Changes for page WQS-NB/NS -- NB-IoT Water Quality Sensor Transmitter User Manual
Last modified by kai on 2025/08/06 10:05
From version 137.1
edited by Karry Zhuang
on 2024/07/16 10:53
on 2024/07/16 10:53
Change comment:
Uploaded new attachment "image-20240716105318-5.png", version {1}
To version 137.2
edited by Karry Zhuang
on 2024/07/16 10:53
on 2024/07/16 10:53
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -779,7 +779,7 @@ 779 779 The lead wire of the equipment passes through the waterproof pipe, and the 3/4 thread on the top of the equipment is connected to the 3/4 thread of the waterproof pipe with raw tape. Ensure that the top of the equipment and the equipment wire are not flooded. 780 780 781 781 782 -[[image:image-20240715181933-4.png||height="2 67" width="245"]]782 +[[image:image-20240715181933-4.png||height="281" width="258"]] 783 783 ))) 784 784 785 785 ... ... @@ -791,7 +791,7 @@ 791 791 Connect the equipment to the pipeline through the 3/4 thread. 792 792 ))) 793 793 794 -[[image:image-20240715182122-6.png]] 794 +[[image:image-20240715182122-6.png||height="291" width="408"]] 795 795 796 796 797 797 (% style="color:#4472c4" %)**Sampling:** ... ... @@ -819,7 +819,6 @@ 819 819 The equipment should be calibrated before each use. For long-term use, it is recommended to calibrate once every 3 months. The calibration frequency should be adjusted appropriately according to different application conditions (degree of dirt in the application, deposition of chemical substances, etc.). After aging, the electrodes should be replaced in time. 820 820 ))) 821 821 822 - 823 823 === 6.1.6 Calibration === 824 824 825 825 ... ... @@ -841,54 +841,95 @@ 841 841 == 6.2 EC Sensor == 842 842 843 843 844 -[[image:1656055444035-179.png]] 845 845 844 +EC K1/K10 is a device for measuring the conductivity of solutions. EC K1/K10 adopts an integrated design, which is lighter and simpler in structure and more convenient to use. The waterproof grade is IP68. It can be widely used in continuous monitoring of the conductivity of aqueous solutions such as cross-section water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food and tap water. 846 846 847 847 ((( 848 - WSS-02is a RS485 wind speed and wind direction monitor designed for weather station solution.847 + 849 849 ))) 850 850 851 -((( 852 -WSS-02 shell is made of polycarbonate composite material, which has good anti-corrosion and anti-corrosion characteristics, and ensure the long-term use of the sensor without rust. At the same time, it cooperates with the internal smooth bearing system to ensure the stability of information collection 853 -))) 854 854 855 -((( 856 -Users only need to connect WSS-02 RS485 interface to WSC1-L. The weather station main processor WSC1-L can detect and upload the wind speed and direction to the IoT Server via wireless LoRaWAN protocol. 857 -))) 858 - 859 - 860 860 === 6.2.1 Feature === 861 861 862 862 863 -* RS485 wind speed / direction sensor 864 -* PC enclosure, resist corrosion 854 +* Conductivity measurement range is 0-2000us/cm; 10~~20000us/cm. 855 +* Integrated design, light and simple structure, easy to use. 856 +* Waterproof grade IP68. 857 +* With salinity and TDS conversion function. 858 +* RS485 communication interface: MDDBUS RTU communication protocol can be easily connected to the computer for monitoring and communication. 859 +* ModBus communication address can be set and baud rate can be modified. 860 +* The device adopts wide voltage power supply, DC 7~~30V is available. 865 865 866 866 === 6.2.2 Specification === 867 867 868 868 869 -* Wind speed range: 0 ~~ 60m/s 870 -* Wind direction range: 0 ~~ 360° 871 -* Start wind speed: ≤0.3 m/s 872 -* Accuracy: ±(0.3+0.03V) m/s , ±1° 873 -* Input Power: DC 5 ~~ 24v 874 -* Interface: RS485 875 -* Working Temperature: -30℃ ~~ 70℃ 876 -* Working Humidity: <100% (no dewing) 877 -* Power Consumption: 13mA ~~ 12v. 878 -* Cable Length: 2 meters 865 +* Power supply: DC7~~30V 866 +* Power consumption: ≤0.5W 867 +* Communication interface: RS485; standard MODBUS-RTU protocol; communication baud rate: default 9600 868 +* Conductivity measurement range: K=1: 1~~2000μs/cm; resolution: 1μs/cm K=10: 10~~20000μs/cm; resolution: 10μ 869 +* Conductivity measurement error: ±1%FS 870 +* Equipment working conditions: Ambient temperature: 0-60℃ 871 +* Waterproof grade: IP68 872 +* Pressure resistance: 0.6MPa 879 879 880 880 === 6.2.3 Dimension === 881 881 882 882 883 -[[image:image-202 20624152813-2.png]]877 +[[image:image-20240715181651-3.png||height="223" width="562"]] 884 884 885 885 886 -=== 6.2.4 PinMapping===880 +=== 6.2.4 Installation Notice === 887 887 888 888 889 - [[image:1656056281231-994.png]]883 +Selection of matching electrode constant 890 890 885 +[[image:image-20240716104100-1.png||height="349" width="641"]] 891 891 887 + 888 +(% style="color:#4472c4" %)**Electrode installation form** 889 + 890 + 891 +A:Side wall installation 892 + 893 +B:Top flange installation 894 + 895 +C:Pipeline bend installation 896 + 897 +D:Pipeline bend installation 898 + 899 +E:Flow-through installation 900 + 901 +F:Submerged installation 902 + 903 +[[image:image-20240716104537-2.png||height="475" width="706"]] 904 + 905 + 906 +(% style="color:#4472c4" %)**Several common installation methods of electrodes** 907 + 908 +When installing the sensor on site, you should strictly follow the correct installation method shown in the following picture. Incorrect installation method will cause data deviation. 909 + 910 + 911 +A. Several common incorrect installation methods 912 + 913 +=== [[image:image-20240716105036-3.png||height="356" width="648"]] === 914 + 915 +Error cause: The electrode joint is too long, the extension part is too short, the sensor is easy to form a dead cavity, resulting in measurement error. 916 + 917 + 918 +[[image:image-20240716105124-4.png||height="326" width="569"]] 919 + 920 +Error cause: Measurement error or instability may occur due to water flow not being able to fill the pipe or air accumulation at high altitudes. 921 + 922 + 923 +B. Correct installation method 924 + 925 +[[image:image-20240716105318-5.png||height="330" width="594"]] 926 + 927 + 928 + 929 + 930 + 931 + 892 892 === 6.2.5 Angle Mapping === 893 893 894 894