Changes for page TrackerD -- LoRaWAN Tracker User Manual
Last modified by Xiaoling on 2025/04/27 16:48
From version 153.1
edited by Edwin Chen
on 2022/11/24 09:16
on 2022/11/24 09:16
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Xiaoling - Content
-
... ... @@ -421,7 +421,7 @@ 421 421 === 2.4.4 Uplink FPORT~=4, History GNSS Positioning === 422 422 423 423 424 -Set [[PNACKMD=1>>||anchor="H3.2.1 0A0A0AutoSendNone-ACKmessages"]], and TrackerD will wait for ACK for every uplink, when there is no LoRaWAN network, TrackerD will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.424 +Set [[PNACKMD=1>>||anchor="H3.2.11A0A0AutoSendNone-ACKmessages"]], and TrackerD will wait for ACK for every uplink, when there is no LoRaWAN network, TrackerD will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 425 425 426 426 427 427 (% style="color:red" %)**Note for this mode:** ... ... @@ -546,7 +546,7 @@ 546 546 547 547 total 273 entries,by default, 548 548 549 -User can set [[PNACKMD=1>>||anchor="H3.2.1 0A0A0AutoSendNone-ACKmessages"]], to enable Datalog feature.549 +User can set [[PNACKMD=1>>||anchor="H3.2.11A0A0AutoSendNone-ACKmessages"]], to enable Datalog feature. 550 550 551 551 Example use case. 552 552 ... ... @@ -590,7 +590,6 @@ 590 590 * **[[TDC>>||anchor="H3.2.1SetTransmitInterval"]]** defines the uplink interval when TrackerD is stactic. 591 591 * **[[PT>>||anchor="H3.2.16GetorSetThresholdformotiondetectFF08Sincefirmware1.4.3FF09"]]** defines the threldhold to detect a motion. 592 592 593 - 594 594 == 2.10 LED Status == 595 595 596 596 ... ... @@ -1231,15 +1231,19 @@ 1231 1231 1232 1232 == 8.3 Problem after Upgrading Firmware == 1233 1233 1234 -=== 8.3.1 Continue Restart after upgrading === 1233 +=== 8.3.1 "rst: (0x3 SW_RESET)" and Continue Restart after upgrading === 1235 1235 1235 +Error Output 1236 1236 1237 +[[image:image-20221122100004-4.png||_mstalt="424606"]] 1238 + 1237 1237 ((( 1238 -If it is V1.4.0 and the previous version, new partitions need to be loaded when upgrading. The new version of the software is stored in the partition package. The upgrade method is shown in the figure 1240 +Some partition is missed during upgrade, please upgrade below four files as example: 1241 + 1242 +[[image:image-20221122100004-2.png||_mstalt="423878" height="619" width="389"]] 1239 1239 ))) 1240 1240 1241 1241 1242 -[[image:image-20221118105249-3.png||_mstalt="430664"]] 1243 1243 1244 1244 1245 1245 === 8.3.2 TrackerD's led light is always GREEN on after upgrading === ... ... @@ -1297,12 +1297,6 @@ 1297 1297 1298 1298 1299 1299 1300 -=== 8.3.4 If there is a situation in Figure 1, and a new partition file needs to be added. Please refer to the operation steps in chapter 8.3.1 === 1301 - 1302 - 1303 -[[image:image-20221122100004-4.png||_mstalt="424606"]] 1304 - 1305 - 1306 1306 == 8.4 When positioning, it will restart or the PDOP setting is unsuccessful == 1307 1307 1308 1308