Last modified by Xiaoling on 2025/04/27 16:48

From version 78.5
edited by Xiaoling
on 2022/10/14 14:13
Change comment: There is no comment for this version
To version 70.1
edited by Edwin Chen
on 2022/10/09 23:47
Change comment: Uploaded new attachment "image-20221009234703-2.png", version {1}

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Edwin
Content
... ... @@ -209,11 +209,9 @@
209 209  === 2.4.1 Uplink FPORT~=5, Device Status ===
210 210  
211 211  
212 -Uplink the device configures with FPORT=5. Once TrackerD Joined the network, it will uplink this message to the server. After the first uplink, TrackerD will uplink Device Status every 12 hours.
212 +Uplink the device configures with FPORT=5. Once LGT92 Joined the network, it will uplink this message to the server. After first uplink, LHT52 will uplink Device Status every 12 hours.
213 213  
214 -Use can also get the Device Status uplink through the downlink command: **Downlink:  0x2301**
215 215  
216 -
217 217  (% border="1.5" style="background-color:#ffffcc; color:green; width:520px" %)
218 218  |=(% scope="row" style="width: 108px;" %)**Size(bytes)**|=(% style="width: 82px;" %)**1**|=(% style="width: 83px;" %)**2**|=(% style="width: 94px;" %)**1**|=(% style="width: 84px;" %)**1**|=(% style="width: 44px;" %)2|=(% style="width: 63px;" %)**2**|=(% style="width: 60px;" %)1
219 219  |=(% style="width: 108px;" %)**Value**|(% style="width:82px" %)Sensor Model|(% style="width:83px" %)Firmware Version|(% style="width:94px" %)Frequency Band|(% style="width:84px" %)Sub-band|(% style="width:44px" %)BAT|(% style="width:63px" %)SMOD|(% style="width:60px" %)Status
... ... @@ -221,13 +221,13 @@
221 221  [[image:1665301570342-765.png]]
222 222  
223 223  
224 -(% style="color:#037691" %)**Example of Device Status:**(%%) 13014001FF0FA24002
222 +Example Payload (FPort=5):  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT52%20-%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220621105116-11.png?rev=1.1||alt="image-20220621105116-11.png"]]
225 225  
226 -(% style="color:#037691" %)**Sensor Model:** (%%) For TrackerD,this value is 0x13
224 +**Sensor Model**: For TrackerD, this value is 0x13.
227 227  
228 -(% style="color:#037691" %)**Firmware Version: **(%%) 0x0140,Means:v1.4.0 version
226 +**Firmware Version**: 0x0100, Means: v1.0.0 version.
229 229  
230 -(% style="color:#037691" %)**Frequency Band**:
228 +**Frequency Band**:
231 231  
232 232  *0x01: EU868
233 233  
... ... @@ -249,56 +249,20 @@
249 249  
250 250  *0x0a: AS923-3
251 251  
252 -Sub- Band:value 0x00~~0x08(only forAU915,US915,Others are 0xFF)
250 +**Sub-Band**: value 0x00 ~~ 0x08(only for CN470, AU915,US915. Others are0x00)
253 253  
254 -(% style="color:#037691" %)**BAT:**(%%) shows the battery voltage for TrackerD.
252 +**BAT**: shows the battery voltage for TrackerD.
255 255  
254 +Ex1: 0x0B3A = 2874mV
256 256  
257 -(% style="color:#037691" %)**Ex1:**(%%) 0x0FA2 = 4002mV
258 -
259 259  Use can also get the Device Status uplink through the downlink command:
260 260  
261 261  
262 262  
263 -(% style="color:#037691" %)**SMOD Field (total 1 byte)**(%%):0x40
264 -
265 -(% border="1.5" style="background-color:#ffffcc; color:green; width:420px" %)
266 -|(% style="width:75px" %)**Size(bit)**|(% style="width:64px" %)2bits|(% style="width:137px" %)2bit|(% style="width:142px" %)4bit
267 -|(% style="width:75px" %)**Value**|(% style="width:64px" %)SMOD|(% style="width:137px" %)GPS_Settings|(% style="width:142px" %)BLE_Settings
268 -
269 -(% style="color:blue" %)** SMOD:**
270 -
271 -(% style="color:red" %)** 1 :** (%%) GPS ONLY
272 -
273 -(% style="color:red" %)** 2 :** (%%) BLE ONLY
274 -
275 -(% style="color:red" %)** 3 :**  (%%) GPS/BLE Hybrid
276 -
277 -
278 -(% style="color:blue" %)** GPS_MOD: Define how to send GPS payload**
279 -
280 -(% style="color:red" %)** 0 : ** (%%) Enable uploading on-board Temperature and humidity values
281 -
282 -(% style="color:red" %)** 1 :** (%%) Disable uploading on-board Temperature and humidity values
283 -
284 -
285 -(% style="color:blue" %)** BLE_Settings:**
286 -
287 -(% style="color:red" %)** 1: ** (%%) BLE Positioning with Strongest iBeacon
288 -
289 -
290 -
291 -(% style="color:#037691" %)**Status Field (total 1 byte)**(%%):  0x02
292 -
293 -(% border="1.5" style="background-color:#ffffcc; color:green; width:417px" %)
294 -|(% style="width:77px" %)**Size(bit)**|(% style="width:70px" %)5 Bits|(% style="width:92px" %)1 Bit|(% style="width:48px" %)1 Bit|(% style="width:126px" %)1 Bit
295 -|(% style="width:77px" %)**Value**|(% style="width:70px" %)Reserve|(% style="width:92px" %)[[PNACKMD>>||anchor="H2.4.4A0UplinkFPORT3D42CHistoryGNSSPositioning"]]|(% style="width:48px" %)[[LON>>||anchor="H3.2.5Disable2FEnableLEDflash"]]|(% style="width:126px" %)[[Transport Mode>>||anchor="H2.9TransportMode"]]
296 -
297 -
298 298  === 2.4.2 Uplink FPORT~=2, Realtime GNSS Positioning + Temperature & Humidity ===
299 299  
300 300  
301 -Users can use **AT+SMOD=1,0,0** to enable uploading on-board Temperature and humidity values, and the total payload will be 15 bytes,
263 +User can use **AT+SMOD=1,0** to enable uploading on-board Temperature and humidity values, and the total payload will be 15 bytes, please note that 15 bytes won't work on DR0 on US915/AU915 frequency band.
302 302  
303 303  
304 304  (% border="1.2" cellspacing="3" style="background-color:#ffffcc; color:green; width:480px" %)
... ... @@ -322,7 +322,12 @@
322 322  |=(% scope="row" style="width: 50px;" %)**Size(bit)**|(% style="width:50px" %)1 bit|(% style="width:80px" %)1bit|(% style="width:50px" %)14bits
323 323  |=(% style="width: 72px;" %)**Value**|(% style="width:67px" %)reserve|(% style="width:118px" %)Alarm Indicate|(% style="width:63px" %)[[BAT>>||anchor="HBAT:"]] 
324 324  
287 +(% class="wikigeneratedid" %)
288 +==== ====
325 325  
290 +(% class="wikigeneratedid" %)
291 +==== ====
292 +
326 326  ==== (% style="color:blue" %)**FLAG:**(%%) ====
327 327  
328 328  (% border="1.2" cellspacing="3" style="background-color:#ffffcc; color:green; width:250px" %)
... ... @@ -338,6 +338,7 @@
338 338  * Longitude: FAC29BAF  ⇒ //if (0x//FAC29BAF// & 0x80000000 = 1 )~://  //value = (0x//FAC29BAF// – 0x 100000000)/1000000 =//-87.9094//57//
339 339  
340 340  
308 +
341 341  (% style="color:red" %)**Important note:**
342 342  
343 343  1.  When power is low (<2.84v), GPS won't be able to get location info and GPS feature will be disabled and the location field will be filled with 0x0FFFFFFF, 0x0FFFFFFF.
... ... @@ -356,12 +356,13 @@
356 356  
357 357  ==== (% style="color:blue" %)**Alarm:**(%%) ====
358 358  
359 -**Example: ** 0x4B & 0x40 >> 6 = 0x01
327 +Example:  0x4B & 0x40 >> 6 = 0x01
360 360  
361 361  
330 +
362 362  ==== (% style="color:blue" %)**BAT:**(%%) ====
363 363  
364 -**Example: ** 0x4B45 & 0x3FFF ⇒ 2885 (mV).
333 +Example:  0x0CDD & 0x3FFF ⇒ 3293 (mV).
365 365  
366 366  (((
367 367  The battery info shows the battery voltage, User can use the below mapping to indicate the battery in percentage: \
... ... @@ -375,37 +375,19 @@
375 375  
376 376  
377 377  
378 -==== (% style="color:blue" %)**MOD:**(%%) ====
379 -
380 -**Example: ** (0x60>>6)& 0x3f =1.
381 -
382 -**Set the format of GPS data uplink link:**
383 -
384 -(% style="color:#037691" %)**0x00:** (%%) Enable uploading on-board Temperature and humidity values
385 -(% style="color:#037691" %)**0x01: ** (%%) Disable uploading on-board Temperature and humidity values
386 -
387 -
388 -**Set the format of BLE data uplink link:**
389 -
390 -(% style="color:#037691" %)**0x01: ** (%%) BLE Positioning with Strongest iBeacon
391 -
392 -
393 393  ==== (% style="color:blue" %)**LON:**(%%) ====
394 394  
395 -**Example:** (0x60>>5) & 0x01=1.
396 -
397 397  Enable/Disable LED activity for uplink
398 398  
399 399  (((
400 -(% style="color:#037691" %)**0x00:**  (%%) Disable LED indicator.
352 +0x00:  Disable LED indicator.
401 401  )))
402 402  
403 403  (((
404 -(% style="color:#037691" %)**0x01:**  (%%) Enable LED indicator (Default Value)
356 +0x01:  Enable LED indicator (Default Value)
405 405  )))
406 406  
407 407  
408 -
409 409  ==== (% style="color:blue" %)**Hum:**(%%) ====
410 410  
411 411  0202 = //if (0x0202 & 0x8000 = 0 ):  value =// 0x0202 / 100 = +514 ⇒ 51.4 degree
... ... @@ -420,7 +420,7 @@
420 420  === 2.4.3  Uplink FPORT~=3, Realtime GNSS Positioning (Default Mode) ===
421 421  
422 422  
423 -The default uplink payload includes total 11 bytes (**AT+SMOD=1,1,0**). The payload is the first 11 bytes of Uplink FPORT=2, real-time GNSS positioning, (remove the temp and humidity)
374 +The default uplink payload includes totally 11 bytes. The payload is the first 11 bytes of Uplink FPORT=2, real-time GNSS positioning, (remove the temp and humidity)
424 424  
425 425  
426 426  (% border="1.2" cellspacing="3" style="background-color:#ffffcc; color:green; width:480px" %)
... ... @@ -439,7 +439,7 @@
439 439  === 2.4.4  Uplink FPORT~=4, History GNSS Positioning ===
440 440  
441 441  
442 -Set [[PNACKMD=1>>||anchor="H3.2.10A0A0AutoSendNone-ACKmessages"]], and TrackerD will wait for ACK for every uplink, when there is no LoRaWAN network, TrackerD will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
393 +Set [[PNACKMD=1>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H4.13AutoSendNone-ACKmessages]], and TrackerD will wait for ACK for every uplink, when there is no LoRaWAN network, TrackerD will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
443 443  
444 444  
445 445  (% style="color:red" %)**Note for this mode:**
... ... @@ -446,7 +446,6 @@
446 446  
447 447  * a) TrackerD will do an ACK check for data records sending to make sure every data arrive server.
448 448  * b) TrackerD will send data in (% style="color:blue" %)**CONFIRMED Mode**(%%) when PNACKMD=1, but TrackerD won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink, if TrackerD gets an ACK, TrackerD will consider there is a network connection and resend all NONE-ACK Messages.
449 -* c) the total payload will be 15 bytes, while US915/AU915 DR0 accepts only 11 bytes of payload. In this case (DR0 of US915/AU915), the payload on server will show NULL
450 450  
451 451  The payload is 15 bytes, as below.
452 452  
... ... @@ -492,6 +492,7 @@
492 492  
493 493  
494 494  
445 +
495 495  === 2.4.6  Add Payload format in TTN V3 ===
496 496  
497 497  
... ... @@ -547,19 +547,10 @@
547 547  == 2.7  Datalog Feature ==
548 548  
549 549  
550 -total 273 entries,by default,
501 +total 273 entries,by default disable
551 551  
552 -User can set [[PNACKMD=1>>||anchor="H3.2.10A0A0AutoSendNone-ACKmessages"]], to enable Datalog feature.
553 553  
554 -Example use case.
555 555  
556 -[[image:image-20221009234703-2.png||height="328" width="899"]]
557 -
558 -
559 -[[image:image-20221009234629-1.png||height="390" width="577"]]
560 -
561 -
562 -
563 563  == 2.8 Alarm Mode ==
564 564  
565 565  
... ... @@ -611,6 +611,8 @@
611 611  |(% style="width:157px" %)**Movement Detect**|(% style="width:271px" %)(% style="color:red" %)**RED **(%%)led on 500ms|(% style="width:202px" %)N/A
612 612  
613 613  
556 +
557 +
614 614  == 2.11 Button Function ==
615 615  
616 616  
... ... @@ -633,6 +633,8 @@
633 633  |(% style="width:135px" %)Enter Deep Sleep Mode|(% style="width:220px" %)Press and hold the button for 10 seconds, then quickly press the device 3 times to enter deep sleep|(% style="width:265px" %)This is the mode ship out from factory. CPU will be complete in sleep mode and no LoRa activity, only use before deploy.
634 634  
635 635  
580 +
581 +
636 636  == 2.12 USB Port Function ==
637 637  
638 638  
... ... @@ -644,6 +644,8 @@
644 644  * [[Upgrade Firmware>>||anchor="H5.UploadFirmware"]]
645 645  
646 646  
593 +
594 +
647 647  = 3. Configure TrackerD via AT command or LoRaWAN downlink =
648 648  
649 649  
... ... @@ -791,33 +791,37 @@
791 791  
792 792  * (% style="color:blue" %)**AT Command:**
793 793  
794 -(% style="color:#037691" %)**AT+SMOD=aa,bb,cc**
742 +(% style="color:#037691" %)**AT+SMOD=aa,bb**
795 795  
796 796  (% style="color:#037691" %)** aa:**
797 797  
798 -* (% style="color:red" %)**1: GPS ONLY(Factory Settings):    **(%%)only get and uplink GPS location info.
799 -* (% style="color:red" %)**2: BLE ONLY:              **(%%)Only obtain iBeacon info via BLE and uplink. Design for Indoor tracking.
800 -* (% style="color:red" %)**3: GPS/BLE Hybrid:   **(%%)Combination for Indoor and Outdoor tracking.Devices will try to search BLE iBeacon first. If device can't find the iBeacon, it will use GPS for positioning.
746 +* (% style="color:#037691" %)**1: GPS ONLY(Factory Settings):    **(%%)only get and uplink GPS location info.
747 +* (% style="color:#037691" %)**2: BLE ONLY:              **(%%)Only obtain iBeacon info via BLE and uplink. Design for Indoor tracking.
748 +* (% style="color:#037691" %)**3: GPS/BLE Hybrid:   **(%%)Combination for Indoor and Outdoor tracking.Devices will try to search BLE iBeacon first. If device can't find the iBeacon, it will use GPS for positioning
801 801  
802 802  (% style="color:#037691" %)**bb:**
803 803  
804 -* (% style="color:red" %)**0 :  **(%%)GPS+ BAT+ State+Tem&Hum
805 -* (% style="color:red" %)**1 :**(%%)  GPS +BAT State
752 +(% style="color:#037691" %)** if aa = 1: **
806 806  
807 -(% style="color:#037691" %)**cc:   **
754 +* (% style="color:#037691" %)**0 :  **(%%)GPS+ BAT+ State+Tem&Hum
755 +* (% style="color:#037691" %)**1 :**(%%)  GPS +BAT State
808 808  
809 -* (% style="color:red" %)**1 : **(%%) (iBeacon)UUID+ Major + Minor+Power+Rssi+BAT+State  
757 +(% style="color:#037691" %)** if aa = 2: **
810 810  
811 -(% style="color:blue" %)**Example:**
759 +* (% style="color:#037691" %)**3 :  **(%%)(iBeacon)UUID+ Major + Minor+Power+Rssi+BAT+State
812 812  
813 - AT+ SMOD =1,0 ,0 ~-~->  GPS+ BAT+ State+Tem&Hum
814 - AT+ SMOD =1,1,0 ~-~->  GPS +BAT State
815 - AT+ SMOD =2,0,1 ~-~->  (iBeacon)UUID+ Major + Minor+Power+Rssi+BAT+State
761 + **Example:**
816 816  
763 + AT+ SMOD =1,0  **~-~-> ** GPS+ BAT+ State+Tem&Hum
817 817  
765 + AT+ SMOD =1,1    **~-~->**  GPS +BAT State
766 +
767 + AT+ SMOD =2,3    **~-~->**  (iBeacon)UUID+ Major + Minor+Power+Rssi+BAT+State
768 +
769 +
818 818  * (% style="color:blue" %)**Downlink Payload (prefix 0xA5):**
819 819  
820 -(% style="color:#037691" %)**0xA5 01 00 00**    (%%) ~/~/  Same as AT+ SMOD =1,0,0
772 +(% style="color:#037691" %)**0xA5 01 00**    (%%) ~/~/  Same as AT+ SMOD =1,0
821 821  
822 822  
823 823  
... ... @@ -834,7 +834,7 @@
834 834  
835 835  (% style="color:#037691" %)**AT+FTIME=xx**  (%%) **~-~-> ** Set to use xx as max fix time.
836 836  
837 -**Example:**  AT+FTIME=150
789 +Example:  AT+FTIME=150
838 838  
839 839  
840 840  * (% style="color:blue" %)**Downlink Payload (prefix 0xAA):**
... ... @@ -871,7 +871,7 @@
871 871  
872 872  * (% style="color:blue" %)**AT Command:**
873 873  
874 -(% style="color:#037691" %)**AT+CFM=xx**
826 +(% style="color:#037691" %)**AT+CFM=xx. **
875 875  
876 876  
877 877  **~ Example:**
... ... @@ -887,27 +887,6 @@
887 887  
888 888  
889 889  
890 -=== 3.2.10  Auto Send None-ACK messages ===
891 -
892 -
893 -TrackerD will wait for ACK for each uplink, If TrackerD doesn't get ACK from the IoT server, it will consider the message doesn't arrive server and store it. TrackerD keeps sending messages in normal periodically. Once TrackerD gets ACK from a server, it will consider the network is ok and start to send the not-arrive message.
894 -
895 -
896 -* (% style="color:blue" %)**AT Command: AT+PNACKMD**
897 -
898 -The default factory setting is 0.
899 -
900 -
901 -**Command Example Function Response:**
902 -
903 -(% style="color:#037691" %)**AT+PNACKMD=1**  (%%) ~/~/  Poll None-ACK message OK
904 -
905 -
906 -* (% style="color:blue" %)**Downlink Command: 0x34**
907 -
908 -Example: 0x3401  ~/~/  Same as AT+PNACKMD=1
909 -
910 -
911 911  = 4. Setting for Different Scenarios =
912 912  
913 913  
... ... @@ -950,7 +950,7 @@
950 950  
951 951  (% style="color:blue" %)**Step5:** (%%) Select the firmware file (.bin format), com port and proper SPI configure. Clink Start. Bin file location:
952 952  
953 -[[https:~~/~~/github.com/dragino/TrackerD/releases>>https://github.com/dragino/TrackerD/releases]]
884 +[[https:~~/~~/www.dropbox.com/sh/733s8xlwahhqg1d/AABxDz80lBVX_to8zNuUQWFja?dl=0>>url:https://www.dropbox.com/sh/733s8xlwahhqg1d/AABxDz80lBVX_to8zNuUQWFja?dl=0]]
954 954  
955 955  
956 956  Users need to use below files:
... ... @@ -1054,6 +1054,7 @@
1054 1054  
1055 1055  
1056 1056  
988 +
1057 1057  = 8.  Order Info =
1058 1058  
1059 1059  
... ... @@ -1071,6 +1071,7 @@
1071 1071  
1072 1072  
1073 1073  
1006 +
1074 1074  = 9.  Packing Info =
1075 1075  
1076 1076