Changes for page TrackerD -- LoRaWAN Tracker User Manual
Last modified by Xiaoling on 2025/04/14 16:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -152,7 +152,7 @@ 152 152 Each TrackerD is shipped with a sticker with the default device EUI as below: 153 153 154 154 155 -[[image: 1664501677253-891.png||_mstalt="296569"]]155 +[[image:image-20230426085815-1.png]] 156 156 157 157 158 158 Input these keys to their LoRaWAN Server portal. Below is TTN V3 screen shot: ... ... @@ -1088,6 +1088,57 @@ 1088 1088 0xB4 14 ~/~/ Same as AT+PT=14 1089 1089 1090 1090 1091 +=== **3.2.17 Set AT command window time(Since firmware 1.4.5)** === 1092 + 1093 +AT command window time setting, customers can set the required time according to their own operation mode.The unit is second. 1094 + 1095 +(% style="color:blue" %)**AT Command:** 1096 + 1097 +(% style="color:#037691" %)**AT+ATST=XX** 1098 + 1099 + Example: 1100 + 1101 + AT+ATST=15 ~-~-> Set the time to 15 seconds 1102 + 1103 +(% style="color:blue" %)**Downlink Payload:0XB5**(%%) 1104 +0xB5 0F ~/~/ Same as AT+ATST=15 1105 + 1106 +=== **3.2.18 Set the stepmeter mode(Since firmware 1.4.5)** === 1107 + 1108 +After setting the step counting mode, it cannot be interrupted by motion. This mode is very power consuming. Used on some special occasions. 1109 + 1110 +(% style="color:blue" %)**AT Command:** 1111 + 1112 +(% style="color:#037691" %)**AT+PM=xx** 1113 + 1114 + Example: 1115 + 1116 + AT+PM=1 ~-~-> Turn on step counting mode 1117 + 1118 +AT+PM=0 ~-~-> Turn OFF step counting mode 1119 + 1120 +(% style="color:blue" %)**Downlink Payload:0XB6**(%%) 1121 +0xB6 01 ~/~/ Same as AT+PM=1 1122 + 1123 + 1124 +=== 3.2.19 Set down the decline detection mode(Since firmware 1.4.5) === 1125 + 1126 +This mode is used in conjunction with AT+PT(The recommended threshold is between 50 and 70, you need to set it according to the environment yourself). This function is used in hospitals, nursing homes, nursing homes and other places to prevent the elderly and patients from falling. No one knows. 1127 + 1128 +(% style="color:blue" %)**AT Command:** 1129 + 1130 +(% style="color:#037691" %)**AT+FD=xx** 1131 + 1132 + Example: 1133 + 1134 + AT+FD=1 ~-~-> Turn on the Fall detection 1135 + 1136 +AT+FD=0 ~-~-> Turn OFF the Fall detection 1137 + 1138 +(% style="color:blue" %)**Downlink Payload:0XB7**(%%) 1139 +0xB7 01 ~/~/ Same as AT+PM=1 1140 + 1141 + 1091 1091 = 4. Setting for Different Scenarios = 1092 1092 1093 1093
- image-20230426085815-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +190.0 KB - Content