Changes for page TrackerD -- LoRaWAN Tracker User Manual
Last modified by Xiaoling on 2025/04/14 16:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -678,8 +678,8 @@ 678 678 == 2.11 LED Status == 679 679 680 680 681 -(% border="1.5" style="background-color:#f 2f2f2; width:500px" %)682 -|=(% style="width: 150px; background-color:#D9E2F3;color:#0070C0" %)**Event**|=(% style="width: 200px;background-color:#D9E2F3;color:#0070C0" %)**Action**|=(% style="width: 150px;background-color:#D9E2F3;color:#0070C0" %)**AT+LON to control on/off**681 +(% border="1.5" style="background-color:#ffffcc; width:500px" %) 682 +|=(% style="width: 150px;" %)**Event**|=(% style="width: 200px;" %)**Action**|=(% style="width: 150px;" %)**AT+LON to control on/off** 683 683 |(% style="width:157px" %)**Power On**|(% style="width:271px" %)(% style="color:blue" %)**BLUE, **(% style="color:red" %)**RED , **(% style="color:green" %)**Green** flash once|(% style="width:202px" %)N/A 684 684 |(% style="width:157px" %)**Join request**|(% style="width:271px" %)(% style="color:green" %)**Green** (%%)led fast blink once (200ms)|(% style="width:202px" %)Yes 685 685 |(% style="width:157px" %)**Join Success**|(% style="width:271px" %)(% style="color:green" %)**Green**(%%) led on 5 second|(% style="width:202px" %)N/A ... ... @@ -710,8 +710,8 @@ 710 710 711 711 (% style="display:none" %) (%%) 712 712 713 -(% border="1" style="background-color:#f 2f2f2; width:510px" %)714 -|=(% style="width: 100px; background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 205px;background-color:#D9E2F3;color:#0070C0" %)**Action**|=(% style="width: 205px;background-color:#D9E2F3;color:#0070C0" %)**Description**713 +(% border="1" style="background-color:#ffffcc; width:510px" %) 714 +|=(% style="width: 100px;" %)**Function**|=(% style="width: 205px;" %)**Action**|=(% style="width: 205px;" %)**Description** 715 715 |(% style="width:135px" %)Send Alarm|(% style="width:220px" %)Keep Pressing (% style="color:red" %)**RED**(%%) button for more than 5 seconds|(% style="width:265px" %)Enter Alarm Mode. See [[Alarm Mode>>||anchor="H2.8AlarmMode"]] 716 716 |(% style="width:135px" %)Exit Alarm Mode|(% style="width:220px" %)Fast press the (% style="color:red" %)**RED** (%%)button 10 times|(% style="width:265px" %)Exit Alarm Mode 717 717 |(% style="width:135px" %)Enter Deep Sleep Mode|(% style="width:220px" %)Press and hold the button for 10 seconds, then quickly press the device 3 times to enter deep sleep|(% style="width:265px" %)This is the mode ship out from factory. CPU will be complete in sleep mode and no LoRa activity, only use before deploy. ... ... @@ -1081,13 +1081,11 @@ 1081 1081 1082 1082 1083 1083 (% style="color:blue" %)**Downlink Payload:0xB4**(%%) 1084 - 1085 1085 0xB4 14 ~/~/ Same as AT+PT=14 1086 1086 1087 1087 1088 -=== 3.2.17 Set AT command window time(Since firmware 1.4.5) === 1087 +=== **3.2.17 Set AT command window time(Since firmware 1.4.5)** === 1089 1089 1090 - 1091 1091 AT command window time setting, customers can set the required time according to their own operation mode.The unit is second. 1092 1092 1093 1093 (% style="color:blue" %)**AT Command:** ... ... @@ -1099,13 +1099,10 @@ 1099 1099 AT+ATST=15 ~-~-> Set the time to 15 seconds 1100 1100 1101 1101 (% style="color:blue" %)**Downlink Payload:0XB5**(%%) 1102 - 1103 1103 0xB5 0F ~/~/ Same as AT+ATST=15 1104 1104 1102 +=== **3.2.18 Set the stepmeter mode(Since firmware 1.4.5)** === 1105 1105 1106 -=== 3.2.18 Set the stepmeter mode(Since firmware 1.4.5) === 1107 - 1108 - 1109 1109 After setting the step counting mode, it cannot be interrupted by motion. This mode is very power consuming. Used on some special occasions. 1110 1110 1111 1111 (% style="color:blue" %)**AT Command:** ... ... @@ -1119,13 +1119,11 @@ 1119 1119 AT+PM=0 ~-~-> Turn OFF step counting mode 1120 1120 1121 1121 (% style="color:blue" %)**Downlink Payload:0XB6**(%%) 1122 - 1123 1123 0xB6 01 ~/~/ Same as AT+PM=1 1124 1124 1125 1125 1126 1126 === 3.2.19 Set down the decline detection mode(Since firmware 1.4.5) === 1127 1127 1128 - 1129 1129 This mode is used in conjunction with AT+PT(The recommended threshold is between 50 and 70, you need to set it according to the environment yourself). This function is used in hospitals, nursing homes, nursing homes and other places to prevent the elderly and patients from falling. No one knows. 1130 1130 1131 1131 (% style="color:blue" %)**AT Command:** ... ... @@ -1139,7 +1139,6 @@ 1139 1139 AT+FD=0 ~-~-> Turn OFF the Fall detection 1140 1140 1141 1141 (% style="color:blue" %)**Downlink Payload:0XB7**(%%) 1142 - 1143 1143 0xB7 01 ~/~/ Same as AT+FD=1 1144 1144 1145 1145 ... ... @@ -1337,7 +1337,7 @@ 1337 1337 1338 1338 1339 1339 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:314px" %) 1340 -|=(% style="width: 1 20px;background-color:#D9E2F3;color:#0070C0" %)**Pin**|=(% style="width: 69px;background-color:#D9E2F3;color:#0070C0" %)**Color**|=(% style="width: 125px;background-color:#D9E2F3;color:#0070C0" %)**USB Pin**1332 +|=(% style="width: 118px;background-color:#D9E2F3;color:#0070C0" %)**Pin**|=(% style="width: 67px;background-color:#D9E2F3;color:#0070C0" %)**Color**|=(% style="width: 123px;background-color:#D9E2F3;color:#0070C0" %)**USB Pin** 1341 1341 |(% style="width:118px" %)A4,B4,A9,B9|(% style="width:67px" %)Red|(% style="width:123px" %)VCC 1342 1342 |(% style="width:118px" %)A7,B7|(% style="width:67px" %)White|(% style="width:123px" %)D- (N/A) 1343 1343 |(% style="width:118px" %)A6,B6|(% style="width:67px" %)Green|(% style="width:123px" %)D+(N/A)