Changes for page TrackerD - LoRaWAN Tracker User Manual(Remove WiFi)
Last modified by Xiaoling on 2023/12/27 09:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -98,7 +98,6 @@ 98 98 * Tracking: max: 38mA 99 99 100 100 101 - 102 102 == 1.3 Features == 103 103 104 104 ... ... @@ -118,7 +118,6 @@ 118 118 * Datalog 119 119 120 120 121 - 122 122 == 1.4 Applications == 123 123 124 124 ... ... @@ -126,7 +126,6 @@ 126 126 * Human tracking 127 127 128 128 129 - 130 130 = 2.1 Use TrackerD = 131 131 132 132 ... ... @@ -357,12 +357,12 @@ 357 357 358 358 ==== (% style="color:blue" %)**Alarm:**(%%) ==== 359 359 360 -Example: 357 +**Example: ** 0x4B & 0x40 >> 6 = 0x01 361 361 362 362 363 363 ==== (% style="color:blue" %)**BAT:**(%%) ==== 364 364 365 -Example: 0CDD& 0x3FFF ⇒3293(mV).362 +**Example: ** 0x4B45 & 0x3FFF ⇒ 2885 (mV). 366 366 367 367 ((( 368 368 The battery info shows the battery voltage, User can use the below mapping to indicate the battery in percentage: \ ... ... @@ -378,26 +378,36 @@ 378 378 379 379 ==== (% style="color:blue" %)**MOD:**(%%) ==== 380 380 381 -Set the format of GPS data uplink link 378 +**Set the format of GPS data uplink link:** 382 382 383 -0x00: Enable uploading on-board Temperature and humidity values 380 +(% style="color:#037691" %)**0x00:** (%%) Enable uploading on-board Temperature and humidity values 381 +(% style="color:#037691" %)**0x01: ** (%%) Disable uploading on-board Temperature and humidity values 384 384 385 -0x01: Disable uploading on-board Temperature and humidity values 386 386 384 +**Set the format of BLE data uplink link:** 387 387 386 +(% style="color:#037691" %)**0x01: ** (%%) BLE Positioning with Strongest iBeacon 387 + 388 + 389 +**Example: ** (0x60>>6)& 0x3f =1. 390 + 391 + 392 + 388 388 ==== (% style="color:blue" %)**LON:**(%%) ==== 389 389 390 390 Enable/Disable LED activity for uplink 391 391 392 392 ((( 393 -0x00: Disable LED indicator. 398 +(% style="color:#037691" %)**0x00:** (%%) Disable LED indicator. 394 394 ))) 395 395 396 396 ((( 397 -0x01: Enable LED indicator (Default Value) 402 +(% style="color:#037691" %)**0x01:** (%%) Enable LED indicator (Default Value) 398 398 ))) 399 399 405 +**Example:** (0x60>>5) & 0x01=1. 400 400 407 + 401 401 ==== (% style="color:blue" %)**Hum:**(%%) ==== 402 402 403 403 0202 = //if (0x0202 & 0x8000 = 0 ): value =// 0x0202 / 100 = +514 ⇒ 51.4 degree ... ... @@ -482,7 +482,6 @@ 482 482 * (% style="color:#037691" %)**RSSI: ** (%%) The RSSI from the strongest iBeacon. 483 483 484 484 485 - 486 486 === 2.4.6 Add Payload format in TTN V3 === 487 487 488 488 ... ... @@ -636,7 +636,6 @@ 636 636 * [[Upgrade Firmware>>||anchor="H5.UploadFirmware"]] 637 637 638 638 639 - 640 640 = 3. Configure TrackerD via AT command or LoRaWAN downlink = 641 641 642 642 ... ... @@ -801,7 +801,6 @@ 801 801 802 802 * (% style="color:red" %)**1 : **(%%) (iBeacon)UUID+ Major + Minor+Power+Rssi+BAT+State 803 803 804 - 805 805 (% style="color:blue" %)**Example:** 806 806 807 807 AT+ SMOD =1,0 ,0 ~-~-> GPS+ BAT+ State+Tem&Hum ... ... @@ -865,7 +865,7 @@ 865 865 866 866 * (% style="color:blue" %)**AT Command:** 867 867 868 -(% style="color:#037691" %)**AT+CFM=xx .**872 +(% style="color:#037691" %)**AT+CFM=xx** 869 869 870 870 871 871 **~ Example:** ... ... @@ -881,6 +881,27 @@ 881 881 882 882 883 883 888 +=== 3.2.10 Auto Send None-ACK messages === 889 + 890 + 891 +TrackerD will wait for ACK for each uplink, If TrackerD doesn't get ACK from the IoT server, it will consider the message doesn't arrive server and store it. TrackerD keeps sending messages in normal periodically. Once TrackerD gets ACK from a server, it will consider the network is ok and start to send the not-arrive message. 892 + 893 + 894 +* (% style="color:blue" %)**AT Command: AT+PNACKMD** 895 + 896 +The default factory setting is 0. 897 + 898 + 899 +**Command Example Function Response:** 900 + 901 +(% style="color:#037691" %)**AT+PNACKMD=1** (%%) ~/~/ Poll None-ACK message OK 902 + 903 + 904 +* (% style="color:blue" %)**Downlink Command: 0x34** 905 + 906 +Example: 0x3401 ~/~/ Same as AT+PNACKMD=1 907 + 908 + 884 884 = 4. Setting for Different Scenarios = 885 885 886 886 ... ... @@ -1043,7 +1043,6 @@ 1043 1043 * (% style="color:red" %)**US915**(%%): Default frequency band US915 1044 1044 1045 1045 1046 - 1047 1047 = 9. Packing Info = 1048 1048 1049 1049 ... ... @@ -1058,7 +1058,6 @@ 1058 1058 * Weight: 50g 1059 1059 1060 1060 1061 - 1062 1062 = 10. Support = 1063 1063 1064 1064 ... ... @@ -1066,7 +1066,6 @@ 1066 1066 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]. 1067 1067 1068 1068 1069 - 1070 1070 = 11. Reference = 1071 1071 1072 1072