... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Saxer
Content
... ... @@ -19,7 +19,7 @@
19 19  
20 20  (% style="color:blue" %)**SN50V3-LB **(%%)LoRaWAN Sensor Node is a Long Range LoRa Sensor Node. It is designed for outdoor use and powered by (% style="color:blue" %)** 8500mA Li/SOCl2 battery**(%%) for long term use.SN50V3-LB is designed to facilitate developers to quickly deploy industrial level LoRa and IoT solutions. It help users to turn the idea into a practical application and make the Internet of Things a reality. It is easy to program, create and connect your things everywhere.
21 21  
22 -(% style="color:blue" %)**SN50V3-LB wireless part**(%%) is based on SX1262 allows the user to send data and reach extremely long ranges at low data-rates.It provides ultra-long range spread spectrum communication and high interference immunity whilst minimising current consumption.It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, and so on.
22 +(% style="color:blue" %)**SN50V3-LB wireless part**(%%) is based on SX1262 allows the user to send data and reach extremely long ranges at low data-rates.It provides ultra-long range spread spectrum communication and high interference immunity whilst minimising current consumption.It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, smartphone detection, building automation, and so on.
23 23  
24 24  (% style="color:blue" %)**SN50V3-LB **(%%)has a powerful 48Mhz ARM microcontroller with 256KB flash and 64KB RAM. It has multiplex I/O pins to connect to different sensors.
25 25  
... ... @@ -27,6 +27,7 @@
27 27  
28 28  SN50V3-LB is the 3^^rd^^ generation of LSN50 series generic sensor node from Dragino. It is an (% style="color:blue" %)**open source project**(%%) and has a mature LoRaWAN stack and application software. User can use the pre-load software for their IoT projects or easily customize the software for different requirements.
29 29  
30 +
30 30  == 1.2 ​Features ==
31 31  
32 32  
... ... @@ -40,6 +40,7 @@
40 40  * Downlink to change configure
41 41  * 8500mAh Battery for long term use
42 42  
44 +
43 43  == 1.3 Specification ==
44 44  
45 45  
... ... @@ -77,6 +77,7 @@
77 77  * Sleep Mode: 5uA @ 3.3v
78 78  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
79 79  
82 +
80 80  == 1.4 Sleep mode and working mode ==
81 81  
82 82  
... ... @@ -104,6 +104,7 @@
104 104  )))
105 105  |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode.
106 106  
110 +
107 107  == 1.6 BLE connection ==
108 108  
109 109  
... ... @@ -580,15 +580,11 @@
580 580  
581 581  ==== 2.3.2.10  MOD~=10 (PWM input capture and output mode,Since firmware v1.2) ====
582 582  
583 -
584 584  In this mode, the uplink can perform PWM input capture, and the downlink can perform PWM output.
585 585  
586 -[[It should be noted when using PWM mode.>>||anchor="H2.3.3.12A0PWMMOD"]]
587 587  
588 -
589 589  ===== 2.3.2.10.a  Uplink, PWM input capture =====
590 590  
591 -
592 592  [[image:image-20230817172209-2.png||height="439" width="683"]]
593 593  
594 594  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:690px" %)
... ... @@ -610,28 +610,15 @@
610 610  [[image:image-20230817170702-1.png||height="161" width="1044"]]
611 611  
612 612  
613 -When the device detects the following PWM signal ,decoder will converts the pulse period and high-level duration to frequency and duty cycle.
613 +(% style="color:blue" %)**AT+PWMSET=AA(Default is 0)  ==> Corresponding downlink: 0B AA**
614 614  
615 -**Frequency:**
615 +When AA is 0, the unit of PWM capture time is microsecond. The capture frequency range is between 20HZ and 100000HZ. 
616 616  
617 -(% class="MsoNormal" %)
618 -(% lang="EN-US" %)If (% style="background-attachment:initial; background-clip:initial; background-image:initial; background-origin:initial; background-position:initial; background-repeat:initial; background-size:initial; color:blue; font-family:Arial,sans-serif" %)**AT+PWMSET**(%%)**=0, **(% lang="EN-US" %)Frequency= 1000000/(%%)Pulse period(HZ);
617 +When AA is 1, the unit of PWM capture time is millisecond.  The capture frequency range is between 5HZ and 250HZ. 
619 619  
620 -(% class="MsoNormal" %)
621 -(% lang="EN-US" %)If (% style="background-attachment:initial; background-clip:initial; background-image:initial; background-origin:initial; background-position:initial; background-repeat:initial; background-size:initial; color:blue; font-family:Arial,sans-serif" %)**AT+PWMSET**(%%)**=1, **(% lang="EN-US" %)Frequency= 1000/(%%)Pulse period(HZ);
622 622  
623 -
624 -(% class="MsoNormal" %)
625 -**Duty cycle:**
626 -
627 -Duty cycle= Duration of high level/ Pulse period*100 ~(%).
628 -
629 -[[image:image-20230818092200-1.png||height="344" width="627"]]
630 -
631 -
632 632  ===== 2.3.2.10.b  Downlink, PWM output =====
633 633  
634 -
635 635  [[image:image-20230817173800-3.png||height="412" width="685"]]
636 636  
637 637  Downlink:  (% style="color:#037691" %)**0B xx xx xx yy zz zz**
... ... @@ -876,25 +876,6 @@
876 876  ==== 2.3.3.12  PWM MOD ====
877 877  
878 878  
879 -* (((
880 -The maximum voltage that the SDA pin of SN50v3 can withstand is 3.6V, and it cannot exceed this voltage value, otherwise the chip may be burned.
881 -)))
882 -* (((
883 -If the PWM pin connected to the SDA pin cannot maintain a high level when it is not working, you need to remove the resistor R2 or replace it with a resistor with a larger resistance, otherwise a sleep current of about 360uA will be generated. The position of the resistor is shown in the figure below:
884 -)))
885 -
886 - [[image:image-20230817183249-3.png||height="320" width="417"]]
887 -
888 -* (((
889 -The signal captured by the input should preferably be processed by hardware filtering and then connected in. The software processing method is to capture four values, discard the first captured value, and then take the middle value of the second, third, and fourth captured values.
890 -)))
891 -* (((
892 -Since the device can only detect a pulse period of 50ms when [[AT+PWMSET=0>>||anchor="H3.3.8PWMsetting"]] (counting in microseconds), it is necessary to change the value of PWMSET according to the frequency of input capture.
893 -
894 -
895 -
896 -)))
897 -
898 898  ==== 2.3.3.13  Working MOD ====
899 899  
900 900  
... ... @@ -915,6 +915,7 @@
915 915  * 8: MOD9
916 916  * 9: MOD10
917 917  
886 +
918 918  == 2.4 Payload Decoder file ==
919 919  
920 920  
... ... @@ -944,6 +944,7 @@
944 944  * AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]].
945 945  * LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
946 946  
916 +
947 947  == 3.2 General Commands ==
948 948  
949 949  
... ... @@ -991,6 +991,7 @@
991 991  * Example 1: Downlink Payload: 0100001E  ~/~/  Set Transmit Interval (TDC) = 30 seconds
992 992  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
993 993  
964 +
994 994  === 3.3.2 Get Device Status ===
995 995  
996 996  
... ... @@ -1039,6 +1039,7 @@
1039 1039  * Example 3: Downlink Payload: 06000102  **~-~-->**  AT+INTMOD2=2
1040 1040  * Example 4: Downlink Payload: 06000201  **~-~-->**  AT+INTMOD3=1
1041 1041  
1013 +
1042 1042  === 3.3.4 Set Power Output Duration ===
1043 1043  
1044 1044  
... ... @@ -1071,6 +1071,7 @@
1071 1071  * Example 1: Downlink Payload: 070000  **~-~-->**  AT+5VT=0
1072 1072  * Example 2: Downlink Payload: 0701F4  **~-~-->**  AT+5VT=500
1073 1073  
1046 +
1074 1074  === 3.3.5 Set Weighing parameters ===
1075 1075  
1076 1076  
... ... @@ -1096,6 +1096,7 @@
1096 1096  * Example 2: Downlink Payload: 08020FA3  **~-~-->**  AT+WEIGAP=400.3
1097 1097  * Example 3: Downlink Payload: 08020FA0  **~-~-->**  AT+WEIGAP=400.0
1098 1098  
1072 +
1099 1099  === 3.3.6 Set Digital pulse count value ===
1100 1100  
1101 1101  
... ... @@ -1119,6 +1119,7 @@
1119 1119  * Example 1: Downlink Payload: 090100000000  **~-~-->**  AT+SETCNT=1,0
1120 1120  * Example 2: Downlink Payload: 0902000003E8  **~-~-->**  AT+SETCNT=2,1000
1121 1121  
1096 +
1122 1122  === 3.3.7 Set Workmode ===
1123 1123  
1124 1124  
... ... @@ -1143,33 +1143,7 @@
1143 1143  * Example 1: Downlink Payload: 0A01  **~-~-->**  AT+MOD=1
1144 1144  * Example 2: Downlink Payload: 0A04  **~-~-->**  AT+MOD=4
1145 1145  
1146 -=== 3.3.8 PWM setting ===
1147 1147  
1148 -
1149 -Feature: Set the time acquisition unit for PWM input capture.
1150 -
1151 -(% style="color:blue" %)**AT Command: AT+PWMSET**
1152 -
1153 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
1154 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1155 -|(% style="width:154px" %)AT+PWMSET=?|(% style="width:196px" %)0|(% style="width:157px" %)(((
1156 -0(default)
1157 -
1158 -OK
1159 -)))
1160 -|(% style="width:154px" %)AT+PWMSET=0|(% style="width:196px" %)The unit of PWM capture time is microsecond. The capture frequency range is between 20HZ and 100000HZ.   |(% style="width:157px" %)(((
1161 -OK
1162 -
1163 -)))
1164 -|(% style="width:154px" %)AT+PWMSET=1|(% style="width:196px" %)The unit of PWM capture time is millisecond.  The capture frequency range is between 5HZ and 250HZ. |(% style="width:157px" %)OK
1165 -
1166 -(% style="color:blue" %)**Downlink Command: 0x0C**
1167 -
1168 -Format: Command Code (0x0C) followed by 1 bytes.
1169 -
1170 -* Example 1: Downlink Payload: 0C00  **~-~-->**  AT+PWMSET=0
1171 -* Example 2: Downlink Payload: 0C01  **~-~-->**  AT+PWMSET=1
1172 -
1173 1173  = 4. Battery & Power Consumption =
1174 1174  
1175 1175  
... ... @@ -1195,6 +1195,7 @@
1195 1195  * (Recommanded way) OTA firmware update via wireless: **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]**
1196 1196  * Update through UART TTL interface: **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
1197 1197  
1147 +
1198 1198  = 6. FAQ =
1199 1199  
1200 1200  == 6.1 Where can i find source code of SN50v3-LB? ==
... ... @@ -1203,6 +1203,7 @@
1203 1203  * **[[Hardware Source Files>>https://github.com/dragino/Lora/tree/master/LSN50/v3.0]].**
1204 1204  * **[[Software Source Code & Compile instruction>>https://github.com/dragino/SN50v3]].**
1205 1205  
1156 +
1206 1206  == 6.2 How to generate PWM Output in SN50v3-LB? ==
1207 1207  
1208 1208  
... ... @@ -1242,6 +1242,7 @@
1242 1242  * (% style="color:red" %)**20**(%%): With M20 waterproof cable hole
1243 1243  * (% style="color:red" %)**NH**(%%): No Hole
1244 1244  
1196 +
1245 1245  = 8. ​Packing Info =
1246 1246  
1247 1247  
... ... @@ -1256,6 +1256,7 @@
1256 1256  * Package Size / pcs : cm
1257 1257  * Weight / pcs : g
1258 1258  
1211 +
1259 1259  = 9. Support =
1260 1260  
1261 1261  
image-20230817183218-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -137.1 KB
Content
image-20230817183249-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -948.6 KB
Content
image-20230818092200-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -98.9 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0