Changes for page WQS-NB/NS -- NB-IoT Water Quality Sensor Transmitter User Manual
Last modified by kai on 2025/08/06 10:05
From version 161.1
edited by Karry Zhuang
on 2024/07/26 16:33
on 2024/07/26 16:33
Change comment:
There is no comment for this version
To version 162.1
edited by Karry Zhuang
on 2024/07/26 16:36
on 2024/07/26 16:36
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -85,7 +85,7 @@ 85 85 * Support multiply RS485 devices by flexible rules 86 86 * Support Modbus protocol 87 87 * Support Interrupt uplink 88 -* Supports connecting a UART sensors with 3.3V or 5V 88 +* Supports connecting a UART sensors with 3.3V or 5V or 12v 89 89 * Support Bluetooth v5.1 and LoRaWAN remote configure 90 90 * Support wireless OTA update firmware 91 91 * AT Commands to change parameters ... ... @@ -92,7 +92,6 @@ 92 92 * Uplink on periodically 93 93 * Downlink to change configure 94 94 * 8500mAh Li/SOCl2 Battery (RS485-LB) 95 -* Solar panel + 3000mAh Li-on battery (RS485-LS) 96 96 97 97 == 1.4 Applications == 98 98 ... ... @@ -535,76 +535,13 @@ 535 535 * Example 1: Downlink Payload: 070000 **~-~-->** AT+5VT=0 536 536 * Example 2: Downlink Payload: 0701F4 **~-~-->** AT+5VT=500 537 537 538 -== == 539 539 540 -= 4. Powerconsumptionand battery=538 += 4. Water Qualit Sensors = 541 541 542 -== 4.1 TotalPowerConsumption==540 +== 4.1 PH Sensor == 543 543 544 544 545 -Dragino Weather Station serial products include the main process unit ( WQS-L B) and various sensors. The total power consumption equal total power of all above units. The power consumption for main process unit WQS-LB is 18ma @ 12v. and the power consumption of each sensor can be found on the Sensors chapter. 546 - 547 - 548 -== 4.2 Reduce power consumption == 549 - 550 - 551 -The main process unit WQS-LB is set to LoRaWAN Class C by default. If user want to reduce the power consumption of this unit, user can set it to run in Class A. In Class A mode, WQS-LB will not be to get real-time downlink command from IoT Server. 552 - 553 - 554 -== 4.3 Battery == 555 - 556 - 557 557 ((( 558 -All sensors are only power by external power source. If external power source is off. All sensor won't work. 559 -))) 560 - 561 -((( 562 -Main Process Unit WQS-LB is powered by both external power source and internal 1000mAh rechargeable battery. If external power source is off, WQS-LB still runs and can send periodically uplinks, but the sensors value will become invalid. External power source can recharge the 1000mAh rechargeable battery. 563 -))) 564 - 565 - 566 -= 5. Main Process Unit WQS-LB = 567 - 568 -== 5.1 Features == 569 - 570 - 571 -* Wall Attachable. 572 -* LoRaWAN v1.0.3 Class A protocol. 573 -* RS485 / Modbus protocol 574 -* Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915 575 -* AT Commands to change parameters 576 -* Remote configure parameters via LoRaWAN Downlink 577 -* Firmware upgradable via program port 578 -* Powered by external 12v battery 579 -* Back up rechargeable 1000mAh battery 580 -* IP Rating: IP65 581 -* Support default sensors or 3rd party RS485 sensors 582 - 583 -== 5.2 Power Consumption == 584 - 585 - 586 -WQS-LB (without external sensor): Idle: 4mA, Transmit: max 40mA 587 - 588 - 589 -== 5.3 Storage & Operation Temperature == 590 - 591 - 592 --20°C to +60°C 593 - 594 - 595 -== 5.4 Pin Mapping == 596 - 597 - 598 -[[image:image-20240715175759-2.png]] 599 - 600 - 601 - 602 -= 6. Water Qualit Sensors = 603 - 604 -== 6.1 PH Sensor == 605 - 606 - 607 -((( 608 608 PH01 is a device for measuring the pH value (hydrogen ion concentration index, acidity and alkalinity) of a solution. 609 609 610 610 It adopts an integrated design, is lighter and simpler in structure, and is more convenient to use. The waterproof grade is IP68. ... ... @@ -615,7 +615,7 @@ 615 615 ))) 616 616 617 617 618 -=== 6.1.1 Feature ===554 +=== 4.1.1 Feature === 619 619 620 620 621 621 * pH measurement range 0~~14pH, resolution 0.01pH. ... ... @@ -623,7 +623,7 @@ 623 623 * The reference adopts a double salt bridge design, which has stronger anti-pollution ability and waterproof grade IP68. 624 624 * The equipment adopts a wide voltage power supply DC 7~~30V. 625 625 626 -=== 6.1.2 Specification ===562 +=== 4.1.2 Specification === 627 627 628 628 629 629 * Power supply: DC7~~30V ... ... @@ -636,13 +636,13 @@ 636 636 * Waterproof grade: IP68 637 637 * Pressure resistance: 0.6MPa 638 638 639 -=== 6.1.3 Dimension ===575 +=== 4.1.3 Dimension === 640 640 641 641 642 642 [[image:image-20240715181651-3.png||height="223" width="562"]] 643 643 644 644 645 -=== 6.1.4 Installation Notice ===581 +=== 4.1.4 Installation Notice === 646 646 647 647 648 648 ((( ... ... @@ -687,7 +687,7 @@ 687 687 First rinse the electrode with distilled water, then rinse it with the water sample, then immerse the electrode in the sample, carefully shake the test cup or stir it to accelerate the electrode balance, let it stand, and record the pH value when the reading is stable. 688 688 689 689 690 -=== 6.1.5 Maintenance ===626 +=== 4.1.5 Maintenance === 691 691 692 692 693 693 * The equipment itself generally does not require daily maintenance. When an obvious fault occurs, please do not open it and repair it yourself. Contact us as soon as possible! ... ... @@ -702,7 +702,7 @@ 702 702 The equipment should be calibrated before each use. For long-term use, it is recommended to calibrate once every 3 months. The calibration frequency should be adjusted appropriately according to different application conditions (degree of dirt in the application, deposition of chemical substances, etc.). After aging, the electrodes should be replaced in time. 703 703 ))) 704 704 705 -=== 6.1.6 Calibration ===641 +=== 4.1.6 Calibration === 706 706 707 707 708 708 This device uses three-point calibration, and three known PH standard solutions need to be prepared. ... ... @@ -720,7 +720,7 @@ 720 720 721 721 722 722 723 -== 6.2 EC Sensor ==659 +== 4.2 EC Sensor == 724 724 725 725 726 726 EC K1/K10 is a device for measuring the conductivity of solutions. EC K1/K10 adopts an integrated design, which is lighter and simpler in structure and more convenient to use. ... ... @@ -731,7 +731,7 @@ 731 731 732 732 ))) 733 733 734 -=== 6.2.1 Feature ===670 +=== 4.2.1 Feature === 735 735 736 736 737 737 * Conductivity measurement range is 0-2000us/cm; 10~~20000us/cm. ... ... @@ -742,7 +742,7 @@ 742 742 * ModBus communication address can be set and baud rate can be modified. 743 743 * The device adopts wide voltage power supply, DC 7~~30V is available. 744 744 745 -=== 6.2.2 Specification ===681 +=== 4.2.2 Specification === 746 746 747 747 748 748 * Power supply: DC7~~30V ... ... @@ -754,13 +754,13 @@ 754 754 * Waterproof grade: IP68 755 755 * Pressure resistance: 0.6MPa 756 756 757 -=== 6.2.3 Dimension ===693 +=== 4.2.3 Dimension === 758 758 759 759 760 760 [[image:image-20240715181651-3.png||height="223" width="562"]] 761 761 762 762 763 -=== 6.2.4 Installation Notice ===699 +=== 4.2.4 Installation Notice === 764 764 765 765 766 766 Selection of matching electrode constant ... ... @@ -804,7 +804,7 @@ 804 804 [[image:image-20240716105318-5.png||height="330" width="594"]] 805 805 806 806 807 -=== 6.2.5 Maintenance ===743 +=== 4.2.5 Maintenance === 808 808 809 809 810 810 * The equipment itself generally does not require daily maintenance. When an obvious fault occurs, please do not open it and repair it yourself, and contact us as soon as possible. ... ... @@ -812,7 +812,7 @@ 812 812 * Cleaning of conductivity electrodes: Organic stains on the electrode can be cleaned with warm water containing detergent, or with alcohol. Calcium and magnesium precipitates are best cleaned with 10% citric acid. The electrode plate or pole can only be cleaned by chemical methods or by shaking in water. Wiping the electrode plate will damage the coating (platinum black) on the electrode surface. 813 813 * The equipment should be calibrated before each use. It is recommended to calibrate it every 3 months for long-term use. The calibration frequency should be adjusted appropriately according to different application conditions (degree of dirt in the application, deposition of chemical substances, etc.). 814 814 815 -=== 6.2.6 Calibration ===751 +=== 4.2.6 Calibration === 816 816 817 817 818 818 This device uses one-point calibration, and you need to prepare a known E standard solution. When the mileage K=1, 1~~2000 uses 1413uS/cm standard solution, and when the mileage K=10, 10~~20000 uses 12.88mS/cm standard solution. ... ... @@ -828,7 +828,7 @@ 828 828 (% style="color:#4472c4" %)**"AT+CALEC=10" downlink:0xFD 10** 829 829 830 830 831 -== 6.3 ORP Sensor ~-~- ==767 +== 4.3 ORP Sensor ~-~- == 832 832 833 833 834 834 ((( ... ... @@ -838,7 +838,7 @@ 838 838 ))) 839 839 840 840 841 -=== 6.3.1 Feature ===777 +=== 4.3.1 Feature === 842 842 843 843 844 844 * ORP measurement range -1999~~1999mV, resolution 1mV. ... ... @@ -848,7 +848,7 @@ 848 848 * ModBus communication address can be set and baud rate can be modified. 849 849 * The equipment adopts wide voltage power supply, DC 7~~30V 850 850 851 -=== 6.3.2 Specification ===787 +=== 4.3.2 Specification === 852 852 853 853 854 854 * Measuring range: -1999~~1999mV ... ... @@ -860,13 +860,13 @@ 860 860 * Waterproof grade: IP68 861 861 * Pressure resistance: 0.6MP 862 862 863 -=== 6.3.3 Dimension ===799 +=== 4.3.3 Dimension === 864 864 865 865 866 866 867 867 [[image:image-20240715181651-3.png||height="223" width="562"]] 868 868 869 -=== 6.3.4 Installation Notice ===805 +=== 4.3.4 Installation Notice === 870 870 871 871 872 872 ((( ... ... @@ -900,7 +900,7 @@ 900 900 901 901 [[image:image-20240715182122-6.png||height="291" width="408"]] 902 902 903 -=== 6.3.5 Maintenance ===839 +=== 4.3.5 Maintenance === 904 904 905 905 906 906 (1) The equipment itself generally does not require daily maintenance. When an obvious fault occurs, please do not open it and repair it yourself, and contact us as soon as possible. ... ... @@ -914,7 +914,7 @@ 914 914 (9) The equipment should be calibrated before each use. It is recommended to calibrate once every 3 months for long-term use. The calibration frequency should be adjusted appropriately according to different application conditions (degree of dirt in the application, deposition of chemical substances, etc.). After aging, the electrodes should be replaced in time. 915 915 916 916 917 -=== 6.3.6 Calibration ===853 +=== 4.3.6 Calibration === 918 918 919 919 920 920 OPR01 uses two-point calibration. You need to prepare two known ORP standard solutions. ... ... @@ -928,7 +928,7 @@ 928 928 (% style="color:#4472c4" %)**"AT+CALORP=256" downlink:0xFD 01 00** 929 929 930 930 931 -== 6.4 dissolved oxygen Sensor ==867 +== 4.4 dissolved oxygen Sensor == 932 932 933 933 934 934 ((( ... ... @@ -946,7 +946,7 @@ 946 946 ))) 947 947 948 948 949 -=== 6.4.1 Feature ===885 +=== 4.4.1 Feature === 950 950 951 951 952 952 * Small size, low power consumption, easy to carry. ... ... @@ -955,7 +955,7 @@ 955 955 * Up to four isolations, can resist complex interference conditions on site, waterproof level IP68. 956 956 * The electrode uses high-quality low-noise cable, which can make the signal output length reach more than 20 meters. 957 957 958 -=== 6.4.2 Specification ===894 +=== 4.4.2 Specification === 959 959 960 960 961 961 * Measuring range: 0-20mg/L, 0-50℃ ... ... @@ -968,12 +968,12 @@ 968 968 * Working environment: temperature 0-60℃; humidity <95%RH 969 969 * Power consumption: ≤0.5W 970 970 971 -=== 6.4.3 Dimension ===907 +=== 4.4.3 Dimension === 972 972 973 973 974 974 [[image:image-20240717105043-2.png||height="232" width="515"]] 975 975 976 -=== 6.4.4 Instructions for use and maintenance ===912 +=== 4.4.4 Instructions for use and maintenance === 977 977 978 978 979 979 * Sampling: Take representative water samples according to the sampling requirements. ... ... @@ -986,7 +986,7 @@ 986 986 If the water conditions are complex and you want accurate data, you need to wipe the sensor probe frequently. 987 987 988 988 989 -=== 6.4.5 Precautions ===925 +=== 4.4.5 Precautions === 990 990 991 991 992 992 * To ensure that the electrode measures correctly on the pipeline, avoid bubbles between the measuring cells that may cause data inaccuracy. ... ... @@ -995,7 +995,7 @@ 995 995 * Do not arbitrarily change the components or wires that have been welded at the factory when using the product. 996 996 * The sensor is a precision device. When using it, please do not disassemble it by yourself or contact the sensor surface with sharp objects or corrosive liquids to avoid damaging the product. 997 997 998 -== 6.5 turbidity Sensor ==934 +== 4.5 turbidity Sensor == 999 999 1000 1000 1001 1001 ((( ... ... @@ -1009,7 +1009,7 @@ 1009 1009 ))) 1010 1010 1011 1011 1012 -=== 6.5.1 Feature ===948 +=== 4.5.1 Feature === 1013 1013 1014 1014 1015 1015 * RS485 Temperature, Humidity, Illuminance, Pressure sensor ... ... @@ -1020,7 +1020,7 @@ 1020 1020 * Up to four isolations can resist complex interference conditions on site, and the waterproof level is IP68. 1021 1021 * The electrode uses high-quality low-noise cable, which can make the signal output length reach more than 20 meters 1022 1022 1023 -=== 6.5.2 Specification ===959 +=== 4.5.2 Specification === 1024 1024 1025 1025 1026 1026 * Measuring range: 0.1~1000.0NTU ... ... @@ -1033,19 +1033,19 @@ 1033 1033 * Working environment: temperature 0~60℃; humidity ≤95%RH 1034 1034 * Power consumption: ≤0.5W 1035 1035 1036 -=== 6.5.3 Dimension ===972 +=== 4.5.3 Dimension === 1037 1037 1038 1038 1039 1039 [[image:image-20240717112849-3.png||height="285" width="582"]] 1040 1040 1041 1041 1042 -=== 6.5.4 Instructions for use and maintenance ===978 +=== 4.5.4 Instructions for use and maintenance === 1043 1043 1044 1044 1045 1045 * It can be directly put into water without adding a protective tube, ensuring the long-term stability, reliability and accuracy of the sensor. 1046 1046 * If the water conditions are complex and you want accurate data, you need to wipe the sensor probe frequently. 1047 1047 1048 -=== 6.5.5 Calibration ===984 +=== 4.5.5 Calibration === 1049 1049 1050 1050 For turbidity calibration, you only need to prepare a solution. You can choose 0NTU, 200NTU, 400NTU, 600NTU, 800NTU, 1000NTU, and then enter the corresponding calibration command. 1051 1051 ... ... @@ -1064,7 +1064,7 @@ 1064 1064 1065 1065 1066 1066 1067 -=== 6.5.6 Precautions ===1003 +=== 4.5.6 Precautions === 1068 1068 1069 1069 * To ensure that the electrode measures correctly on the pipeline, avoid bubbles between the measuring cells that may cause data inaccuracy. 1070 1070 * Please check whether the packaging is intact and whether the product model is consistent with the selected model. ... ... @@ -1073,13 +1073,13 @@ 1073 1073 * The sensor is a precision device. When using it, please do not disassemble it by yourself or contact the sensor surface with sharp objects or corrosive liquids to avoid damaging the product. 1074 1074 * Do not power on while connect the cables. Double check the wiring before power on 1075 1075 1076 -= 7. FAQ =1012 += 5. FAQ = 1077 1077 1078 1078 1079 1079 1080 -= 8. Order Info =1016 += 6. Order Info = 1081 1081 1082 -== 8.1 Main Process Unit ==1018 +== 6.1 Main Process Unit == 1083 1083 1084 1084 1085 1085 Part Number: (% style="color:blue" %)**WQS-LB-XX** ... ... @@ -1095,7 +1095,7 @@ 1095 1095 * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1096 1096 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1097 1097 1098 -== 8.2 Sensors ==1034 +== 6.2 Sensors == 1099 1099 1100 1100 1101 1101 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:500px" %) ... ... @@ -1107,7 +1107,7 @@ 1107 1107 |(% style="width:462px" %)Dissolved Oxygen Sensor|(% style="width:120px" %)DR-DO1 1108 1108 |(% style="width:462px" %)Turbidity Sensor|(% style="width:120px" %)DR-TS1 1109 1109 1110 -= 9. Support =1046 += 7. Support = 1111 1111 1112 1112 1113 1113 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.