Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -60,7 +60,7 @@ 60 60 * Power Consumption (exclude RS485 device): 61 61 ** Idle: 6uA@3.3v 62 62 63 -* 63 +* 64 64 ** 20dB Transmit: 130mA@3.3v 65 65 66 66 **Interface for Model:** ... ... @@ -463,74 +463,113 @@ 463 463 464 464 [[image:1653271657255-576.png||height="305" width="730"]] 465 465 466 +((( 466 466 (% style="color:red" %)**Note:** 468 +))) 467 467 470 +((( 468 468 AT+SEARCHx and AT+DATACUTx can be used together, if both commands are set, RS485-BL will first process AT+SEARCHx on the return string and get a temporary string, and then process AT+DATACUTx on this temporary string to get the final payload. In this case, AT+DATACUTx need to set to format AT+DATACUTx=0,xx,xx where the return bytes set to 0. 472 +))) 469 469 474 +((( 470 470 **Example:** 476 +))) 471 471 478 +((( 472 472 (% style="color:red" %)AT+COMMAND1=11 01 1E D0,0 480 +))) 473 473 482 +((( 474 474 (% style="color:red" %)AT+SEARCH1=1,1E 56 34 484 +))) 475 475 486 +((( 476 476 (% style="color:red" %)AT+DATACUT1=0,2,1~~5 488 +))) 477 477 490 +((( 478 478 (% style="color:red" %)Return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49 492 +))) 479 479 494 +((( 480 480 (% style="color:red" %)String after SEARCH command: 2e 30 58 5f 36 41 30 31 00 49 496 +))) 481 481 498 +((( 482 482 (% style="color:red" %)Valid payload after DataCUT command: 2e 30 58 5f 36 500 +))) 483 483 484 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image018.png]]502 +[[image:1653271763403-806.png]] 485 485 504 +=== 3.3.4 Compose the uplink payload === 486 486 487 - 488 - 489 -1. 490 -11. 491 -111. Compose the uplink payload 492 - 506 +((( 493 493 Through AT+COMMANDx and AT+DATACUTx we got valid value from each RS485 commands, Assume these valid value are RETURN1, RETURN2, .., to RETURNx. The next step is how to compose the LoRa Uplink Payload by these RETURNs. The command is **AT+DATAUP.** 508 +))) 494 494 510 +((( 511 +(% style="color:#4f81bd" %)**Examples: AT+DATAUP=0** 512 +))) 495 495 496 -**Examples: AT+DATAUP=0** 514 +((( 515 +Compose the uplink payload with value returns in sequence and send with (% style="color:red" %)**A SIGNLE UPLINK**. 516 +))) 497 497 498 -Compose the uplink payload with value returns in sequence and send with **A SIGNLE UPLINK**. 499 - 518 +((( 500 500 Final Payload is 520 +))) 501 501 502 -Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx 522 +((( 523 +(% style="color:#4f81bd" %)Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx 524 +))) 503 503 526 +((( 504 504 Where PAYVER is defined by AT+PAYVER, below is an example screen shot. 528 +))) 505 505 506 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image019.png]]530 +[[image:1653272787040-634.png||height="515" width="719"]] 507 507 532 +((( 533 +(% style="color:#4f81bd" %)**Examples: AT+DATAUP=1** 534 +))) 508 508 536 +((( 537 +Compose the uplink payload with value returns in sequence and send with (% style="color:red" %)**Multiply UPLINKs**. 538 +))) 509 509 510 -**Examples: AT+DATAUP=1** 511 - 512 -Compose the uplink payload with value returns in sequence and send with **Multiply UPLINKs**. 513 - 540 +((( 514 514 Final Payload is 542 +))) 515 515 516 -Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA 544 +((( 545 +(% style="color:#4f81bd" %)Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA 546 +))) 517 517 518 -1. Battery Info (2 bytes): Battery voltage 519 -1. PAYVER (1 byte): Defined by AT+PAYVER 520 -1. PAYLOAD COUNT (1 byte): Total how many uplinks of this sampling. 521 -1. PAYLOAD# (1 byte): Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT) 522 -1. DATA: Valid value: max 6 bytes(US915 version here, [[Notice*!>>path:#max_byte]]) for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 6 bytes 548 +1. ((( 549 +Battery Info (2 bytes): Battery voltage 550 +))) 551 +1. ((( 552 +PAYVER (1 byte): Defined by AT+PAYVER 553 +))) 554 +1. ((( 555 +PAYLOAD COUNT (1 byte): Total how many uplinks of this sampling. 556 +))) 557 +1. ((( 558 +PAYLOAD# (1 byte): Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT) 559 +))) 560 +1. ((( 561 +DATA: Valid value: max 6 bytes(US915 version here, Notice*!) for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 6 bytes 562 +))) 523 523 524 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image020.png]]564 +[[image:1653272817147-600.png||height="437" width="717"]] 525 525 526 - 527 527 So totally there will be 3 uplinks for this sampling, each uplink includes 6 bytes DATA 528 528 529 -DATA1=RETURN1 Valid Value = 20 20 0a 33 90 41 568 +DATA1=RETURN1 Valid Value = ~(% style="background-color:#4f81bd;color:white" %)(% style="display:none" %) (%%)20 20 0a 33 90 41 530 530 531 -DATA2=1^^st^^ ~~ 6^^th^^ byte of Valid value of RETURN10= 02 aa 05 81 0a 20 570 +DATA2=1^^st^^ ~~ 6^^th^^ byte of Valid value of RETURN10= ~(% style="background-color:#4f81bd;color:white" %)(% style="display:none" %) (%%)02 aa 05 81 0a 20 532 532 533 -DATA3=7^^th^^ ~~ 11^^th^^ bytes of Valid value of RETURN10 = 20 20 20 2d 30 572 +DATA3=7^^th^^ ~~ 11^^th^^ bytes of Valid value of RETURN10 =~(% style="background-color:#4f81bd;color:white" %)(% style="display:none" %) (%%) 20 20 20 2d 30 534 534 535 535 536 536 ... ... @@ -551,8 +551,8 @@ 551 551 552 552 553 553 554 -1. 555 -11. 593 +1. 594 +11. 556 556 111. Uplink on demand 557 557 558 558 Except uplink periodically, RS485-BL is able to uplink on demand. The server sends downlink command to RS485-BL and RS485 will uplink data base on the command. ... ... @@ -565,8 +565,8 @@ 565 565 566 566 567 567 568 -1. 569 -11. 607 +1. 608 +11. 570 570 111. Uplink on Interrupt 571 571 572 572 Put the interrupt sensor between 3.3v_out and GPIO ext.[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]] ... ... @@ -580,7 +580,7 @@ 580 580 AT+INTMOD=3 Interrupt trigger by rising edge. 581 581 582 582 583 -1. 622 +1. 584 584 11. Uplink Payload 585 585 586 586 |**Size(bytes)**|**2**|**1**|**Length depends on the return from the commands** ... ... @@ -642,15 +642,15 @@ 642 642 643 643 * **Sensor Related Commands**: These commands are special designed for RS485-BL. User can see these commands below: 644 644 645 -1. 646 -11. 684 +1. 685 +11. 647 647 111. Common Commands: 648 648 649 649 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands]] 650 650 651 651 652 -1. 653 -11. 691 +1. 692 +11. 654 654 111. Sensor related commands: 655 655 656 656 ==== Choose Device Type (RS485 or TTL) ==== ... ... @@ -956,13 +956,13 @@ 956 956 957 957 958 958 959 -1. 998 +1. 960 960 11. Buttons 961 961 962 962 |**Button**|**Feature** 963 963 |**RST**|Reboot RS485-BL 964 964 965 -1. 1004 +1. 966 966 11. +3V3 Output 967 967 968 968 RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor. ... ... @@ -980,7 +980,7 @@ 980 980 By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time 981 981 982 982 983 -1. 1022 +1. 984 984 11. +5V Output 985 985 986 986 RS485-BL has a Controllable +5V output, user can use this output to power external sensor. ... ... @@ -1000,13 +1000,13 @@ 1000 1000 1001 1001 1002 1002 1003 -1. 1042 +1. 1004 1004 11. LEDs 1005 1005 1006 1006 |**LEDs**|**Feature** 1007 1007 |**LED1**|Blink when device transmit a packet. 1008 1008 1009 -1. 1048 +1. 1010 1010 11. Switch Jumper 1011 1011 1012 1012 |**Switch Jumper**|**Feature** ... ... @@ -1052,7 +1052,7 @@ 1052 1052 1053 1053 1054 1054 1055 -1. 1094 +1. 1056 1056 11. Common AT Command Sequence 1057 1057 111. Multi-channel ABP mode (Use with SX1301/LG308) 1058 1058 ... ... @@ -1071,8 +1071,8 @@ 1071 1071 1072 1072 ATZ 1073 1073 1074 -1. 1075 -11. 1113 +1. 1114 +11. 1076 1076 111. Single-channel ABP mode (Use with LG01/LG02) 1077 1077 1078 1078 AT+FDR Reset Parameters to Factory Default, Keys Reserve ... ... @@ -1147,7 +1147,7 @@ 1147 1147 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] 1148 1148 1149 1149 1150 -1. 1189 +1. 1151 1151 11. How to change the LoRa Frequency Bands/Region? 1152 1152 1153 1153 User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download. ... ... @@ -1154,7 +1154,7 @@ 1154 1154 1155 1155 1156 1156 1157 -1. 1196 +1. 1158 1158 11. How many RS485-Slave can RS485-BL connects? 1159 1159 1160 1160 The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]]. ... ... @@ -1171,7 +1171,7 @@ 1171 1171 1172 1172 1173 1173 1174 -1. 1213 +1. 1175 1175 11. Why I can’t join TTN V3 in US915 /AU915 bands? 1176 1176 1177 1177 It might about the channels mapping. Please see for detail.
- 1653272787040-634.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +294.0 KB - Content
- 1653272817147-600.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +143.3 KB - Content