Changes for page SN50v3-LB/LS -- LoRaWAN Sensor Node User Manual
Last modified by Bei Jinggeng on 2025/01/10 15:51
Change comment:
Uploaded new attachment "image-20231213102404-1.jpeg", version {1}
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -629,10 +629,18 @@ 629 629 630 630 [[image:image-20230818092200-1.png||height="344" width="627"]] 631 631 632 +===== 2.3.2.10.b Uplink, PWM output ===== 632 632 633 - =====2.3.2.10.b Downlink, PWM output=====634 +[[image:image-20230817172209-2.png||height="439" width="683"]] 634 634 635 635 637 + 638 + 639 + 640 + 641 +===== 2.3.2.10.c Downlink, PWM output ===== 642 + 643 + 636 636 [[image:image-20230817173800-3.png||height="412" width="685"]] 637 637 638 638 Downlink: (% style="color:#037691" %)**0B xx xx xx yy zz zz** ... ... @@ -893,13 +893,13 @@ 893 893 Since the device can only detect a pulse period of 50ms when [[AT+PWMSET=0>>||anchor="H3.3.8PWMsetting"]] (counting in microseconds), it is necessary to change the value of PWMSET according to the frequency of input capture. 894 894 ))) 895 895 * ((( 896 -PWM Input allows low power consumption. PWM Output to achieve real-time control, you need to go to Class C. Power consumption will not be low.904 +PWM Input allows low power consumption. PWM Output to achieve real-time control, you need to go to class C. Power consumption will not be low. 897 897 898 898 For PWM Output Feature, there are two consideration to see if the device can be powered by battery or have to be powered by external DC. 899 899 900 -a) If needs torealtime control output, SN50v3-LBhasbe run inCLass C andhaveto useexternal power source.908 +a) If real-time control output is required, the SN50v3-LB is already operating in class C and an external power supply must be used. 901 901 902 -b) If the output duration is more than 30 seconds, better tto use external power source.910 +b) If the output duration is more than 30 seconds, better to use external power source. 903 903 904 904 905 905 ... ... @@ -1153,25 +1153,26 @@ 1153 1153 * Example 1: Downlink Payload: 0A01 **~-~-->** AT+MOD=1 1154 1154 * Example 2: Downlink Payload: 0A04 **~-~-->** AT+MOD=4 1155 1155 1164 +(% id="H3.3.8PWMsetting" %) 1156 1156 === 3.3.8 PWM setting === 1157 1157 1158 1158 1159 -Feature: Set the time acquisition unit for PWM input capture. 1168 +(% class="mark" %)Feature: Set the time acquisition unit for PWM input capture. 1160 1160 1161 1161 (% style="color:blue" %)**AT Command: AT+PWMSET** 1162 1162 1163 1163 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 1164 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**1165 -|(% style="width:154px" %)AT+PWMSET=?|(% style="width: 196px" %)0|(% style="width:157px" %)(((1173 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Function**|=(% style="width: 130px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Response** 1174 +|(% style="width:154px" %)AT+PWMSET=?|(% style="width:223px" %)0|(% style="width:130px" %)((( 1166 1166 0(default) 1167 1167 1168 1168 OK 1169 1169 ))) 1170 -|(% style="width:154px" %)AT+PWMSET=0|(% style="width: 196px" %)The unit of PWM capture time is microsecond. The capture frequency range is between 20HZ and 100000HZ. |(% style="width:157px" %)(((1179 +|(% style="width:154px" %)AT+PWMSET=0|(% style="width:223px" %)The unit of PWM capture time is microsecond. The capture frequency range is between 20HZ and 100000HZ. |(% style="width:130px" %)((( 1171 1171 OK 1172 1172 1173 1173 ))) 1174 -|(% style="width:154px" %)AT+PWMSET=1|(% style="width: 196px" %)The unit of PWM capture time is millisecond. The capture frequency range is between 5HZ and 250HZ. |(% style="width:157px" %)OK1183 +|(% style="width:154px" %)AT+PWMSET=1|(% style="width:223px" %)The unit of PWM capture time is millisecond. The capture frequency range is between 5HZ and 250HZ. |(% style="width:130px" %)OK 1175 1175 1176 1176 (% style="color:blue" %)**Downlink Command: 0x0C** 1177 1177 ... ... @@ -1180,9 +1180,73 @@ 1180 1180 * Example 1: Downlink Payload: 0C00 **~-~-->** AT+PWMSET=0 1181 1181 * Example 2: Downlink Payload: 0C01 **~-~-->** AT+PWMSET=1 1182 1182 1183 -= 4. Battery & Power Consumption = 1184 1184 1185 1185 1194 +(% class="mark" %)Feature: Set the time acquisition unit for PWM output. 1195 + 1196 +(% style="color:blue" %)**AT Command: AT+PWMOUT** 1197 + 1198 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 1199 +|=(% style="width: 183px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Command Example**|=(% style="width: 193px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Function**|=(% style="width: 137px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Response** 1200 +|(% style="width:183px" %)AT+PWMOUT=?|(% style="width:193px" %)0|(% style="width:137px" %)((( 1201 +0,0,0(default) 1202 + 1203 +OK 1204 +))) 1205 +|(% style="width:183px" %)AT+PWMOUT=0,0,0|(% style="width:193px" %)The default is PWM input detection|(% style="width:137px" %)((( 1206 +OK 1207 + 1208 +))) 1209 +|(% style="width:183px" %)AT+PWMOUT=5,1000,50|(% style="width:193px" %)((( 1210 +The PWM output time is 5ms, the output frequency is 1000HZ, and the output duty cycle is 50%. 1211 + 1212 + 1213 +)))|(% style="width:137px" %)((( 1214 +OK 1215 +))) 1216 + 1217 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 1218 +|=(% style="width: 155px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Command Example**|=(% style="width: 112px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Function**|=(% style="width: 242px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**parameters** 1219 +|(% colspan="1" rowspan="3" style="width:155px" %)((( 1220 +AT+PWMOUT=a,b,c 1221 + 1222 + 1223 +)))|(% colspan="1" rowspan="3" style="width:112px" %)((( 1224 +Set PWM output time, output frequency and output duty cycle.((( 1225 + 1226 +))) 1227 + 1228 +((( 1229 + 1230 +))) 1231 +)))|(% style="width:242px" %)((( 1232 +a: Output time (unit: seconds) 1233 + 1234 +The value ranges from 0 to 65535. 1235 + 1236 +When a=65535, PWM will always output. 1237 +))) 1238 +|(% style="width:242px" %)((( 1239 +b: Output frequency (unit: HZ) 1240 +))) 1241 +|(% style="width:242px" %)((( 1242 +c: Output duty cycle (unit: %) 1243 + 1244 +The value ranges from 0 to 100. 1245 +))) 1246 + 1247 +(% style="color:blue" %)**Downlink Command: 0x0B01** 1248 + 1249 +Format: Command Code (0x0B01) followed by 6 bytes. 1250 + 1251 +Downlink payload:0B01 bb cc aa **~-~--> **AT+PWMOUT=a,b,c 1252 + 1253 +* Example 1: Downlink Payload: 0B01 03E8 0032 0005 **~-~-->** AT+PWMSET=5,1000,50 1254 +* Example 2: Downlink Payload: 0B01 07D0 003C 000A **~-~-->** AT+PWMSET=10,2000,60 1255 + 1256 += 4. Battery & Power Cons = 1257 + 1258 + 1186 1186 SN50v3-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 1187 1187 1188 1188 [[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
- image-20231213102404-1.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +4.2 MB - Content