Changes for page TrackerD -- LoRaWAN Tracker User Manual
Last modified by Xiaoling on 2025/04/14 16:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -152,7 +152,7 @@ 152 152 Each TrackerD is shipped with a sticker with the default device EUI as below: 153 153 154 154 155 -[[image: 1664501677253-891.png||_mstalt="296569"]]155 +[[image:image-20230426085815-1.png]] 156 156 157 157 158 158 Input these keys to their LoRaWAN Server portal. Below is TTN V3 screen shot: ... ... @@ -291,7 +291,9 @@ 291 291 |=(% scope="row" style="width: 75px;" %)**Size(bit)**|(% style="width:68px" %)5 Bits|(% style="width:87px" %)1 Bit|(% style="width:49px" %)1 Bit|(% style="width:126px" %)1 Bit 292 292 |=(% style="width: 75px;" %)**Value**|(% style="width:68px" %)Reserve|(% style="width:87px" %)[[PNACKMD>>||anchor="H2.4.4A0UplinkFPORT3D42CHistoryGNSSPositioning"]]|(% style="width:49px" %)[[LON>>||anchor="H3.2.5Disable2FEnableLEDflash"]]|(% style="width:126px" %)[[Transport Mode>>||anchor="H2.9TransportMode"]] 293 293 294 +(% style="display:none" %) 294 294 296 + 295 295 === 2.4.2 Uplink FPORT~=2, Realtime GNSS Positioning + Temperature & Humidity === 296 296 297 297 ... ... @@ -319,6 +319,9 @@ 319 319 |=(% scope="row" style="width: 50px;" %)**Size(bit)**|(% style="width:50px" %)1 bit|(% style="width:69px" %)1 bit|(% style="width:63px" %)14 bits 320 320 |=(% style="width: 72px;" %)**Value**|(% style="width:67px" %)reserve|(% style="width:69px" %)Alarm Indicate|(% style="width:63px" %)[[BAT>>||anchor="HBAT:"]] 321 321 324 +(% style="display:none" %) 325 + 326 + 322 322 ==== (% style="color:blue" %)**FLAG:**(%%) ==== 323 323 324 324 (% border="1.2" cellspacing="3" style="background-color:#ffffcc; color:green; width:183.222px" %) ... ... @@ -1083,6 +1083,57 @@ 1083 1083 0xB4 14 ~/~/ Same as AT+PT=14 1084 1084 1085 1085 1091 +=== **3.2.17 Set AT command window time(Since firmware 1.4.5)** === 1092 + 1093 +AT command window time setting, customers can set the required time according to their own operation mode.The unit is second. 1094 + 1095 +(% style="color:blue" %)**AT Command:** 1096 + 1097 +(% style="color:#037691" %)**AT+ATST=XX** 1098 + 1099 + Example: 1100 + 1101 + AT+ATST=15 ~-~-> Set the time to 15 seconds 1102 + 1103 +(% style="color:blue" %)**Downlink Payload:0XB5**(%%) 1104 +0xB5 0F ~/~/ Same as AT+ATST=15 1105 + 1106 +=== **3.2.18 Set the stepmeter mode(Since firmware 1.4.5)** === 1107 + 1108 +After setting the step counting mode, it cannot be interrupted by motion. This mode is very power consuming. Used on some special occasions. 1109 + 1110 +(% style="color:blue" %)**AT Command:** 1111 + 1112 +(% style="color:#037691" %)**AT+PM=xx** 1113 + 1114 + Example: 1115 + 1116 + AT+PM=1 ~-~-> Turn on step counting mode 1117 + 1118 +AT+PM=0 ~-~-> Turn OFF step counting mode 1119 + 1120 +(% style="color:blue" %)**Downlink Payload:0XB6**(%%) 1121 +0xB6 01 ~/~/ Same as AT+PM=1 1122 + 1123 + 1124 +=== 3.2.19 Set down the decline detection mode(Since firmware 1.4.5) === 1125 + 1126 +This mode is used in conjunction with AT+PT(The recommended threshold is between 50 and 70, you need to set it according to the environment yourself). This function is used in hospitals, nursing homes, nursing homes and other places to prevent the elderly and patients from falling. No one knows. 1127 + 1128 +(% style="color:blue" %)**AT Command:** 1129 + 1130 +(% style="color:#037691" %)**AT+FD=xx** 1131 + 1132 + Example: 1133 + 1134 + AT+FD=1 ~-~-> Turn on the Fall detection 1135 + 1136 +AT+FD=0 ~-~-> Turn OFF the Fall detection 1137 + 1138 +(% style="color:blue" %)**Downlink Payload:0XB7**(%%) 1139 +0xB7 01 ~/~/ Same as AT+PM=1 1140 + 1141 + 1086 1086 = 4. Setting for Different Scenarios = 1087 1087 1088 1088
- image-20230426085815-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +190.0 KB - Content