Changes for page WQS-NB/NS -- NB-IoT Water Quality Sensor Transmitter User Manual
Last modified by kai on 2025/08/06 10:05
From version 146.1
edited by Karry Zhuang
on 2024/07/17 11:45
on 2024/07/17 11:45
Change comment:
There is no comment for this version
To version 147.1
edited by Karry Zhuang
on 2024/07/17 11:47
on 2024/07/17 11:47
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1118,7 +1118,6 @@ 1118 1118 * Do not arbitrarily change the components or wires that have been welded at the factory when using the product. 1119 1119 * The sensor is a precision device. When using it, please do not disassemble it by yourself or contact the sensor surface with sharp objects or corrosive liquids to avoid damaging the product. 1120 1120 1121 - 1122 1122 == 6.5 turbidity Sensor == 1123 1123 1124 1124 ... ... @@ -1157,7 +1157,6 @@ 1157 1157 * Working environment: temperature 0~60℃; humidity ≤95%RH 1158 1158 * Power consumption: ≤0.5W 1159 1159 1160 - 1161 1161 === 6.5.3 Dimension === 1162 1162 1163 1163 ... ... @@ -1170,22 +1170,21 @@ 1170 1170 * It can be directly put into water without adding a protective tube, ensuring the long-term stability, reliability and accuracy of the sensor. 1171 1171 * If the water conditions are complex and you want accurate data, you need to wipe the sensor probe frequently. 1172 1172 1173 - 1174 1174 === 6.5.5 Calibration === 1175 1175 1176 1176 For turbidity calibration, you only need to prepare a solution. You can choose 0NTU, 200NTU, 400NTU, 600NTU, 800NTU, 1000NTU, and then enter the corresponding calibration command. 1177 1177 1178 -(% style="color:#4472c4" %)**"AT+CALNTU=0" downlink:0xFE 00 1175 +(% style="color:#4472c4" %)**"AT+CALNTU=0" downlink:0xFE 00 **(%%)0NTU turbidity solution 1179 1179 1180 -(% style="color:#4472c4" %)**"AT+CALNTU=2" downlink:0xFE 02 1177 +(% style="color:#4472c4" %)**"AT+CALNTU=2" downlink:0xFE 02 **(%%)200NTU turbidity solution 1181 1181 1182 -(% style="color:#4472c4" %)**"AT+CALNTU=4" downlink:0xFE 04 1179 +(% style="color:#4472c4" %)**"AT+CALNTU=4" downlink:0xFE 04 **(%%)400NTU turbidity solution 1183 1183 1184 -(% style="color:#4472c4" %)**"AT+CALNTU=6" downlink:0xFE 06 1181 +(% style="color:#4472c4" %)**"AT+CALNTU=6" downlink:0xFE 06 **(%%)600NTU turbidity solution 1185 1185 1186 -(% style="color:#4472c4" %)**"AT+CALNTU=8" downlink:0xFE 08 1183 +(% style="color:#4472c4" %)**"AT+CALNTU=8" downlink:0xFE 08 **(%%)800NTU turbidity solution 1187 1187 1188 -(% style="color:#4472c4" %)**"AT+CALNTU=10" downlink:0xFE 0A 1185 +(% style="color:#4472c4" %)**"AT+CALNTU=10" downlink:0xFE 0A **(%%)1000NTU turbidity solution 1189 1189 1190 1190 1191 1191 ... ... @@ -1197,232 +1197,21 @@ 1197 1197 * Do not connect the wires with power on. After the wiring is completed and checked, power can be turned on. 1198 1198 * Do not arbitrarily change the components or wires that have been welded at the factory when using the product. 1199 1199 * The sensor is a precision device. When using it, please do not disassemble it by yourself or contact the sensor surface with sharp objects or corrosive liquids to avoid damaging the product. 1197 +* Do not power on while connect the cables. Double check the wiring before power on 1200 1200 1201 1201 1202 -Do not power on while connect the cables. Double check the wiring before power on 1203 1203 1204 1204 1205 1205 1206 -== 6.6 Total Solar Radiation sensor ~-~- WSS-06 == 1207 - 1208 - 1209 -((( 1210 -WSS-06 is Total Radiation Sensor can be used to measure the total solar radiation in the spectral range of 0.3 to 3 μm (300 to 3000 nm). If the sensor face is down, the reflected radiation can be measured, and the shading ring can also be used to measure the scattered radiation. 1211 -))) 1212 - 1213 -((( 1214 -The core device of the radiation sensor is a high-precision photosensitive element, which has good stability and high precision; at the same time, a precision-machined PTTE radiation cover is installed outside the sensing element, which effectively prevents environmental factors from affecting its performance 1215 -))) 1216 - 1217 -((( 1218 -WSS-06 is designed to support the Dragino Weather station solution. Users only need to connect WSS-06 RS485 interface to WSC1-L. The weather station main processor WSC1-L can detect and upload Total Solar Radiation to the IoT Server via wireless LoRaWAN protocol. 1219 -))) 1220 - 1221 - 1222 -=== 6.6.1 Feature === 1223 - 1224 - 1225 -* RS485 Total Solar Radiation sensor 1226 -* Measure Total Radiation between 0.3 ~~ 3μm(300 ~~ 3000nm) 1227 -* Measure Reflected Radiation if sense area towards ground. 1228 - 1229 -=== 6.6.2 Specification === 1230 - 1231 - 1232 -* Input Power: DC 5 ~~ 24v 1233 -* Interface: RS485 1234 -* Detect spectrum: 0.3 ~~ 3μm(300~3000nm) 1235 -* Measure strength range: 0 ~~ 2000W/m2 1236 -* Resolution: 0.1W/m2 1237 -* Accuracy: ±3% 1238 -* Yearly Stability: ≤±2% 1239 -* Cosine response: ≤7% (@ Sun angle 10°) 1240 -* Temperature Effect: ±2% (-10℃ ~~ 40℃) 1241 -* Working Temperature: -40℃ ~~ 70℃ 1242 -* Working Humidity: 10 ~~ 90%RH 1243 -* Power Consumption: 4mA @ 12v 1244 - 1245 -=== 6.6.3 Dimension === 1246 - 1247 - 1248 -[[image:1656057348695-898.png]] 1249 - 1250 - 1251 -=== 6.6.4 Pin Mapping === 1252 - 1253 - 1254 -[[image:1656057359343-744.png]] 1255 - 1256 - 1257 -=== 6.6.5 Installation Notice === 1258 - 1259 - 1260 -Do not power on while connect the cables. Double check the wiring before power on. 1261 - 1262 -[[image:1656057369259-804.png]] 1263 - 1264 -[[image:1656057377943-564.png]] 1265 - 1266 - 1267 -== 6.7 PAR (Photosynthetically Available Radiation) ~-~- WSS-07 == 1268 - 1269 - 1270 -((( 1271 -WSS-07 photosynthetically active radiation sensor is mainly used to measure the photosynthetically active radiation of natural light in the wavelength range of 400-700nm. 1272 -))) 1273 - 1274 -((( 1275 -WSS-07 use precision optical detectors and has an optical filter of 400-700nm, when natural light is irradiated, a voltage signal proportional to the intensity of the incident radiation is generated, and its luminous flux density is proportional to the cosine of the direct angle of the incident light. 1276 -))) 1277 - 1278 -((( 1279 -WSS-07 is designed to support the Dragino Weather station solution. Users only need to connect WSS-07 RS485 interface to WSC1-L. The weather station main processor WSC1-L can detect and upload Photosynthetically Available Radiation to the IoT Server via wireless LoRaWAN protocol. 1280 -))) 1281 - 1282 - 1283 -=== 6.7.1 Feature === 1284 - 1285 - 1286 -((( 1287 -PAR (Photosynthetically Available Radiation) sensor measure 400 ~~ 700nm wavelength nature light's Photosynthetically Available Radiation. 1288 -))) 1289 - 1290 -((( 1291 -When nature light shine on the sense area, it will generate a signal base on the incidence radiation strength. 1292 -))) 1293 - 1294 - 1295 -=== 6.7.2 Specification === 1296 - 1297 - 1298 -* Input Power: DC 5 ~~ 24v 1299 -* Interface: RS485 1300 -* Response Spectrum: 400~~700nm 1301 -* Measure range: 0 ~~ 2500μmol/m2•s 1302 -* Resolution: 1μmol/m2•s 1303 -* Accuracy: ±2% 1304 -* Yearly Stability: ≤ ±2% 1305 -* Working Temperature: -30℃ ~~ 75℃ 1306 -* Working Humidity: 10 ~~ 90%RH 1307 -* Power Consumption: 3mA @ 12v 1308 - 1309 -=== 6.7.3 Dimension === 1310 - 1311 - 1312 -[[image:1656057538793-888.png]] 1313 - 1314 - 1315 -=== 6.7.4 Pin Mapping === 1316 - 1317 - 1318 -[[image:1656057548116-203.png]] 1319 - 1320 - 1321 -=== 6.7.5 Installation Notice === 1322 - 1323 - 1324 -Do not power on while connect the cables. Double check the wiring before power on. 1325 - 1326 -[[image:1656057557191-895.png]] 1327 - 1328 -[[image:1656057565783-251.png]] 1329 - 1330 - 1331 1331 = 7. FAQ = 1332 1332 1333 -== 7.1 What else do I need to purchase to build Weather Station? == 1334 1334 1335 1335 1336 - Belowistheinstallationphoto and structure:1207 += 8. Order Info = 1337 1337 1209 +== 8.1 Main Process Unit == 1338 1338 1339 -[[image:1656057598349-319.png]] 1340 1340 1341 - 1342 -[[image:1656057608049-693.png]] 1343 - 1344 - 1345 -== 7.2 How to upgrade firmware for WSC1-L? == 1346 - 1347 - 1348 -((( 1349 -Firmware Location & Change log: [[https:~~/~~/www.dropbox.com/sh/j6uco1uirwqbng1/AAAwGoxamL5xNJR5Z6CTqGXha?dl=0>>https://www.dropbox.com/sh/j6uco1uirwqbng1/AAAwGoxamL5xNJR5Z6CTqGXha?dl=0]] 1350 -))) 1351 - 1352 -((( 1353 -Firmware Upgrade instruction: [[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome||anchor="H2.HardwareUpgradeMethodSupportList"]] 1354 -))) 1355 - 1356 - 1357 -== 7.3 How to change the LoRa Frequency Bands/Region? == 1358 - 1359 - 1360 -User can follow the introduction for how to [[upgrade image>>||anchor="H7.2HowtoupgradefirmwareforWSC1-L3F"]]. When download the images, choose the required image file for download. 1361 - 1362 - 1363 -== 7.4 Can I add my weather sensors? == 1364 - 1365 - 1366 -Yes, connect the sensor to RS485 bus and see instruction: [[add sensors.>>||anchor="H3.3AddorDeleteRS485Sensor"]] 1367 - 1368 - 1369 -== 7.5 Where can i find the modbus command for the WSS sensors? == 1370 - 1371 - 1372 -See this link for the [[modbus command set>>https://www.dropbox.com/s/rw90apbar029a4w/Weather_Sensors_Modbus_Command_List.xlsx?dl=0]]. 1373 - 1374 - 1375 -== 7.6 How to change the data read by the rain gauge? == 1376 - 1377 - 1378 -Users can run the AT+RAINFALLSWITCH command to query the data of the rain gauge. 1379 - 1380 -AT+RAINFALLSWITCH=10(Range: 3,4,5,6,8,10) 1381 - 1382 -**Rainfall query value:** 1383 - 1384 -3:The total rainfall after the sensor is powered on (for example Total rainfall: 166.5mm) 1385 - 1386 -4:Current Hourly rainfall: etc 0.2mm 1387 - 1388 -5:Rainfall in last hour: etc 0.2mm 1389 - 1390 -6:24-hour maximum rainfall: etc 10.0mm 1391 - 1392 -8:24-hour minimum rainfall: etc 0.0mm 1393 - 1394 -10:Rainfall in 24 hours: 8.0mm (Rainfall in the last 24 hours) 1395 - 1396 - 1397 -= 8. Trouble Shooting = 1398 - 1399 -== 8.1 AT Command input doesn't work == 1400 - 1401 - 1402 -((( 1403 -In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1404 -))) 1405 - 1406 - 1407 -== 8.2 Possible reasons why the device is unresponsive: == 1408 - 1409 - 1410 -~1. Check whether the battery voltage is lower than 2.8V 1411 -2. Check whether the jumper of the device is correctly connected 1412 - 1413 -[[image:image-20240330173709-1.png]] 1414 - 1415 - 1416 -3. Check whether the switch here of the device is at the ISP(The switch can operate normally only when it is in RUN) 1417 - 1418 -[[image:image-20240330173724-2.png]] 1419 - 1420 - 1421 -= 9. Order Info = 1422 - 1423 -== 9.1 Main Process Unit == 1424 - 1425 - 1426 1426 Part Number: (% style="color:blue" %)**WSC1-L-XX** 1427 1427 1428 1428 (% style="color:blue" %)**XX**(%%): The default frequency band ... ... @@ -1436,7 +1436,7 @@ 1436 1436 * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1437 1437 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1438 1438 1439 -== 9.2 Sensors ==1225 +== 8.2 Sensors == 1440 1440 1441 1441 1442 1442 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:500px" %) ... ... @@ -1450,7 +1450,7 @@ 1450 1450 |(% style="width:462px" %)Total Solar Radiation Sensor|(% style="width:120px" %)WSS-06 1451 1451 |(% style="width:462px" %)PAR (Photosynthetically Available Radiation)|(% style="width:120px" %)WSS-07 1452 1452 1453 -= 10. Support =1239 += 9. Support = 1454 1454 1455 1455 1456 1456 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. ... ... @@ -1457,7 +1457,7 @@ 1457 1457 1458 1458 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]. 1459 1459 1460 -= 1 1. Appendix I: Field Installation Photo =1246 += 10. Appendix I: Field Installation Photo = 1461 1461 1462 1462 1463 1463 [[image:1656058346362-132.png||height="685" width="732"]]