Changes for page WQS-NB/NS -- NB-IoT Water Quality Sensor Transmitter User Manual
Last modified by kai on 2025/08/06 10:05
From version 160.1
edited by Karry Zhuang
on 2024/07/26 16:31
on 2024/07/26 16:31
Change comment:
There is no comment for this version
To version 161.1
edited by Karry Zhuang
on 2024/07/26 16:33
on 2024/07/26 16:33
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -168,37 +168,9 @@ 168 168 169 169 = 2. How to use = 170 170 171 -== 2.1 Installation==171 +== 2.1 Example to use for LoRaWAN network == 172 172 173 173 174 -Below is an installation example for the weather station. Field installation example can be found at [[Appendix I: Field Installation Photo.>>||anchor="H11.AppendixI:FieldInstallationPhoto"]] 175 - 176 - 177 -[[image:1656041948552-849.png]] 178 - 179 - 180 - 181 - 182 - 183 -== 2.2 How it works? == 184 - 185 - 186 -((( 187 -Each WQS-LB is shipped with a worldwide unique set of OTAA keys. To use WQS-LB in a LoRaWAN network, user needs to input the OTAA keys in LoRaWAN network server. After finish installation as above. Create WQS-LB in your LoRaWAN server and Power on WQS-LB , it can join the LoRaWAN network and start to transmit sensor data. The default period for each uplink is 20 minutes. 188 -))) 189 - 190 -((( 191 -Open WQS-LB and put the yellow jumper as below position to power on WQS-LB. 192 -))) 193 - 194 -[[image:image-20240715164447-1.png]] 195 - 196 - 197 -(% style="color:red" %)**Notice:**(%%) WQS-LB will auto scan available water quality sensors when power on or reboot. 198 - 199 -== 2.3 Example to use for LoRaWAN network == 200 - 201 - 202 202 This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure. 203 203 204 204 [[image:1656042612899-422.png]] ... ... @@ -241,7 +241,7 @@ 241 241 [[image:1656042745346-283.png]] 242 242 243 243 244 -== 2. 4Uplink Payload ==216 +== 2.2 Uplink Payload == 245 245 246 246 247 247 Uplink payloads include two types: Valid Sensor Value and other status / control command. ... ... @@ -326,7 +326,7 @@ 326 326 ))) 327 327 328 328 329 -=== 2. 4.2 Uplink FPORT~=2, Real time sensor value ===301 +=== 2.2.2 Uplink FPORT~=2, Real time sensor value === 330 330 331 331 332 332 ... ... @@ -409,7 +409,7 @@ 409 409 410 410 ))) 411 411 412 -=== 2. 4.3 Decoder in TTN V3 ===384 +=== 2.2.3 Decoder in TTN V3 === 413 413 414 414 415 415 ((( ... ... @@ -427,7 +427,7 @@ 427 427 [[image:1656051152438-578.png]] 428 428 429 429 430 -== 2. 5Show data on Application Server ==402 +== 2.3 Show data on Application Server == 431 431 432 432 433 433 (((