... ... @@ -1084,9 +1084,8 @@
1084 1084  0xB4 14          ~/~/  Same as AT+PT=14
1085 1085  
1086 1086  
1087 -=== 3.2.17  Set AT command window time(Since firmware 1.4.5) ===
1087 +=== **3.2.17  Set AT command window time(Since firmware 1.4.5)** ===
1088 1088  
1089 -
1090 1090  AT command window time setting, customers can set the required time according to their own operation mode.The unit is second.
1091 1091  
1092 1092  (% style="color:blue" %)**AT Command:**
... ... @@ -1098,12 +1098,10 @@
1098 1098   AT+ATST=15    ~-~-> Set the time to 15 seconds
1099 1099  
1100 1100  (% style="color:blue" %)**Downlink Payload:0XB5**(%%)
1101 -
1102 1102  0xB5 0F          ~/~/  Same as AT+ATST=15
1103 1103  
1104 -=== 3.2.18  Set the stepmeter mode(Since firmware 1.4.5) ===
1102 +=== **3.2.18  Set the stepmeter mode(Since firmware 1.4.5)** ===
1105 1105  
1106 -
1107 1107  After setting the step counting mode, it cannot be interrupted by motion. This mode is very power consuming. Used on some special occasions.
1108 1108  
1109 1109  (% style="color:blue" %)**AT Command:**
... ... @@ -1117,13 +1117,11 @@
1117 1117  AT+PM=0    ~-~->  Turn OFF step counting mode
1118 1118  
1119 1119  (% style="color:blue" %)**Downlink Payload:0XB6**(%%)
1120 -
1121 1121  0xB6 01          ~/~/  Same as AT+PM=1
1122 1122  
1123 1123  
1124 1124  === 3.2.19  Set down the decline detection mode(Since firmware 1.4.5) ===
1125 1125  
1126 -
1127 1127  This mode is used in conjunction with AT+PT(The recommended threshold is between 50 and 70, you need to set it according to the environment yourself). This function is used in hospitals, nursing homes, nursing homes and other places to prevent the elderly and patients from falling. No one knows.
1128 1128  
1129 1129  (% style="color:blue" %)**AT Command:**
... ... @@ -1137,7 +1137,6 @@
1137 1137  AT+FD=0    ~-~->  Turn OFF the Fall detection
1138 1138  
1139 1139  (% style="color:blue" %)**Downlink Payload:0XB7**(%%)
1140 -
1141 1141  0xB7 01          ~/~/  Same as AT+FD=1
1142 1142  
1143 1143  
... ... @@ -1334,8 +1334,8 @@
1334 1334  
1335 1335  
1336 1336  
1337 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:314px" %)
1338 -|=(% style="width: 120px;background-color:#D9E2F3;color:#0070C0" %)**Pin**|=(% style="width: 69px;background-color:#D9E2F3;color:#0070C0" %)**Color**|=(% style="width: 125px;background-color:#D9E2F3;color:#0070C0" %)**USB Pin**
1331 +(% border="1.5" cellspacing="3" style="background-color:#ffffcc; color:green; width:314px" %)
1332 +|=(% style="width: 118px;" %)**Pin**|=(% style="width: 67px;" %)**Color**|=(% style="width: 123px;" %)**USB Pin**
1339 1339  |(% style="width:118px" %)A4,B4,A9,B9|(% style="width:67px" %)Red|(% style="width:123px" %)VCC
1340 1340  |(% style="width:118px" %)A7,B7|(% style="width:67px" %)White|(% style="width:123px" %)D- (N/A)
1341 1341  |(% style="width:118px" %)A6,B6|(% style="width:67px" %)Green|(% style="width:123px" %)D+(N/A)
... ... @@ -1505,7 +1505,7 @@
1505 1505  
1506 1506  User might erase the entire flash include keys and default settings which cause this issue.
1507 1507  
1508 -After the upgrade is completed, enter (% style="color:blue" %)**AT+CFG**(%%) as shown in the figure below.
1502 +After the upgrade is completed, enter **AT+CFG** as shown in the figure below.
1509 1509  
1510 1510  
1511 1511  [[image:image-20221122100004-3.png||_mstalt="424242"]]