... ... @@ -93,7 +93,6 @@
93 93  * LoRa Transmit Mode: 125mA @ 20dBm 44mA @ 14dBm
94 94  * Tracking: max: 38mA
95 95  
96 -(% style="display:none" %)
97 97  
98 98  
99 99  == 1.3  Features ==
... ... @@ -114,7 +114,6 @@
114 114  * Tri-color LED, Alarm button
115 115  * Datalog
116 116  
117 -(% style="display:none" %)
118 118  
119 119  
120 120  == 1.4  Applications ==
... ... @@ -123,7 +123,6 @@
123 123  * Logistics and Supply Chain Management
124 124  * Human tracking
125 125  
126 -(% style="display:none" %)
127 127  
128 128  
129 129  = 2.  Use TrackerD =
... ... @@ -292,6 +292,7 @@
292 292  |=(% style="width: 75px;" %)**Value**|(% style="width:68px" %)Reserve|(% style="width:87px" %)[[PNACKMD>>||anchor="H2.4.4A0UplinkFPORT3D42CHistoryGNSSPositioning"]]|(% style="width:49px" %)[[LON>>||anchor="H3.2.5Disable2FEnableLEDflash"]]|(% style="width:126px" %)[[Transport Mode>>||anchor="H2.9TransportMode"]]
293 293  
294 294  
292 +
295 295  === 2.4.2 Uplink FPORT~=2, Realtime GNSS Positioning + Temperature & Humidity ===
296 296  
297 297  
... ... @@ -501,13 +501,13 @@
501 501  
502 502   [[image:image-20230302145315-1.png]]
503 503  
504 -**alarm**=(bytes[0] & 0x40)  ~/~/ Alarm status
502 +alarm=(bytes[0] & 0x40)  ~/~/ Alarm status
505 505  
506 -**batV**=~(~(~(bytes[0] & 0x3f) <<8) | bytes[1])/1000;  ~/~/ Battery,units:V
504 +batV=~(~(~(bytes[0] & 0x3f) <<8) | bytes[1])/1000;  ~/~/ Battery,units:V
507 507  
508 -**mod** = bytes[2] & 0xC0;
506 +mod = bytes[2] & 0xC0;
509 509  
510 -**Lon**=(bytes[2] & 0x20)
508 +Lon=(bytes[2] & 0x20)
511 511  
512 512  
513 513  === 2.4.7  Uplink FPORT~=8, WiFi Positioning with Strongest WiFi SSID(Since firmware 1.4.1) ===
... ... @@ -638,7 +638,7 @@
638 638  
639 639  
640 640  (((
641 -User can push the (% style="color:red" %)**RED button**(%%) by more than 5 seconds to enter Alarm Mode. Alarm Mode is used to send SOS info to IoT platform.
639 +User can push the (% style="color:red" %)**RED button**(%%) by more than 5 seconds to enter Alarm Mode.
642 642  )))
643 643  
644 644  
... ... @@ -664,8 +664,6 @@
664 664  
665 665  In Transport Mode, TrackerD will check if there is motion (threldhold defined by **[[PT)>>||anchor="H3.2.16GetorSetThresholdformotiondetectFF08Sincefirmware1.4.3FF09"]]** . If there is no motion, device will send uplinks every 20 minutes (Defined by **[[TDC)>>||anchor="H3.2.1SetTransmitInterval"]]** . If there is motion, device will send uplink every 5 minutes(defined by **[[MTDC)>>||anchor="H3.2.3SetTransportModePackettransmissioninterval"]]**.
666 666  
667 -When device is set in Transport Mode, it will uplink more frequenctly during moving.
668 -
669 669  * **[[MTDC>>||anchor="H3.2.3SetTransportModePackettransmissioninterval"]]** defines the Uplink Interval during transportation.
670 670  * **[[TDC>>||anchor="H3.2.1SetTransmitInterval"]]** defines the uplink interval when TrackerD is stactic.
671 671  * **[[PT>>||anchor="H3.2.16GetorSetThresholdformotiondetectFF08Sincefirmware1.4.3FF09"]]** defines the threldhold to detect a motion.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved