Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -7,12 +7,15 @@ 7 7 **RS485-BL – Waterproof RS485 to LoRaWAN Converter User Manual** 8 8 9 9 10 + 10 10 **Table of Contents:** 11 11 13 +{{toc/}} 12 12 13 13 14 14 15 15 18 + 16 16 = 1.Introduction = 17 17 18 18 == 1.1 What is RS485-BL RS485 to LoRaWAN Converter == ... ... @@ -22,19 +22,19 @@ 22 22 ))) 23 23 24 24 ((( 25 -The Dragino RS485-BL is a **RS485 / UART to LoRaWAN Converter** for Internet of Things solutions. User can connect RS485 or UART sensor to RS485-BL converter, and configure RS485-BL to periodically read sensor data and upload via LoRaWAN network to IoT server. 28 +The Dragino RS485-BL is a (% style="color:blue" %)**RS485 / UART to LoRaWAN Converter**(%%) for Internet of Things solutions. User can connect RS485 or UART sensor to RS485-BL converter, and configure RS485-BL to periodically read sensor data and upload via LoRaWAN network to IoT server. 26 26 ))) 27 27 28 28 ((( 29 -RS485-BL can interface to RS485 sensor, 3.3v/5v UART sensor or interrupt sensor. RS485-BL provides **a 3.3v output** and** a 5v output** to power external sensors. Both output voltages are controllable to minimize the total system power consumption. 32 +RS485-BL can interface to RS485 sensor, 3.3v/5v UART sensor or interrupt sensor. RS485-BL provides (% style="color:blue" %)**a 3.3v output**(%%) and** (% style="color:blue" %)a 5v output(%%)** to power external sensors. Both output voltages are controllable to minimize the total system power consumption. 30 30 ))) 31 31 32 32 ((( 33 -RS485-BL is IP67 **waterproof** and powered by **8500mAh Li-SOCI2 battery**, it is designed for long term use for several years. 36 +RS485-BL is IP67 (% style="color:blue" %)**waterproof**(%%) and powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use for several years. 34 34 ))) 35 35 36 36 ((( 37 -RS485-BL runs standard **LoRaWAN 1.0.3 in Class A**. It can reach long transfer range and easy to integrate with LoRaWAN compatible gateway and IoT server. 40 +RS485-BL runs standard (% style="color:blue" %)**LoRaWAN 1.0.3 in Class A**(%%). It can reach long transfer range and easy to integrate with LoRaWAN compatible gateway and IoT server. 38 38 ))) 39 39 40 40 ((( ... ... @@ -51,8 +51,11 @@ 51 51 52 52 [[image:1652953304999-717.png||height="424" width="733"]] 53 53 57 + 58 + 54 54 == 1.2 Specifications == 55 55 61 + 56 56 **Hardware System:** 57 57 58 58 * STM32L072CZT6 MCU ... ... @@ -59,8 +59,6 @@ 59 59 * SX1276/78 Wireless Chip 60 60 * Power Consumption (exclude RS485 device): 61 61 ** Idle: 6uA@3.3v 62 - 63 -* 64 64 ** 20dB Transmit: 130mA@3.3v 65 65 66 66 **Interface for Model:** ... ... @@ -114,9 +114,12 @@ 114 114 115 115 [[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]] 116 116 121 + 117 117 == 1.6 Hardware Change log == 118 118 119 119 ((( 125 + 126 + 120 120 v1.4 121 121 ))) 122 122 ... ... @@ -140,6 +140,8 @@ 140 140 141 141 ((( 142 142 Release version 150 + 151 + 143 143 ))) 144 144 145 145 = 2. Pin mapping and Power ON Device = ... ... @@ -153,6 +153,7 @@ 153 153 154 154 The Left TXD and RXD are TTL interface for external sensor. TTL level is controlled by 3.3/5v Jumper. 155 155 165 + 156 156 = 3. Operation Mode = 157 157 158 158 == 3.1 How it works? == ... ... @@ -159,6 +159,8 @@ 159 159 160 160 ((( 161 161 The RS485-BL is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the RS485-BL. It will auto join the network via OTAA. 172 + 173 + 162 162 ))) 163 163 164 164 == 3.2 Example to join LoRaWAN network == ... ... @@ -194,8 +194,6 @@ 194 194 ))) 195 195 196 196 197 - 198 - 199 199 [[image:image-20220519174512-1.png]] 200 200 201 201 [[image:image-20220519174512-2.png||height="328" width="731"]] ... ... @@ -219,10 +219,13 @@ 219 219 220 220 [[image:1652953568895-172.png||height="232" width="724"]] 221 221 232 + 222 222 == 3.3 Configure Commands to read data == 223 223 224 224 ((( 225 -There are plenty of RS485 and TTL level devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-BL supports flexible command set. User can use [[AT Commands or LoRaWAN Downlink>>path:#AT_COMMAND]] Command to configure how RS485-BL should read the sensor and how to handle the return from RS485 or TTL sensors. 236 +There are plenty of RS485 and TTL level devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-BL supports flexible command set. User can use [[AT Commands or LoRaWAN Downlink>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] Command to configure how RS485-BL should read the sensor and how to handle the return from RS485 or TTL sensors. 237 + 238 + 226 226 ))) 227 227 228 228 === 3.3.1 onfigure UART settings for RS485 or TTL communication === ... ... @@ -323,8 +323,9 @@ 323 323 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 324 324 )))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 325 325 326 -Detail of AT+CFGDEV command see [[AT+CFGDEV detail>> path:#AT_CFGDEV]].339 +Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]]. 327 327 341 + 328 328 === 3.3.3 Configure read commands for each sampling === 329 329 330 330 ((( ... ... @@ -422,7 +422,7 @@ 422 422 423 423 **Examples:** 424 424 425 -1 .For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49439 +1)For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49 426 426 427 427 If we set AT+SEARCH1=1,1E 56 34. (max 5 bytes for prefix) 428 428 ... ... @@ -430,7 +430,7 @@ 430 430 431 431 [[image:1653271044481-711.png]] 432 432 433 - 1.For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49447 +2)For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49 434 434 435 435 If we set AT+SEARCH1=2, 1E 56 34+31 00 49 436 436 ... ... @@ -449,16 +449,18 @@ 449 449 * **c: define the position for valid value. ** 450 450 ))) 451 451 452 -Examples: 466 +**Examples:** 453 453 454 454 * Grab bytes: 455 455 456 456 [[image:1653271581490-837.png||height="313" width="722"]] 457 457 472 + 458 458 * Grab a section. 459 459 460 460 [[image:1653271648378-342.png||height="326" width="720"]] 461 461 477 + 462 462 * Grab different sections. 463 463 464 464 [[image:1653271657255-576.png||height="305" width="730"]] ... ... @@ -501,6 +501,7 @@ 501 501 502 502 [[image:1653271763403-806.png]] 503 503 520 + 504 504 === 3.3.4 Compose the uplink payload === 505 505 506 506 ((( ... ... @@ -508,7 +508,7 @@ 508 508 ))) 509 509 510 510 ((( 511 -(% style="color:# 4f81bd" %)**Examples: AT+DATAUP=0**528 +(% style="color:#037691" %)**Examples: AT+DATAUP=0** 512 512 ))) 513 513 514 514 ((( ... ... @@ -520,7 +520,7 @@ 520 520 ))) 521 521 522 522 ((( 523 -(% style="color:#4f81bd" %)Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx 540 +(% style="color:#4f81bd" %)**Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx** 524 524 ))) 525 525 526 526 ((( ... ... @@ -529,8 +529,12 @@ 529 529 530 530 [[image:1653272787040-634.png||height="515" width="719"]] 531 531 549 + 550 + 532 532 ((( 533 -(% style="color:#4f81bd" %)**Examples: AT+DATAUP=1** 552 +(% style="color:#037691" %)**Examples: AT+DATAUP=1** 553 + 554 + 534 534 ))) 535 535 536 536 ((( ... ... @@ -542,7 +542,7 @@ 542 542 ))) 543 543 544 544 ((( 545 -(% style="color:#4f81bd" %)Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA 566 +(% style="color:#4f81bd" %)**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA** 546 546 ))) 547 547 548 548 1. ((( ... ... @@ -565,6 +565,7 @@ 565 565 566 566 So totally there will be 3 uplinks for this sampling, each uplink includes 6 bytes DATA 567 567 589 + 568 568 DATA1=RETURN1 Valid Value = (% style="background-color:#4f81bd; color:white" %) 20 20 0a 33 90 41 569 569 570 570 DATA2=1^^st^^ ~~ 6^^th^^ byte of Valid value of RETURN10= (% style="background-color:#4f81bd; color:white" %)02 aa 05 81 0a 20 ... ... @@ -571,10 +571,12 @@ 571 571 572 572 DATA3=7^^th^^ ~~ 11^^th^^ bytes of Valid value of RETURN10 =(% style="background-color:#4f81bd; color:white" %) 20 20 20 2d 30 573 573 596 + 574 574 Below are the uplink payloads: 575 575 576 576 [[image:1653272901032-107.png]] 577 577 601 + 578 578 (% style="color:red" %)Notice: the Max bytes is according to the max support bytes in different Frequency Bands for lowest SF. As below: 579 579 580 580 ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink ( so 51 -5 = 46 max valid date) ... ... @@ -585,6 +585,8 @@ 585 585 586 586 ~* For all other bands: max 51 bytes for each uplink ( so 51 -5 = 46 max valid date). 587 587 612 + 613 + 588 588 === 3.3.5 Uplink on demand === 589 589 590 590 ((( ... ... @@ -601,6 +601,8 @@ 601 601 602 602 ((( 603 603 **0xA8 command**: Send a command to RS485-BL and uplink the output from sensors. 630 + 631 + 604 604 ))) 605 605 606 606 === 3.3.6 Uplink on Interrupt === ... ... @@ -609,14 +609,25 @@ 609 609 610 610 [[image:1653273818896-432.png]] 611 611 640 + 641 +((( 612 612 AT+INTMOD=0 Disable Interrupt 643 +))) 613 613 645 +((( 614 614 AT+INTMOD=1 Interrupt trigger by rising or falling edge. 647 +))) 615 615 649 +((( 616 616 AT+INTMOD=2 Interrupt trigger by falling edge. ( Default Value) 651 +))) 617 617 653 +((( 618 618 AT+INTMOD=3 Interrupt trigger by rising edge. 619 619 656 + 657 +))) 658 + 620 620 == 3.4 Uplink Payload == 621 621 622 622 (% border="1" style="background-color:#4f81bd; color:white; width:850px" %) ... ... @@ -641,92 +641,117 @@ 641 641 642 642 Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors. 643 643 683 +((( 684 +{{{function Decoder(bytes, port) {}}} 685 +))) 644 644 645 -function Decoder(bytes, port) { 687 +((( 688 +{{{//Payload Formats of RS485-BL Deceive}}} 689 +))) 646 646 647 -~/~/Payload Formats of RS485-BL Deceive 691 +((( 692 +{{{return {}}} 693 +))) 648 648 649 -return { 695 +((( 696 +{{{ //Battery,units:V}}} 697 +))) 650 650 651 - ~/~/Battery,units:V 699 +((( 700 +{{{ BatV:((bytes[0]<<8 | bytes[1])&0x7fff)/1000,}}} 701 +))) 652 652 653 - BatV:((bytes[0]<<8 | bytes[1])&0x7fff)/1000, 703 +((( 704 +{{{ //GPIO_EXTI }}} 705 +))) 654 654 655 - ~/~/GPIO_EXTI 707 +((( 708 +{{{ EXTI_Trigger:(bytes[0] & 0x80)? "TRUE":"FALSE",}}} 709 +))) 656 656 657 - EXTI_Trigger:(bytes[0] & 0x80)? "TRUE":"FALSE", 711 +((( 712 +{{{ //payload of version}}} 713 +))) 658 658 659 - ~/~/payload of version 715 +((( 716 +{{{ Pay_ver:bytes[2],}}} 717 +))) 660 660 661 - Pay_ver:bytes[2], 719 +((( 720 +{{{ }; }}} 721 +))) 662 662 663 - }; 723 +((( 724 +} 664 664 665 - } 726 + 727 +))) 666 666 667 - 668 - 669 - 670 - 671 - 672 - 729 +((( 673 673 TTN V3 uplink screen shot. 731 +))) 674 674 675 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]733 +[[image:1653274001211-372.png||height="192" width="732"]] 676 676 677 -1. 678 -11. Configure RS485-BL via AT or Downlink 679 679 680 - Usercanconfigure RS485-BL via[[ATCommands >>path:#_Using_the_AT]]orLoRaWANDownlinkCommands736 +== 3.5 Configure RS485-BL via AT or Downlink == 681 681 738 +User can configure RS485-BL via AT Commands or LoRaWAN Downlink Commands 739 + 682 682 There are two kinds of Commands: 683 683 684 -* **Common Commands**: They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands742 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 685 685 686 -* **Sensor Related Commands**: These commands are special designed for RS485-BL. User can see these commands below: 744 +* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL. User can see these commands below: 687 687 688 -1. 689 -11. 690 -111. Common Commands: 746 +=== 3.5.1 Common Commands: === 691 691 692 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[ http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands]]748 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 693 693 694 694 695 -1. 696 -11. 697 -111. Sensor related commands: 751 +=== 3.5.2 Sensor related commands: === 698 698 699 -==== ChooseDeviceType (RS485 or TTL)====753 +==== ==== 700 700 755 +==== **Choose Device Type (RS485 or TTL)** ==== 756 + 701 701 RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect. 702 702 703 -* AT Command 759 +* **AT Command** 704 704 761 +(% class="box infomessage" %) 762 +((( 705 705 **AT+MOD=1** ~/~/ Set to support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins. 764 +))) 706 706 766 +(% class="box infomessage" %) 767 +((( 707 707 **AT+MOD=2** ~/~/ Set to support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins. 769 +))) 708 708 709 709 710 -* Downlink Payload 772 +* **Downlink Payload** 711 711 712 -**0A aa** àsame as AT+MOD=aa774 +**0A aa** ~-~-> same as AT+MOD=aa 713 713 714 714 715 715 716 -==== [[RS485 Debug Command>>path:#downlink_A8]](AT+CFGDEV) ====778 +==== **RS485 Debug Command (AT+CFGDEV)** ==== 717 717 718 718 This command is used to configure the RS485 or TTL sensors; they won’t be used during sampling. 719 719 720 -* AT Command 782 +* **AT Command** 721 721 722 -AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 784 +(% class="box infomessage" %) 785 +((( 786 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 787 +))) 723 723 724 724 m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command. 725 725 726 726 792 +* **Downlink Payload** 727 727 728 -* Downlink Payload 729 - 730 730 Format: A8 MM NN XX XX XX XX YY 731 731 732 732 Where: ... ... @@ -740,15 +740,15 @@ 740 740 741 741 To connect a Modbus Alarm with below commands. 742 742 743 -* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 807 +* The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 744 744 745 -* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 809 +* The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 746 746 747 747 So if user want to use downlink command to control to RS485 Alarm, he can use: 748 748 749 -**A8 01 06 0A 05 00 04 00 01 00**: to activate the RS485 Alarm 813 +(% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm 750 750 751 -**A8 01 06 0A 05 00 04 00 00 00**: to deactivate the RS485 Alarm 815 +(% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm 752 752 753 753 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output. 754 754 ... ... @@ -757,48 +757,60 @@ 757 757 758 758 Check TTL Sensor return: 759 759 760 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]824 +[[image:1654132684752-193.png]] 761 761 762 762 763 763 828 +==== **Set Payload version** ==== 764 764 765 -==== Set Payload version ==== 766 - 767 767 This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. 768 768 769 -* AT Command: 832 +* **AT Command:** 770 770 771 -AT+PAYVER: Set PAYVER field = 1 834 +(% class="box infomessage" %) 835 +((( 836 +**AT+PAYVER: Set PAYVER field = 1** 837 +))) 772 772 773 773 774 -* Downlink Payload: 840 +* **Downlink Payload:** 775 775 776 -0xAE 01 àSet PAYVER field = 0x01842 +**0xAE 01** ~-~-> Set PAYVER field = 0x01 777 777 778 -0xAE 0F àSet PAYVER field = 0x0F844 +**0xAE 0F** ~-~-> Set PAYVER field = 0x0F 779 779 780 780 781 -==== Set RS485 Sampling Commands ==== 782 782 848 +==== **Set RS485 Sampling Commands** ==== 849 + 783 783 AT+COMMANDx, AT+DATACUTx and AT+SEARCHx 784 784 785 -These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>> path:#polling_485]].852 +These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 786 786 787 787 788 -* AT Command: 855 +* **AT Command:** 789 789 790 -AT+COMMANDx: Configure RS485 read command to sensor. 857 +(% class="box infomessage" %) 858 +((( 859 +**AT+COMMANDx: Configure RS485 read command to sensor.** 860 +))) 791 791 792 -AT+DATACUTx: Configure how to handle return from RS485 devices. 862 +(% class="box infomessage" %) 863 +((( 864 +**AT+DATACUTx: Configure how to handle return from RS485 devices.** 865 +))) 793 793 794 -AT+SEARCHx: Configure search command 867 +(% class="box infomessage" %) 868 +((( 869 +**AT+SEARCHx: Configure search command** 870 +))) 795 795 796 796 797 -* Downlink Payload: 873 +* **Downlink Payload:** 798 798 799 -0xAF downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 875 +**0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 800 800 801 -Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 877 +(% style="color:red" %)**Note**(%%): if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 802 802 803 803 Format: AF MM NN LL XX XX XX XX YY 804 804 ... ... @@ -805,23 +805,23 @@ 805 805 Where: 806 806 807 807 * MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 808 -* NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 809 -* LL: The length of AT+COMMAND or AT+DATACUT command 884 +* NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 885 +* LL: The length of AT+COMMAND or AT+DATACUT command 810 810 * XX XX XX XX: AT+COMMAND or AT+DATACUT command 811 -* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command. 887 +* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command. 812 812 813 -Example: 889 +**Example:** 814 814 815 -**AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1 891 +(% style="color:#037691" %)**AF 03 01 06 0A 05 00 04 00 01 00**(%%): Same as AT+COMMAND3=0A 05 00 04 00 01,1 816 816 817 -**AF 03 02 06 10 01 05 06 09 0A 00**: Same as AT+DATACUT3=**16**,**1**,**5+6+9+10** 893 +(% style="color:#037691" %)**AF 03 02 06**(% style="color:orange" %)** 10 **(% style="color:red" %)**01 **(% style="color:green" %)**05 06 09 0A**(% style="color:#037691" %)** 00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**16**(%%),(% style="color:red" %)**1**(%%),(% style="color:green" %)**5+6+9+10** 818 818 819 -**AF 03 02 06 0B 02 05 07 08 0A 00**: Same as AT+DATACUT3=**11**,**2**,**5~~7+8~~10** 895 +(% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10** 820 820 821 821 822 -0xAB downlink command can be used for set AT+SEARCHx 898 +**0xAB** downlink command can be used for set AT+SEARCHx 823 823 824 -Example: **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So 900 +**Example:** **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So 825 825 826 826 * AB aa 01 03 xx xx xx same as AT+SEARCHaa=1,xx xx xx 827 827 * AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands ... ... @@ -829,145 +829,164 @@ 829 829 **AB aa 02 03 xx xx xx 02 yy yy** same as **AT+SEARCHaa=2,xx xx xx+yy yy** 830 830 831 831 832 -==== Fast command to handle MODBUS device ==== 833 833 909 +==== **Fast command to handle MODBUS device** ==== 910 + 834 834 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 835 835 836 836 This command is valid since v1.3 firmware version 837 837 838 838 839 -AT+MBFUN has only two value: 916 +**AT+MBFUN has only two value:** 840 840 841 -* AT+MBFUN=1: Enable Modbus reading. And get response base on the MODBUS return 918 +* **AT+MBFUN=1**: Enable Modbus reading. And get response base on the MODBUS return 842 842 843 843 AT+MBFUN=1, device can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore. 844 844 845 -* AT+MBFUN=0: Disable Modbus fast reading. 922 +* **AT+MBFUN=0**: Disable Modbus fast reading. 846 846 847 -Example: 924 +**Example:** 848 848 849 849 * AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). 850 850 * AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 851 851 * AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 852 852 853 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]930 +[[image:1654133913295-597.png]] 854 854 855 855 856 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]]933 +[[image:1654133954153-643.png]] 857 857 858 858 859 -* Downlink Commands: 936 +* **Downlink Commands:** 860 860 861 -A9 aa - àSame as AT+MBFUN=aa938 +**A9 aa** ~-~-> Same as AT+MBFUN=aa 862 862 863 863 864 -==== RS485 command timeout ==== 865 865 942 +==== **RS485 command timeout** ==== 943 + 866 866 Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action. 867 867 868 868 Default value: 0, range: 0 ~~ 5 seconds 869 869 870 870 871 -* AT Command: 949 +* **AT Command:** 872 872 873 -AT+CMDDLaa=hex(bb cc) 951 +(% class="box infomessage" %) 952 +((( 953 +**AT+CMDDLaa=hex(bb cc)** 954 +))) 874 874 875 -Example: 956 +**Example:** 876 876 877 877 **AT+CMDDL1=1000** to send the open time to 1000ms 878 878 879 879 880 -* Downlink Payload: 961 +* **Downlink Payload:** 881 881 882 882 0x AA aa bb cc 883 883 884 884 Same as: AT+CMDDLaa=hex(bb cc) 885 885 886 - Example: 967 + **Example:** 887 887 888 - 0xAA 01 03 E8 àSame as **AT+CMDDL1=1000 ms**969 + **0xAA 01 03 E8** ~-~-> Same as **AT+CMDDL1=1000 ms** 889 889 890 890 891 -==== [[Uplink>>path:#downlink_A8]] payload mode ==== 892 892 973 +==== **Uplink payload mode** ==== 974 + 893 893 Define to use one uplink or multiple uplinks for the sampling. 894 894 895 -The use of this command please see: [[Compose Uplink payload>> path:#DataUP]]977 +The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 896 896 897 -* AT Command: 979 +* **AT Command:** 898 898 899 -AT+DATAUP=0 981 +(% class="box infomessage" %) 982 +((( 983 +**AT+DATAUP=0** 984 +))) 900 900 901 -AT+DATAUP=1 986 +(% class="box infomessage" %) 987 +((( 988 +**AT+DATAUP=1** 989 +))) 902 902 903 903 904 -* Downlink Payload: 992 +* **Downlink Payload:** 905 905 906 -0xAD 00 àSame as AT+DATAUP=0994 +**0xAD 00** **~-~->** Same as AT+DATAUP=0 907 907 908 -0xAD 01 àSame as AT+DATAUP=1996 +**0xAD 01** **~-~->** Same as AT+DATAUP=1 909 909 910 910 911 -==== Manually trigger an Uplink ==== 912 912 1000 +==== **Manually trigger an Uplink** ==== 1001 + 913 913 Ask device to send an uplink immediately. 914 914 915 -* Downlink Payload: 1004 +* **Downlink Payload:** 916 916 917 -0x08 FF, RS485-BL will immediately send an uplink. 1006 +**0x08 FF**, RS485-BL will immediately send an uplink. 918 918 919 919 920 -==== Clear RS485 Command ==== 921 921 1010 +==== **Clear RS485 Command** ==== 1011 + 922 922 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 923 923 924 924 925 -* AT Command: 1015 +* **AT Command:** 926 926 927 -**AT+CMDEAR=mm,nn** 1017 +(% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 928 928 929 -Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 930 - 931 931 Example screen shot after clear all RS485 commands. 932 932 933 933 934 - 935 935 The uplink screen shot is: 936 936 937 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]1024 +[[image:1654134704555-320.png]] 938 938 939 939 940 -* Downlink Payload: 1027 +* **Downlink Payload:** 941 941 942 -0x09 aa bb same as AT+CMDEAR=aa,bb 1029 +**0x09 aa bb** same as AT+CMDEAR=aa,bb 943 943 944 944 945 -==== Set Serial Communication Parameters ==== 946 946 1033 +==== **Set Serial Communication Parameters** ==== 1034 + 947 947 Set the Rs485 serial communication parameters: 948 948 949 -* AT Command: 1037 +* **AT Command:** 950 950 951 951 Set Baud Rate: 952 952 953 -AT+BAUDR=9600 ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1041 +(% class="box infomessage" %) 1042 +((( 1043 +**AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1044 +))) 954 954 1046 +Set UART Parity 955 955 956 -Set UART parity 1048 +(% class="box infomessage" %) 1049 +((( 1050 +**AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1051 +))) 957 957 958 -AT+PARITY=0 ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 959 - 960 - 961 961 Set STOPBIT 962 962 963 -AT+STOPBIT=0 ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1055 +(% class="box infomessage" %) 1056 +((( 1057 +**AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1058 +))) 964 964 965 965 966 -* Downlink Payload: 1061 +* **Downlink Payload:** 967 967 968 -A7 01 aa bb: Same AT+BAUDR=hex(aa bb)*100 1063 +**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 969 969 970 -Example: 1065 +**Example:** 971 971 972 972 * A7 01 00 60 same as AT+BAUDR=9600 973 973 * A7 01 04 80 same as AT+BAUDR=115200 ... ... @@ -977,108 +977,102 @@ 977 977 A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 978 978 979 979 980 -==== Control output power duration ==== 981 981 1076 +==== **Control output power duration** ==== 1077 + 982 982 User can set the output power duration before each sampling. 983 983 984 -* AT Command: 1080 +* **AT Command:** 985 985 986 -Example: 1082 +**Example:** 987 987 988 -AT+3V3T=1000 ~/~/ 3V3 output power will open 1s before each sampling. 1084 +**AT+3V3T=1000** ~/~/ 3V3 output power will open 1s before each sampling. 989 989 990 -AT+5VT=1000 ~/~/ +5V output power will open 1s before each sampling. 1086 +**AT+5VT=1000** ~/~/ +5V output power will open 1s before each sampling. 991 991 992 992 993 -* LoRaWAN Downlink Command: 1089 +* **LoRaWAN Downlink Command:** 994 994 995 -07 01 aa bb Same as AT+5VT=(aa bb) 1091 +**07 01 aa bb** Same as AT+5VT=(aa bb) 996 996 997 -07 02 aa bb Same as AT+3V3T=(aa bb) 1093 +**07 02 aa bb** Same as AT+3V3T=(aa bb) 998 998 999 999 1096 +== 3.6 Buttons == 1000 1000 1098 +(% border="1" style="background-color:#ffffcc; color:green; width:233px" %) 1099 +|=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature** 1100 +|(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL 1001 1001 1002 -1. 1003 -11. Buttons 1102 +== 3.7 +3V3 Output == 1004 1004 1005 -|**Button**|**Feature** 1006 -|**RST**|Reboot RS485-BL 1007 - 1008 -1. 1009 -11. +3V3 Output 1010 - 1011 1011 RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor. 1012 1012 1013 1013 The +3V3 output will be valid for every sampling. RS485-BL will enable +3V3 output before all sampling and disable the +3V3 after all sampling. 1014 1014 1015 - 1016 1016 The +3V3 output time can be controlled by AT Command. 1017 1017 1018 -**AT+3V3T=1000** 1019 1019 1020 - Meansset+3v3 valid timetohave 1000ms. So, thereal+3v3output will actually have1000ms + sampling time for other sensors.1111 +(% style="color:#037691" %)**AT+3V3T=1000** 1021 1021 1022 1022 1114 +Means set +3v3 valid time to have 1000ms. So, the real +3v3 output will actually have 1000ms + sampling time for other sensors. 1115 + 1023 1023 By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time 1024 1024 1025 1025 1026 -1. 1027 -11. +5V Output 1119 +== 3.8 +5V Output == 1028 1028 1029 1029 RS485-BL has a Controllable +5V output, user can use this output to power external sensor. 1030 1030 1031 1031 The +5V output will be valid for every sampling. RS485-BL will enable +5V output before all sampling and disable the +5v after all sampling. 1032 1032 1033 - 1034 1034 The 5V output time can be controlled by AT Command. 1035 1035 1036 -**AT+5VT=1000** 1037 1037 1038 - Meansset5V valid timetohave 1000ms. So, thereal5Voutput will actually have1000ms + sampling time for other sensors.1128 +(% style="color:#037691" %)**AT+5VT=1000** 1039 1039 1040 1040 1131 +Means set 5V valid time to have 1000ms. So, the real 5V output will actually have 1000ms + sampling time for other sensors. 1132 + 1041 1041 By default, the AT+5VT=0. If the external sensor which require 5v and require more time to get stable state, user can use this command to increase the power ON duration for this sensor. 1042 1042 1043 1043 1136 +== 3.9 LEDs == 1044 1044 1138 +(% border="1" style="background-color:#ffffcc; color:green; width:332px" %) 1139 +|=**LEDs**|=(% style="width: 274px;" %)**Feature** 1140 +|**LED1**|(% style="width:274px" %)Blink when device transmit a packet. 1045 1045 1046 -1. 1047 -11. LEDs 1142 +== 3.10 Switch Jumper == 1048 1048 1049 -|**LEDs**|**Feature** 1050 -|**LED1**|Blink when device transmit a packet. 1051 - 1052 -1. 1053 -11. Switch Jumper 1054 - 1055 -|**Switch Jumper**|**Feature** 1056 -|**SW1**|((( 1144 +(% border="1" style="background-color:#ffffcc; color:green; width:515px" %) 1145 +|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature** 1146 +|(% style="width:124px" %)**SW1**|(% style="width:388px" %)((( 1057 1057 ISP position: Upgrade firmware via UART 1058 1058 1059 1059 Flash position: Configure device, check running status. 1060 1060 ))) 1061 -|**SW2**|((( 1151 +|(% style="width:124px" %)**SW2**|(% style="width:388px" %)((( 1062 1062 5V position: set to compatible with 5v I/O. 1063 1063 1064 1064 3.3v position: set to compatible with 3.3v I/O., 1065 1065 ))) 1066 1066 1067 -+3.3V: is always ON 1157 +**+3.3V**: is always ON 1068 1068 1069 -+5V: Only open before every sampling. The time is by default, it is AT+5VT=0. Max open time. 5000 ms. 1159 +**+5V**: Only open before every sampling. The time is by default, it is AT+5VT=0. Max open time. 5000 ms. 1070 1070 1071 -1. Case Study 1072 1072 1073 - Usercancheck this URL for some casestudies.1162 += 4. Case Study = 1074 1074 1075 - [[http:~~/~~/wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS>>url:http://wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS]]1164 +User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] 1076 1076 1077 1077 1078 1078 1168 += 5. Use AT Command = 1079 1079 1080 -1. Use AT Command 1081 -11. Access AT Command 1170 +== 5.1 Access AT Command == 1082 1082 1083 1083 RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 1084 1084
- 1653274001211-372.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +91.4 KB - Content
- 1654132684752-193.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.8 KB - Content
- 1654133913295-597.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +116.2 KB - Content
- 1654133954153-643.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +91.2 KB - Content
- 1654134704555-320.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +91.4 KB - Content