Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -67,7 +67,6 @@ 67 67 ** Idle: 6uA@3.3v 68 68 ** 20dB Transmit: 130mA@3.3v 69 69 70 - 71 71 **Interface for Model:** 72 72 73 73 * 1 x RS485 Interface ... ... @@ -77,7 +77,6 @@ 77 77 * 1 x Interrupt Interface 78 78 * 1 x Controllable 5V output, max 79 79 80 - 81 81 **LoRa Spec:** 82 82 83 83 * Frequency Range: ... ... @@ -96,7 +96,6 @@ 96 96 * 127 dB Dynamic Range RSSI. 97 97 * Automatic RF Sense and CAD with ultra-fast AFC. 98 98 99 - 100 100 == 1.3 Features == 101 101 102 102 * LoRaWAN Class A & Class C protocol (default Class A) ... ... @@ -108,7 +108,6 @@ 108 108 * Support Modbus protocol 109 109 * Support Interrupt uplink 110 110 111 - 112 112 == 1.4 Applications == 113 113 114 114 * Smart Buildings & Home Automation ... ... @@ -118,7 +118,6 @@ 118 118 * Smart Cities 119 119 * Smart Factory 120 120 121 - 122 122 == 1.5 Firmware Change log == 123 123 124 124 [[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]] ... ... @@ -343,7 +343,7 @@ 343 343 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 344 344 )))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 345 345 346 -Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29]]. 341 +Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]]. 347 347 348 348 349 349 === 3.3.3 Configure read commands for each sampling === ... ... @@ -443,7 +443,7 @@ 443 443 444 444 **Examples:** 445 445 446 -1 .For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49441 +1)For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49 447 447 448 448 If we set AT+SEARCH1=1,1E 56 34. (max 5 bytes for prefix) 449 449 ... ... @@ -451,7 +451,7 @@ 451 451 452 452 [[image:1653271044481-711.png]] 453 453 454 - 1.For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49449 +2)For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49 455 455 456 456 If we set AT+SEARCH1=2, 1E 56 34+31 00 49 457 457 ... ... @@ -470,12 +470,14 @@ 470 470 * **c: define the position for valid value. ** 471 471 ))) 472 472 473 -Examples: 474 474 469 +**Examples:** 470 + 475 475 * Grab bytes: 476 476 477 477 [[image:1653271581490-837.png||height="313" width="722"]] 478 478 475 + 479 479 * Grab a section. 480 480 481 481 [[image:1653271648378-342.png||height="326" width="720"]]