Changes for page WQS-NB/NS -- NB-IoT Water Quality Sensor Transmitter User Manual
Last modified by kai on 2025/08/06 10:05
From version 138.1
edited by Karry Zhuang
on 2024/07/16 11:54
on 2024/07/16 11:54
Change comment:
There is no comment for this version
To version 139.1
edited by Karry Zhuang
on 2024/07/17 10:21
on 2024/07/17 10:21
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -241,7 +241,7 @@ 241 241 0x02=2 (0x14: No Sensor, 0x15: Value Error) 242 242 ))) 243 243 ))) 244 -|(% style="width:135px" %)EC K1Sensor|(% style="width:51px" %)0x01|(% style="width:158px" %)((( 244 +|(% style="width:135px" %)EC K1 Sensor|(% style="width:51px" %)0x01|(% style="width:158px" %)((( 245 245 Angel: 0 ~~ 360° 246 246 Direction: 16 positions 247 247 )))|(% style="width:122px" %)0x03|(% style="width:904px" %)((( ... ... @@ -728,7 +728,13 @@ 728 728 729 729 730 730 ((( 731 -PH01 is a device for measuring the pH value (hydrogen ion concentration index, acidity and alkalinity) of a solution. It adopts an integrated design, is lighter and simpler in structure, and is more convenient to use. The waterproof grade is IP68. The reference electrode adopts a double salt bridge design, which has stronger anti-pollution ability. This product is suitable for industrial sewage, domestic sewage, agriculture, aquaculture and other scenes in non-corrosive weak acid and weak alkali environments. 731 +PH01 is a device for measuring the pH value (hydrogen ion concentration index, acidity and alkalinity) of a solution. 732 + 733 +It adopts an integrated design, is lighter and simpler in structure, and is more convenient to use. The waterproof grade is IP68. 734 + 735 +The reference electrode adopts a double salt bridge design, which has stronger anti-pollution ability. 736 + 737 +This product is suitable for industrial sewage, domestic sewage, agriculture, aquaculture and other scenes in non-corrosive weak acid and weak alkali environments. 732 732 ))) 733 733 734 734 ... ... @@ -841,8 +841,10 @@ 841 841 842 842 843 843 844 -EC K1/K10 is a device for measuring the conductivity of solutions. EC K1/K10 adopts an integrated design, which is lighter and simpler in structure and more convenient to use. The waterproof grade is IP68. It can be widely used in continuous monitoring of the conductivity of aqueous solutions such as cross-section water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food and tap water.850 +EC K1/K10 is a device for measuring the conductivity of solutions. EC K1/K10 adopts an integrated design, which is lighter and simpler in structure and more convenient to use. 845 845 852 +The waterproof grade is IP68. It can be widely used in continuous monitoring of the conductivity of aqueous solutions such as cross-section water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food and tap water. 853 + 846 846 ((( 847 847 848 848 ))) ... ... @@ -887,7 +887,6 @@ 887 887 888 888 (% style="color:#4472c4" %)**Electrode installation form** 889 889 890 - 891 891 A:Side wall installation 892 892 893 893 B:Top flange installation ... ... @@ -902,12 +902,10 @@ 902 902 903 903 [[image:image-20240716104537-2.png||height="475" width="706"]] 904 904 905 - 906 906 (% style="color:#4472c4" %)**Several common installation methods of electrodes** 907 907 908 908 When installing the sensor on site, you should strictly follow the correct installation method shown in the following picture. Incorrect installation method will cause data deviation. 909 909 910 - 911 911 A. Several common incorrect installation methods 912 912 913 913 === [[image:image-20240716105036-3.png||height="356" width="648"]] === ... ... @@ -919,7 +919,6 @@ 919 919 920 920 Error cause: Measurement error or instability may occur due to water flow not being able to fill the pipe or air accumulation at high altitudes. 921 921 922 - 923 923 B. Correct installation method 924 924 925 925 [[image:image-20240716105318-5.png||height="330" width="594"]] ... ... @@ -934,7 +934,6 @@ 934 934 * The equipment should be calibrated before each use. It is recommended to calibrate it every 3 months for long-term use. The calibration frequency should be adjusted appropriately according to different application conditions (degree of dirt in the application, deposition of chemical substances, etc.). 935 935 936 936 937 - 938 938 === 6.2.6 Calibration === 939 939 940 940 ... ... @@ -951,59 +951,48 @@ 951 951 (% style="color:#4472c4" %)**"AT+CALEC=10" downlink:0xFD 10** 952 952 953 953 954 -== 6.3 CO2/PM2.5/PM10~-~-WSS-03==957 +== 6.3 ORP Sensor ~-~- == 955 955 956 956 957 957 ((( 958 -WSS-03 is a RS485 Air Quality sensor. It can monitor CO2, PM2.5 and PM10 at the same time. 959 -))) 961 +ORP01 is a device for measuring the redox potential of a solution. It uses high-purity platinum to make an ORP composite electrode, which has strong acid and alkali resistance and antioxidant capacity, and has high measurement accuracy, fast response, and good stability. 960 960 961 -((( 962 -WSS-03 uses weather proof shield which can make sure the sensors are well protected against UV & radiation. 963 +The electrode can automatically compensate according to temperature. It is suitable for online monitoring of the redox potential of cyanide-containing and chromium-containing wastewater. 963 963 ))) 964 964 965 -((( 966 -WSS-03 is designed to support the Dragino Weather station solution. Users only need to connect WSS-03 RS485 interface to WSC1-L. The weather station main processor WSC1-L can detect and upload the environment CO2, PM2.5 and PM10 to the IoT Server via wireless LoRaWAN protocol. 967 -))) 968 968 969 - 970 970 === 6.3.1 Feature === 971 971 972 972 973 -* RS485 CO2, PM2.5, PM10 sensor 974 -* NDIR to measure CO2 with Internal Temperature Compensation 975 -* Laser Beam Scattering to PM2.5 and PM10 970 +* ORP measurement range -1999~~1999mV, resolution 1mV. 971 +* Applicable electrode temperature 0~~80℃. 972 +* The electrode is made of high-purity platinum, which has strong acid and alkali resistance and antioxidant capacity, high measurement accuracy, fast response and good stability. 973 +* RS485 communication interface: ModBus-RTU communication protocol can be easily connected to the computer for monitoring and communication. 974 +* ModBus communication address can be set and baud rate can be modified. 975 +* The equipment adopts wide voltage power supply, DC 7~~30V 976 976 977 977 === 6.3.2 Specification === 978 978 979 979 980 -* CO2 Range: 0 ~~ 5000ppm, accuracy: ±3%F•S(25℃) 981 -* CO2 resolution: 1ppm 982 -* PM2.5/PM10 Range: 0 ~~ 1000μg/m3 , accuracy ±3%F•S(25℃) 983 -* PM2.5/PM10 resolution: 1μg/m3 984 -* Input Power: DC 7 ~~ 24v 985 -* Preheat time: 3min 986 -* Interface: RS485 987 -* Working Temperature: 988 -** CO2: 0℃ ~~ 50℃; 989 -** PM2.5/PM10: -30 ~~ 50℃ 990 -* Working Humidity: 991 -** PM2.5/PM10: 15 ~~ 80%RH (no dewing) 992 -** CO2: 0 ~~ 95%RH 993 -* Power Consumption: 50mA@ 12v. 980 +* Measuring range: -1999~~1999mV 981 +* Resolution: 1mV 982 +* Output signal: RS485 983 +* Measurement error: ±3mV 984 +* Stability: ≤2mv/24 hours 985 +* Equipment working conditions: Ambient temperature: 0-60℃ Relative humidity: <85%RH 986 +* Waterproof grade: IP68 987 +* Pressure resistance: 0.6MP 994 994 995 995 === 6.3.3 Dimension === 996 996 997 997 998 -[[image:1656056708366-230.png]] 999 999 993 +[[image:image-20240715181651-3.png||height="223" width="562"]] 1000 1000 1001 1001 === 6.3.4 Pin Mapping === 1002 1002 1003 1003 1004 -[[image:1656056722648-743.png]] 1005 1005 1006 - 1007 1007 === 6.3.5 Installation Notice === 1008 1008 1009 1009