Last modified by Xiaoling on 2023/12/27 09:15

From version 74.4
edited by Xiaoling
on 2022/10/11 09:52
Change comment: There is no comment for this version
To version 74.7
edited by Xiaoling
on 2022/10/11 16:29
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -377,26 +377,30 @@
377 377  * < 3.39v:  0~~20%
378 378  
379 379  
380 -(% class="wikigeneratedid" %)
380 +
381 381  ==== (% style="color:blue" %)**MOD:**(%%) ====
382 382  
383 -Set the format of GPS data uplink link
383 +**Set the format of GPS data uplink link:**
384 384  
385 -0x00:  Enable uploading on-board Temperature and humidity values
385 +(% style="color:#037691" %)**0x00:** (%%) Enable uploading on-board Temperature and humidity values
386 +(% style="color:#037691" %)**0x01: ** (%%) Disable uploading on-board Temperature and humidity values
386 386  
387 -0x01:  Disable uploading on-board Temperature and humidity values
388 388  
389 +**Set the format of BLE data uplink link:**
389 389  
391 +(% style="color:#037691" %)**0x01: ** (%%) BLE Positioning with Strongest iBeacon
392 +
393 +
390 390  ==== (% style="color:blue" %)**LON:**(%%) ====
391 391  
392 392  Enable/Disable LED activity for uplink
393 393  
394 394  (((
395 -0x00:  Disable LED indicator.
399 +(% style="color:#037691" %)**0x00:**  (%%) Disable LED indicator.
396 396  )))
397 397  
398 398  (((
399 -0x01:  Enable LED indicator (Default Value)
403 +(% style="color:#037691" %)**0x01:**  (%%) Enable LED indicator (Default Value)
400 400  )))
401 401  
402 402  
... ... @@ -604,6 +604,7 @@
604 604  
605 605  
606 606  
611 +
607 607  == 2.11 Button Function ==
608 608  
609 609  
... ... @@ -627,6 +627,7 @@
627 627  
628 628  
629 629  
635 +
630 630  == 2.12 USB Port Function ==
631 631  
632 632  
... ... @@ -639,6 +639,7 @@
639 639  
640 640  
641 641  
648 +
642 642  = 3. Configure TrackerD via AT command or LoRaWAN downlink =
643 643  
644 644  
... ... @@ -786,37 +786,33 @@
786 786  
787 787  * (% style="color:blue" %)**AT Command:**
788 788  
789 -(% style="color:#037691" %)**AT+SMOD=aa,bb**
796 +(% style="color:#037691" %)**AT+SMOD=aa,bb,cc**
790 790  
791 791  (% style="color:#037691" %)** aa:**
792 792  
793 -* (% style="color:#037691" %)**1: GPS ONLY(Factory Settings):    **(%%)only get and uplink GPS location info.
794 -* (% style="color:#037691" %)**2: BLE ONLY:              **(%%)Only obtain iBeacon info via BLE and uplink. Design for Indoor tracking.
795 -* (% style="color:#037691" %)**3: GPS/BLE Hybrid:   **(%%)Combination for Indoor and Outdoor tracking.Devices will try to search BLE iBeacon first. If device can't find the iBeacon, it will use GPS for positioning
800 +* (% style="color:red" %)**1: GPS ONLY(Factory Settings):    **(%%)only get and uplink GPS location info.
801 +* (% style="color:red" %)**2: BLE ONLY:              **(%%)Only obtain iBeacon info via BLE and uplink. Design for Indoor tracking.
802 +* (% style="color:red" %)**3: GPS/BLE Hybrid:   **(%%)Combination for Indoor and Outdoor tracking.Devices will try to search BLE iBeacon first. If device can't find the iBeacon, it will use GPS for positioning.
796 796  
797 797  (% style="color:#037691" %)**bb:**
798 798  
799 -(% style="color:#037691" %)** if aa = 1: **
806 +* (% style="color:red" %)**0 :  **(%%)GPS+ BAT+ State+Tem&Hum
807 +* (% style="color:red" %)**1 :**(%%)  GPS +BAT State
800 800  
801 -* (% style="color:#037691" %)**0 :  **(%%)GPS+ BAT+ State+Tem&Hum
802 -* (% style="color:#037691" %)**1 :**(%%)  GPS +BAT State
809 +(% style="color:#037691" %)**cc:   **
803 803  
804 -(% style="color:#037691" %)** if aa = 2: **
811 +* (% style="color:red" %)**1 : **(%%) (iBeacon)UUID+ Major + Minor+Power+Rssi+BAT+State  
805 805  
806 -* (% style="color:#037691" %)**3 :  **(%%)(iBeacon)UUID+ Major + Minor+Power+Rssi+BAT+State
813 +(% style="color:blue" %)**Example:**
807 807  
808 - **Example:**
815 + AT+ SMOD =1,0 ,0 ~-~->  GPS+ BAT+ State+Tem&Hum
816 + AT+ SMOD =1,1,0 ~-~->  GPS +BAT State
817 + AT+ SMOD =2,0,1 ~-~->  (iBeacon)UUID+ Major + Minor+Power+Rssi+BAT+State
809 809  
810 - AT+ SMOD =1,0  **~-~-> ** GPS+ BAT+ State+Tem&Hum
811 811  
812 - AT+ SMOD =1,1    **~-~->**  GPS +BAT State
813 -
814 - AT+ SMOD =2,3    **~-~->**  (iBeacon)UUID+ Major + Minor+Power+Rssi+BAT+State
815 -
816 -
817 817  * (% style="color:blue" %)**Downlink Payload (prefix 0xA5):**
818 818  
819 -(% style="color:#037691" %)**0xA5 01 00**    (%%) ~/~/  Same as AT+ SMOD =1,0
822 +(% style="color:#037691" %)**0xA5 01 00 00**    (%%) ~/~/  Same as AT+ SMOD =1,0,0
820 820  
821 821  
822 822  
... ... @@ -833,7 +833,7 @@
833 833  
834 834  (% style="color:#037691" %)**AT+FTIME=xx**  (%%) **~-~-> ** Set to use xx as max fix time.
835 835  
836 -Example:  AT+FTIME=150
839 +**Example:**  AT+FTIME=150
837 837  
838 838  
839 839  * (% style="color:blue" %)**Downlink Payload (prefix 0xAA):**
... ... @@ -870,7 +870,7 @@
870 870  
871 871  * (% style="color:blue" %)**AT Command:**
872 872  
873 -(% style="color:#037691" %)**AT+CFM=xx. **
876 +(% style="color:#037691" %)**AT+CFM=xx**
874 874  
875 875  
876 876  **~ Example:**
... ... @@ -886,6 +886,27 @@
886 886  
887 887  
888 888  
892 +=== 3.2.10  Auto Send None-ACK messages ===
893 +
894 +
895 +TrackerD will wait for ACK for each uplink, If TrackerD doesn't get ACK from the IoT server, it will consider the message doesn't arrive server and store it. TrackerD keeps sending messages in normal periodically. Once TrackerD gets ACK from a server, it will consider the network is ok and start to send the not-arrive message.
896 +
897 +
898 +* (% style="color:blue" %)**AT Command: AT+PNACKMD**
899 +
900 +The default factory setting is 0.
901 +
902 +
903 +**Command Example Function Response:**
904 +
905 +(% style="color:#037691" %)**AT+PNACKMD=1**  (%%) ~/~/  Poll None-ACK message OK
906 +
907 +
908 +* (% style="color:blue" %)**Downlink Command: 0x34**
909 +
910 +Example: 0x3401  ~/~/  Same as AT+PNACKMD=1
911 +
912 +
889 889  = 4. Setting for Different Scenarios =
890 890  
891 891  
... ... @@ -1032,6 +1032,7 @@
1032 1032  
1033 1033  
1034 1034  
1059 +
1035 1035  = 8.  Order Info =
1036 1036  
1037 1037