Changes for page TrackerD -- LoRaWAN Tracker User Manual
Last modified by Xiaoling on 2025/04/27 16:48
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -339,7 +339,6 @@ 339 339 * Latitude: 02863D68 ⇒ //if (0x//02863D68//& 0x80000000 = 0 )~:// //value = 02863D68 /1000000 = 42.351976// 340 340 * Longitude: FAC29BAF ⇒ //if (0x//FAC29BAF// & 0x80000000 = 1 )~:// //value = (0x//FAC29BAF// – 0x 100000000)/1000000 =//-87.9094//57// 341 341 342 - 343 343 (% style="color:red" %)**Important note:** 344 344 345 345 1. When power is low (<2.84v), GPS won't be able to get location info and GPS feature will be disabled and the location field will be filled with 0x0FFFFFFF, 0x0FFFFFFF. ... ... @@ -363,7 +363,7 @@ 363 363 364 364 ==== (% style="color:blue" %)**BAT:**(%%) ==== 365 365 366 -Example: 4B45& 0x3FFF ⇒ 2885(mV).365 +Example: 0x0CDD & 0x3FFF ⇒ 3293 (mV). 367 367 368 368 ((( 369 369 The battery info shows the battery voltage, User can use the below mapping to indicate the battery in percentage: \ ... ... @@ -379,31 +379,23 @@ 379 379 380 380 ==== (% style="color:blue" %)**MOD:**(%%) ==== 381 381 382 -mo d=(0x60>>6)&0x3f;381 +Set the format of GPS data uplink link 383 383 384 - **Settheformatof GPSdata uplinklink:**383 +0x00: Enable uploading on-board Temperature and humidity values 385 385 386 -(% style="color:#037691" %)**0x00:** (%%) Enable uploading on-board Temperature and humidity values 387 -(% style="color:#037691" %)**0x01: ** (%%) Disable uploading on-board Temperature and humidity values 385 +0x01: Disable uploading on-board Temperature and humidity values 388 388 389 389 390 -**Set the format of BLE data uplink link:** 391 - 392 -(% style="color:#037691" %)**0x01: ** (%%) BLE Positioning with Strongest iBeacon 393 - 394 - 395 395 ==== (% style="color:blue" %)**LON:**(%%) ==== 396 396 397 -lon=(0x60>>5) & 0x01; 398 - 399 399 Enable/Disable LED activity for uplink 400 400 401 401 ((( 402 - (% style="color:#037691" %)**0x00:**(%%)Disable LED indicator.393 +0x00: Disable LED indicator. 403 403 ))) 404 404 405 405 ((( 406 - (% style="color:#037691" %)**0x01:**(%%)Enable LED indicator (Default Value)397 +0x01: Enable LED indicator (Default Value) 407 407 ))) 408 408 409 409 ... ... @@ -611,7 +611,6 @@ 611 611 612 612 613 613 614 - 615 615 == 2.11 Button Function == 616 616 617 617 ... ... @@ -635,7 +635,6 @@ 635 635 636 636 637 637 638 - 639 639 == 2.12 USB Port Function == 640 640 641 641 ... ... @@ -812,6 +812,7 @@ 812 812 813 813 * (% style="color:red" %)**1 : **(%%) (iBeacon)UUID+ Major + Minor+Power+Rssi+BAT+State 814 814 804 + 815 815 (% style="color:blue" %)**Example:** 816 816 817 817 AT+ SMOD =1,0 ,0 ~-~-> GPS+ BAT+ State+Tem&Hum ... ... @@ -875,7 +875,7 @@ 875 875 876 876 * (% style="color:blue" %)**AT Command:** 877 877 878 -(% style="color:#037691" %)**AT+CFM=xx** 868 +(% style="color:#037691" %)**AT+CFM=xx. ** 879 879 880 880 881 881 **~ Example:** ... ... @@ -891,27 +891,6 @@ 891 891 892 892 893 893 894 -=== 3.2.10 Auto Send None-ACK messages === 895 - 896 - 897 -TrackerD will wait for ACK for each uplink, If TrackerD doesn't get ACK from the IoT server, it will consider the message doesn't arrive server and store it. TrackerD keeps sending messages in normal periodically. Once TrackerD gets ACK from a server, it will consider the network is ok and start to send the not-arrive message. 898 - 899 - 900 -* (% style="color:blue" %)**AT Command: AT+PNACKMD** 901 - 902 -The default factory setting is 0. 903 - 904 - 905 -**Command Example Function Response:** 906 - 907 -(% style="color:#037691" %)**AT+PNACKMD=1** (%%) ~/~/ Poll None-ACK message OK 908 - 909 - 910 -* (% style="color:blue" %)**Downlink Command: 0x34** 911 - 912 -Example: 0x3401 ~/~/ Same as AT+PNACKMD=1 913 - 914 - 915 915 = 4. Setting for Different Scenarios = 916 916 917 917 ... ... @@ -1058,7 +1058,6 @@ 1058 1058 1059 1059 1060 1060 1061 - 1062 1062 = 8. Order Info = 1063 1063 1064 1064