Changes for page TrackerD -- LoRaWAN Tracker User Manual
Last modified by Xiaoling on 2025/04/14 16:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -93,6 +93,7 @@ 93 93 * LoRa Transmit Mode: 125mA @ 20dBm 44mA @ 14dBm 94 94 * Tracking: max: 38mA 95 95 96 +(% style="display:none" %) 96 96 97 97 98 98 == 1.3 Features == ... ... @@ -113,6 +113,7 @@ 113 113 * Tri-color LED, Alarm button 114 114 * Datalog 115 115 117 +(% style="display:none" %) 116 116 117 117 118 118 == 1.4 Applications == ... ... @@ -121,6 +121,7 @@ 121 121 * Logistics and Supply Chain Management 122 122 * Human tracking 123 123 126 +(% style="display:none" %) 124 124 125 125 126 126 = 2. Use TrackerD = ... ... @@ -149,7 +149,7 @@ 149 149 Each TrackerD is shipped with a sticker with the default device EUI as below: 150 150 151 151 152 -[[image: 1664501677253-891.png||_mstalt="296569"]]155 +[[image:image-20230426085815-1.png]] 153 153 154 154 155 155 Input these keys to their LoRaWAN Server portal. Below is TTN V3 screen shot: ... ... @@ -288,6 +288,7 @@ 288 288 |=(% scope="row" style="width: 75px;" %)**Size(bit)**|(% style="width:68px" %)5 Bits|(% style="width:87px" %)1 Bit|(% style="width:49px" %)1 Bit|(% style="width:126px" %)1 Bit 289 289 |=(% style="width: 75px;" %)**Value**|(% style="width:68px" %)Reserve|(% style="width:87px" %)[[PNACKMD>>||anchor="H2.4.4A0UplinkFPORT3D42CHistoryGNSSPositioning"]]|(% style="width:49px" %)[[LON>>||anchor="H3.2.5Disable2FEnableLEDflash"]]|(% style="width:126px" %)[[Transport Mode>>||anchor="H2.9TransportMode"]] 290 290 294 +(% style="display:none" %) 291 291 292 292 293 293 === 2.4.2 Uplink FPORT~=2, Realtime GNSS Positioning + Temperature & Humidity === ... ... @@ -317,6 +317,9 @@ 317 317 |=(% scope="row" style="width: 50px;" %)**Size(bit)**|(% style="width:50px" %)1 bit|(% style="width:69px" %)1 bit|(% style="width:63px" %)14 bits 318 318 |=(% style="width: 72px;" %)**Value**|(% style="width:67px" %)reserve|(% style="width:69px" %)Alarm Indicate|(% style="width:63px" %)[[BAT>>||anchor="HBAT:"]] 319 319 324 +(% style="display:none" %) 325 + 326 + 320 320 ==== (% style="color:blue" %)**FLAG:**(%%) ==== 321 321 322 322 (% border="1.2" cellspacing="3" style="background-color:#ffffcc; color:green; width:183.222px" %) ... ... @@ -499,13 +499,13 @@ 499 499 500 500 [[image:image-20230302145315-1.png]] 501 501 502 -alarm=(bytes[0] & 0x40) ~/~/ Alarm status 509 +**alarm**=(bytes[0] & 0x40) ~/~/ Alarm status 503 503 504 -batV=~(~(~(bytes[0] & 0x3f) <<8) | bytes[1])/1000; ~/~/ Battery,units:V 511 +**batV**=~(~(~(bytes[0] & 0x3f) <<8) | bytes[1])/1000; ~/~/ Battery,units:V 505 505 506 -mod = bytes[2] & 0xC0; 513 +**mod** = bytes[2] & 0xC0; 507 507 508 -Lon=(bytes[2] & 0x20) 515 +**Lon**=(bytes[2] & 0x20) 509 509 510 510 511 511 === 2.4.7 Uplink FPORT~=8, WiFi Positioning with Strongest WiFi SSID(Since firmware 1.4.1) === ... ... @@ -636,7 +636,7 @@ 636 636 637 637 638 638 ((( 639 -User can push the (% style="color:red" %)**RED button**(%%) by more than 5 seconds to enter Alarm Mode. 646 +User can push the (% style="color:red" %)**RED button**(%%) by more than 5 seconds to enter Alarm Mode. Alarm Mode is used to send SOS info to IoT platform. 640 640 ))) 641 641 642 642 ... ... @@ -662,6 +662,8 @@ 662 662 663 663 In Transport Mode, TrackerD will check if there is motion (threldhold defined by **[[PT)>>||anchor="H3.2.16GetorSetThresholdformotiondetectFF08Sincefirmware1.4.3FF09"]]** . If there is no motion, device will send uplinks every 20 minutes (Defined by **[[TDC)>>||anchor="H3.2.1SetTransmitInterval"]]** . If there is motion, device will send uplink every 5 minutes(defined by **[[MTDC)>>||anchor="H3.2.3SetTransportModePackettransmissioninterval"]]**. 664 664 672 +When device is set in Transport Mode, it will uplink more frequenctly during moving. 673 + 665 665 * **[[MTDC>>||anchor="H3.2.3SetTransportModePackettransmissioninterval"]]** defines the Uplink Interval during transportation. 666 666 * **[[TDC>>||anchor="H3.2.1SetTransmitInterval"]]** defines the uplink interval when TrackerD is stactic. 667 667 * **[[PT>>||anchor="H3.2.16GetorSetThresholdformotiondetectFF08Sincefirmware1.4.3FF09"]]** defines the threldhold to detect a motion. ... ... @@ -1079,6 +1079,57 @@ 1079 1079 0xB4 14 ~/~/ Same as AT+PT=14 1080 1080 1081 1081 1091 +=== **3.2.17 Set AT command window time(Since firmware 1.4.5)** === 1092 + 1093 +AT command window time setting, customers can set the required time according to their own operation mode.The unit is second. 1094 + 1095 +(% style="color:blue" %)**AT Command:** 1096 + 1097 +(% style="color:#037691" %)**AT+ATST=XX** 1098 + 1099 + Example: 1100 + 1101 + AT+ATST=15 ~-~-> Set the time to 15 seconds 1102 + 1103 +(% style="color:blue" %)**Downlink Payload:0XB5**(%%) 1104 +0xB5 0F ~/~/ Same as AT+ATST=15 1105 + 1106 +=== **3.2.18 Set the stepmeter mode(Since firmware 1.4.5)** === 1107 + 1108 +After setting the step counting mode, it cannot be interrupted by motion. This mode is very power consuming. Used on some special occasions. 1109 + 1110 +(% style="color:blue" %)**AT Command:** 1111 + 1112 +(% style="color:#037691" %)**AT+PM=xx** 1113 + 1114 + Example: 1115 + 1116 + AT+PM=1 ~-~-> Turn on step counting mode 1117 + 1118 +AT+PM=0 ~-~-> Turn OFF step counting mode 1119 + 1120 +(% style="color:blue" %)**Downlink Payload:0XB6**(%%) 1121 +0xB6 01 ~/~/ Same as AT+PM=1 1122 + 1123 + 1124 +=== 3.2.19 Set down the decline detection mode(Since firmware 1.4.5) === 1125 + 1126 +This mode is used in conjunction with AT+PT(The recommended threshold is between 50 and 70, you need to set it according to the environment yourself). This function is used in hospitals, nursing homes, nursing homes and other places to prevent the elderly and patients from falling. No one knows. 1127 + 1128 +(% style="color:blue" %)**AT Command:** 1129 + 1130 +(% style="color:#037691" %)**AT+FD=xx** 1131 + 1132 + Example: 1133 + 1134 + AT+FD=1 ~-~-> Turn on the Fall detection 1135 + 1136 +AT+FD=0 ~-~-> Turn OFF the Fall detection 1137 + 1138 +(% style="color:blue" %)**Downlink Payload:0XB7**(%%) 1139 +0xB7 01 ~/~/ Same as AT+PM=1 1140 + 1141 + 1082 1082 = 4. Setting for Different Scenarios = 1083 1083 1084 1084
- image-20230426085815-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +190.0 KB - Content