- Title
-
... ... @@ -1,1 +1,1 @@ 1 -WQS-LB _Dragino_LoRaWAN_Water_Quality_Sensor_User_Manual1 +WQS-LB -- Dragino LoRaWAN Water Quality Sensor User Manual - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. karry1 +XWiki.Xiaoling - Content
-
... ... @@ -720,7 +720,7 @@ 720 720 * Power supply: DC7~~30V 721 721 * Power consumption: ≤0.5W 722 722 * Communication interface: RS485; standard MODBUS-RTU protocol; communication baud rate: default 9600 723 -* Conductivity measurement range: K=1: 1~~2000μs/cm; resolution: 1μs/cm K=10: 10~~20000μs/cm; resolution: 10μ 723 +* Conductivity measurement range: K=1: 1~~2000μs/cm; resolution: 1μs/cm K=10: 10~~20000μs/cm; resolution: 10μs/cm 724 724 * Conductivity measurement error: ±1%FS 725 725 * Equipment working conditions: Ambient temperature: 0-60℃ 726 726 * Waterproof grade: IP68 ... ... @@ -800,7 +800,7 @@ 800 800 (% style="color:#4472c4" %)**"AT+CALEC=10" downlink:0xFD 10** 801 801 802 802 803 -== 4.3 ORP Sensor ~-~-==803 +== 4.3 ORP Sensor == 804 804 805 805 806 806 ((( ... ... @@ -900,7 +900,7 @@ 900 900 (% style="color:#4472c4" %)**"AT+CALORP=256" downlink:0xFD 01 00** 901 901 902 902 903 -== 4.4 dissolvedoxygen Sensor ==903 +== 4.4 Dissolved Oxygen Sensor == 904 904 905 905 906 906 ((( ... ... @@ -967,7 +967,7 @@ 967 967 * Do not arbitrarily change the components or wires that have been welded at the factory when using the product. 968 968 * The sensor is a precision device. When using it, please do not disassemble it by yourself or contact the sensor surface with sharp objects or corrosive liquids to avoid damaging the product. 969 969 970 -== 4.5 turbidity Sensor ==970 +== 4.5 Turbidity Sensor == 971 971 972 972 973 973 ((( ... ... @@ -1019,6 +1019,7 @@ 1019 1019 1020 1020 === 4.5.5 Calibration === 1021 1021 1022 + 1022 1022 For turbidity calibration, you only need to prepare a solution. You can choose 0NTU, 200NTU, 400NTU, 600NTU, 800NTU, 1000NTU, and then enter the corresponding calibration command. 1023 1023 1024 1024 (% style="color:#4472c4" %)**"AT+CALNTU=0" downlink:0xFE 00 **(%%)0NTU turbidity solution ... ... @@ -1034,10 +1034,9 @@ 1034 1034 (% style="color:#4472c4" %)**"AT+CALNTU=10" downlink:0xFE 0A **(%%)1000NTU turbidity solution 1035 1035 1036 1036 1037 - 1038 - 1039 1039 === 4.5.6 Precautions === 1040 1040 1040 + 1041 1041 * To ensure that the electrode measures correctly on the pipeline, avoid bubbles between the measuring cells that may cause data inaccuracy. 1042 1042 * Please check whether the packaging is intact and whether the product model is consistent with the selected model. 1043 1043 * Do not connect the wires with power on. After the wiring is completed and checked, power can be turned on. ... ... @@ -1073,8 +1073,8 @@ 1073 1073 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:500px" %) 1074 1074 |=(% style="width: 300px;background-color:#4F81BD;color:white" %)**Sensor Model**|=(% style="width: 200px;background-color:#4F81BD;color:white" %)**Part Number** 1075 1075 |(% style="width:462px" %)PH Sensor|(% style="width:120px" %)DR-PH01 1076 -|(% style="width:462px" %)EC K1 Sensor|(% style="width:120px" %)DR-ECK1 1077 -|(% style="width:462px" %)EC K10 Sensor|(% style="width:120px" %)DR-ECK10 1076 +|(% style="width:462px" %)EC K1 Sensor|(% style="width:120px" %)DR-ECK1.0 1077 +|(% style="width:462px" %)EC K10 Sensor|(% style="width:120px" %)DR-ECK10.0 1078 1078 |(% style="width:462px" %)ORP Sensor|(% style="width:120px" %)DR-ORP1 1079 1079 |(% style="width:462px" %)Dissolved Oxygen Sensor|(% style="width:120px" %)DR-DO1 1080 1080 |(% style="width:462px" %)Turbidity Sensor|(% style="width:120px" %)DR-TS1