Changes for page TrackerD - LoRaWAN Tracker User Manual(Remove WiFi)
Last modified by Xiaoling on 2023/12/27 09:15
From version 120.1
edited by Bei Jinggeng
on 2022/11/16 11:18
on 2022/11/16 11:18
Change comment:
Uploaded new attachment "image-20221116111844-4.png", version {1}
To version 136.1
edited by Edwin Chen
on 2022/11/21 22:26
on 2022/11/21 22:26
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bei1 +XWiki.Edwin - Content
-
... ... @@ -176,9 +176,13 @@ 176 176 177 177 178 178 179 -(% style="color:blue" %)**Step 2**:(%%) ower on TrackerD byusingtheonboardswitch.179 +(% style="color:blue" %)**Step 2**:(%%) Push this button will activate this device. 180 180 181 +(% id="cke_bm_7709S" style="display:none" %) [[image:1664502835802-546.png]] 181 181 183 +[[image:1664502835802-546.png]] 184 + 185 + 182 182 (% style="color:blue" %)**Step 3:**(%%) TrackerD will auto join to the LoRaWAN network. After join success, TrackerD will start to upload message to IoT server. 183 183 184 184 ... ... @@ -1034,16 +1034,16 @@ 1034 1034 1035 1035 boot_app0.bin @0e000 1036 1036 1037 - ESP_LORA-eeprom-class.bin @ 0x100001041 +US915.bin @ 0x10000(Select the bin file of the frequency band you need) 1038 1038 1039 1039 1040 -[[image:1 664503593459-435.png]]1044 +[[image:image-20221118105220-2.png]] 1041 1041 1042 1042 1043 1043 1044 1044 After upgrade finish, it will show finish as below: 1045 1045 1046 -[[image: 1664503611848-385.png]]1050 +[[image:image-20221118105402-4.png]] 1047 1047 1048 1048 1049 1049 ... ... @@ -1187,7 +1187,35 @@ 1187 1187 [[image:image-20221102140801-6.png]] 1188 1188 1189 1189 1194 +== 7.4 How to modify source code to compile different frequency band bin file? == 1190 1190 1196 + 1197 +(% class="box infomessage" %) 1198 +((( 1199 +(% style="color:red" %)**Important**(%%): Developer **MUST** follow the Arduino Environment Instruction exactly include change the SPI pin mappings. 1200 +See : [[**Set Up Arduino Compile Environment for TrackerD**. >>||anchor="H6.1.1SetupARDUINOcompileenvironment"]] 1201 +))) 1202 + 1203 +1.When compiling the frequency band, you need to find LMIC_PROJECT_CONFIG.H file. 1204 + 1205 +[[image:image-20221116111844-1.png||height="227" width="782"]] 1206 + 1207 +2.Open LMIC_PROJECT_CONFIG.H, find the corresponding macro definition and open it(AS923_2,AS923_3,AS923_4 except). 1208 + 1209 +[[image:image-20221116111844-2.png||height="262" width="781"]] 1210 + 1211 +3.Compile the AS923_JP band, please refer to the intention shown 1212 + 1213 +[[image:image-20221116111844-3.png||height="338" width="746"]] 1214 + 1215 +4.In other frequency bands in AS923, you need to find Lorabase_as923.H, path arduino-lmic \ src \ lmic, as shown in the figure below. 1216 + 1217 +[[image:image-20221116111844-4.png||height="641" width="739"]] 1218 + 1219 +[[image:image-20221116111844-5.png||height="551" width="708"]] 1220 + 1221 + 1222 + 1191 1191 = 8 Trouble Shooting = 1192 1192 1193 1193 ... ... @@ -1209,20 +1209,23 @@ 1209 1209 1210 1210 1211 1211 1212 -== 8.3 Thereason why it hasbeenrestarted afterupgrading(V.1.4.1)==1244 +== 8.3 Problem after Upgrading Firmware == 1213 1213 1246 +(% class="wikigeneratedid" %) 1247 +=== 8.3.1 Continue Restart after upgrading === 1214 1214 1249 + 1215 1215 ((( 1216 1216 If it is V1.4.0 and the previous version, new partitions need to be loaded when upgrading. The new version of the software is stored in the partition package. The upgrade method is shown in the figure 1217 1217 ))) 1218 1218 1219 1219 1220 -[[image:image-202211 07145243-1.png||height="695" width="443"]]1255 +[[image:image-20221118105249-3.png]] 1221 1221 1222 1222 1223 -== 8. 4If the device's led light is always onwhenupgrading(sincefirmware 1.4.1)==1258 +== 8.3.2 TrackerD's led light is always GREEN on after upgrading == 1224 1224 1225 -It is because the partitions are different when upgrading versions above 1.4.1, and a new partition file needs to be added. Please refer to the operation steps in chapter 8.3. 1260 +It is because the partitions are different when upgrading versions above 1.4.1, and a new partition file needs to be added. Please refer to the operation steps in chapter 8.3.1 1226 1226 1227 1227 1228 1228 ((( ... ... @@ -1231,6 +1231,12 @@ 1231 1231 1) Make Sure the device is in Open Area where can see the sky. 1232 1232 2) Set PDOP to a higher value. 1233 1233 1269 + AT+PDOP=2(can be positioned precisely.) 1270 + 1271 + AT+PDOP=7(Quickly locate in open spaces) 1272 + 1273 + AT+PDOP=14.7(Positioning can be acquired in complex environments) 1274 + 1234 1234 Please refer to this [[link>>http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/TrackerD/#H3.2.9SetPDOPvalueforGPSfixaccuracy]] on how to set up PDOP 1235 1235 ))) 1236 1236 ... ... @@ -1280,5 +1280,3 @@ 1280 1280 * [[**Firmware in Bin format**>>https://www.dropbox.com/sh/733s8xlwahhqg1d/AABxDz80lBVX_to8zNuUQWFja?dl=0]] 1281 1281 * **[[Source Code>>https://github.com/dragino/TrackerD]] ** 1282 1282 * [[**Hardware Source**>>https://www.dropbox.com/sh/orwoy6cecb89m4e/AAD37sRuUrvKsHgAJxuVTkB5a?dl=0]] 1283 - 1284 -
- image-20221116111844-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +78.0 KB - Content
- image-20221118104359-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +38.0 KB - Content
- image-20221118105220-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +40.2 KB - Content
- image-20221118105249-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +40.2 KB - Content
- image-20221118105402-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.7 KB - Content