Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -565,21 +565,18 @@ 565 565 566 566 So totally there will be 3 uplinks for this sampling, each uplink includes 6 bytes DATA 567 567 568 -DATA1=RETURN1 Valid Value = ~(% style="background-color:#4f81bd;color:white" %)(%style="display:none" %) (%%)20 20 0a 33 90 41568 +DATA1=RETURN1 Valid Value = (% style="background-color:#4f81bd; color:white" %) 20 20 0a 33 90 41 569 569 570 -DATA2=1^^st^^ ~~ 6^^th^^ byte of Valid value of RETURN10= ~(% style="background-color:#4f81bd;color:white" %)(% style="display:none" %) (%%)02 aa 05 81 0a 20570 +DATA2=1^^st^^ ~~ 6^^th^^ byte of Valid value of RETURN10= (% style="background-color:#4f81bd; color:white" %)02 aa 05 81 0a 20 571 571 572 -DATA3=7^^th^^ ~~ 11^^th^^ bytes of Valid value of RETURN10 = ~(% style="background-color:#4f81bd;color:white" %)(% style="display:none" %) (%%)20 20 20 2d 30572 +DATA3=7^^th^^ ~~ 11^^th^^ bytes of Valid value of RETURN10 =(% style="background-color:#4f81bd; color:white" %) 20 20 20 2d 30 573 573 574 - 575 - 576 576 Below are the uplink payloads: 577 577 578 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image021.png]]576 +[[image:1653272901032-107.png]] 579 579 578 +(% style="color:red" %)Notice: the Max bytes is according to the max support bytes in different Frequency Bands for lowest SF. As below: 580 580 581 -Notice: the Max bytes is according to the max support bytes in different Frequency Bands for lowest SF. As below: 582 - 583 583 ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink ( so 51 -5 = 46 max valid date) 584 584 585 585 * For AU915/AS923 bands, if UplinkDwell time=1, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date). ... ... @@ -588,28 +588,30 @@ 588 588 589 589 ~* For all other bands: max 51 bytes for each uplink ( so 51 -5 = 46 max valid date). 590 590 588 +=== 3.3.5 Uplink on demand === 591 591 592 - 593 -1. 594 -11. 595 -111. Uplink on demand 596 - 590 +((( 597 597 Except uplink periodically, RS485-BL is able to uplink on demand. The server sends downlink command to RS485-BL and RS485 will uplink data base on the command. 592 +))) 598 598 594 +((( 599 599 Downlink control command: 596 +))) 600 600 601 -[[0x08 command>>path:#downlink_08]]: Poll an uplink with current command set in RS485-BL. 598 +((( 599 +**0x08 command**: Poll an uplink with current command set in RS485-BL. 600 +))) 602 602 603 -[[0xA8 command>>path:#downlink_A8]]: Send a command to RS485-BL and uplink the output from sensors. 602 +((( 603 +**0xA8 command**: Send a command to RS485-BL and uplink the output from sensors. 604 +))) 604 604 606 +=== 3.3.6 Uplink on Interrupt === 605 605 608 +Put the interrupt sensor between 3.3v_out and GPIO ext. 606 606 607 -1. 608 -11. 609 -111. Uplink on Interrupt 610 +[[image:1653273818896-432.png]] 610 610 611 -Put the interrupt sensor between 3.3v_out and GPIO ext.[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]] 612 - 613 613 AT+INTMOD=0 Disable Interrupt 614 614 615 615 AT+INTMOD=1 Interrupt trigger by rising or falling edge. ... ... @@ -618,10 +618,8 @@ 618 618 619 619 AT+INTMOD=3 Interrupt trigger by rising edge. 620 620 620 +== 3.4 Uplink Payload == 621 621 622 -1. 623 -11. Uplink Payload 624 - 625 625 |**Size(bytes)**|**2**|**1**|**Length depends on the return from the commands** 626 626 |Value|((( 627 627 Battery(mV)
- 1653273818896-432.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.6 KB - Content