Changes for page TrackerD -- LoRaWAN Tracker User Manual
Last modified by Xiaoling on 2025/04/14 16:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -678,8 +678,8 @@ 678 678 == 2.11 LED Status == 679 679 680 680 681 -(% border="1 " cellspacing="5" style="background-color:#f2f2f2; width:500px" %)682 -|=(% style="width: 150px; background-color:#D9E2F3;color:#0070C0" %)**Event**|=(% style="width: 200px;background-color:#D9E2F3;color:#0070C0" %)**Action**|=(% style="width: 150px;background-color:#D9E2F3;color:#0070C0" %)**AT+LON to control on/off**681 +(% border="1.5" style="background-color:#ffffcc; width:500px" %) 682 +|=(% style="width: 150px;" %)**Event**|=(% style="width: 200px;" %)**Action**|=(% style="width: 150px;" %)**AT+LON to control on/off** 683 683 |(% style="width:157px" %)**Power On**|(% style="width:271px" %)(% style="color:blue" %)**BLUE, **(% style="color:red" %)**RED , **(% style="color:green" %)**Green** flash once|(% style="width:202px" %)N/A 684 684 |(% style="width:157px" %)**Join request**|(% style="width:271px" %)(% style="color:green" %)**Green** (%%)led fast blink once (200ms)|(% style="width:202px" %)Yes 685 685 |(% style="width:157px" %)**Join Success**|(% style="width:271px" %)(% style="color:green" %)**Green**(%%) led on 5 second|(% style="width:202px" %)N/A ... ... @@ -710,8 +710,8 @@ 710 710 711 711 (% style="display:none" %) (%%) 712 712 713 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)714 -|=(% style="width: 100px; background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 205px;background-color:#D9E2F3;color:#0070C0" %)**Action**|=(% style="width: 205px;background-color:#D9E2F3;color:#0070C0" %)**Description**713 +(% border="1" style="background-color:#ffffcc; width:510px" %) 714 +|=(% style="width: 100px;" %)**Function**|=(% style="width: 205px;" %)**Action**|=(% style="width: 205px;" %)**Description** 715 715 |(% style="width:135px" %)Send Alarm|(% style="width:220px" %)Keep Pressing (% style="color:red" %)**RED**(%%) button for more than 5 seconds|(% style="width:265px" %)Enter Alarm Mode. See [[Alarm Mode>>||anchor="H2.8AlarmMode"]] 716 716 |(% style="width:135px" %)Exit Alarm Mode|(% style="width:220px" %)Fast press the (% style="color:red" %)**RED** (%%)button 10 times|(% style="width:265px" %)Exit Alarm Mode 717 717 |(% style="width:135px" %)Enter Deep Sleep Mode|(% style="width:220px" %)Press and hold the button for 10 seconds, then quickly press the device 3 times to enter deep sleep|(% style="width:265px" %)This is the mode ship out from factory. CPU will be complete in sleep mode and no LoRa activity, only use before deploy. ... ... @@ -718,6 +718,7 @@ 718 718 719 719 (% style="display:none" %) (%%) 720 720 721 + 721 721 == 2.13 USB Port Function == 722 722 723 723 ... ... @@ -730,6 +730,7 @@ 730 730 731 731 (% style="display:none" %) (%%) 732 732 734 + 733 733 == 2.14 Sleep Mode == 734 734 735 735 ... ... @@ -1078,14 +1078,12 @@ 1078 1078 AT+PT=41 ~-~-> set to detect walk motion. 1079 1079 1080 1080 1081 -(% style="color:blue" %)**Downlink Payload:0xB4** 1082 - 1083 +(% style="color:blue" %)**Downlink Payload:0xB4**(%%) 1083 1083 0xB4 14 ~/~/ Same as AT+PT=14 1084 1084 1085 1085 1086 -=== 3.2.17 Set AT command window time(Since firmware 1.4.5) === 1087 +=== **3.2.17 Set AT command window time(Since firmware 1.4.5)** === 1087 1087 1088 - 1089 1089 AT command window time setting, customers can set the required time according to their own operation mode.The unit is second. 1090 1090 1091 1091 (% style="color:blue" %)**AT Command:** ... ... @@ -1096,14 +1096,11 @@ 1096 1096 1097 1097 AT+ATST=15 ~-~-> Set the time to 15 seconds 1098 1098 1099 -(% style="color:blue" %)**Downlink Payload:0XB5** 1100 - 1099 +(% style="color:blue" %)**Downlink Payload:0XB5**(%%) 1101 1101 0xB5 0F ~/~/ Same as AT+ATST=15 1102 1102 1102 +=== **3.2.18 Set the stepmeter mode(Since firmware 1.4.5)** === 1103 1103 1104 -=== 3.2.18 Set the stepmeter mode(Since firmware 1.4.5) === 1105 - 1106 - 1107 1107 After setting the step counting mode, it cannot be interrupted by motion. This mode is very power consuming. Used on some special occasions. 1108 1108 1109 1109 (% style="color:blue" %)**AT Command:** ... ... @@ -1116,14 +1116,12 @@ 1116 1116 1117 1117 AT+PM=0 ~-~-> Turn OFF step counting mode 1118 1118 1119 -(% style="color:blue" %)**Downlink Payload:0XB6** 1120 - 1116 +(% style="color:blue" %)**Downlink Payload:0XB6**(%%) 1121 1121 0xB6 01 ~/~/ Same as AT+PM=1 1122 1122 1123 1123 1124 1124 === 3.2.19 Set down the decline detection mode(Since firmware 1.4.5) === 1125 1125 1126 - 1127 1127 This mode is used in conjunction with AT+PT(The recommended threshold is between 50 and 70, you need to set it according to the environment yourself). This function is used in hospitals, nursing homes, nursing homes and other places to prevent the elderly and patients from falling. No one knows. 1128 1128 1129 1129 (% style="color:blue" %)**AT Command:** ... ... @@ -1136,8 +1136,7 @@ 1136 1136 1137 1137 AT+FD=0 ~-~-> Turn OFF the Fall detection 1138 1138 1139 -(% style="color:blue" %)**Downlink Payload:0XB7** 1140 - 1134 +(% style="color:blue" %)**Downlink Payload:0XB7**(%%) 1141 1141 0xB7 01 ~/~/ Same as AT+FD=1 1142 1142 1143 1143 ... ... @@ -1653,6 +1653,7 @@ 1653 1653 1654 1654 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]. 1655 1655 1650 + 1656 1656 = 12. Reference = 1657 1657 1658 1658