
726 -* **Common Commands**: They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands
742 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
727 727  
728 -* **Sensor Related Commands**: These commands are special designed for RS485-BL.  User can see these commands below:
744 +* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
729 729  
730 -1.
731 -11.
732 -111. Common Commands:
733 733  
734 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands]]
747 +=== 3.5.1 Common Commands: ===
735 735  
749 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
736 736  
737 -1.
738 -11.
739 -111. Sensor related commands:
740 740  
741 -==== Choose Device Type (RS485 or TTL) ====
752 +=== 3.5.2 Sensor related commands: ===
742 742  
754 +(% class="wikigeneratedid" %)
755 +==== ====
756 +
757 +==== **Choose Device Type (RS485 or TTL)** ====
758 +
743 743  RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect.
744 744  
745 745  * AT Command