... ... @@ -41,6 +41,8 @@
41 41  * Downlink to change configure
42 42  * 8500mAh Battery for long term use
43 43  
44 +
45 +
44 44  == 1.3 Specification ==
45 45  
46 46  
... ... @@ -78,6 +78,8 @@
78 78  * Sleep Mode: 5uA @ 3.3v
79 79  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
80 80  
83 +
84 +
81 81  == 1.4 Sleep mode and working mode ==
82 82  
83 83  
... ... @@ -105,6 +105,8 @@
105 105  )))
106 106  |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode.
107 107  
112 +
113 +
108 108  == 1.6 BLE connection ==
109 109  
110 110  
... ... @@ -123,7 +123,7 @@
123 123  == 1.7 Pin Definitions ==
124 124  
125 125  
126 -[[image:image-20230610163213-1.png||height="404" width="699"]]
132 +[[image:image-20230513102034-2.png]]
127 127  
128 128  
129 129  == 1.8 Mechanical ==
... ... @@ -136,7 +136,7 @@
136 136  [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]]
137 137  
138 138  
139 -== 1.9 Hole Option ==
145 +== Hole Option ==
140 140  
141 141  
142 142  SN50v3-LB has different hole size options for different size sensor cable. The options provided are M12, M16 and M20. The definition is as below:
... ... @@ -151,7 +151,7 @@
151 151  == 2.1 How it works ==
152 152  
153 153  
154 -The SN50v3-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the SN50v3-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
160 +The SN50v3-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the S31x-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
155 155  
156 156  
157 157  == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
... ... @@ -159,7 +159,7 @@
159 159  
160 160  Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LPS8v2>>url:https://www.dragino.com/products/lora-lorawan-gateway/item/228-lps8v2.html]] as a LoRaWAN gateway in this example.
161 161  
162 -The LPS8v2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
168 +The LPS8V2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
163 163  
164 164  
165 165  (% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from SN50v3-LB.
... ... @@ -208,7 +208,7 @@
208 208  === 2.3.1 Device Status, FPORT~=5 ===
209 209  
210 210  
211 -Users can use the downlink command(**0x26 01**) to ask SN50v3-LB to send device configure detail, include device configure status. SN50v3-LB will uplink a payload via FPort=5 to server.
217 +Users can use the downlink command(**0x26 01**) to ask SN50v3 to send device configure detail, include device configure status. SN50v3 will uplink a payload via FPort=5 to server.
212 212  
213 213  The Payload format is as below.
214 214  
... ... @@ -216,44 +216,44 @@
216 216  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
217 217  |(% colspan="6" style="background-color:#d9e2f3; color:#0070c0" %)**Device Status (FPORT=5)**
218 218  |(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|(% style="width:91px" %)**1**|(% style="width:86px" %)**1**|(% style="width:44px" %)**2**
219 -|(% style="width:103px" %)Value|(% style="width:72px" %)Sensor Model|Firmware Version|(% style="width:91px" %)Frequency Band|(% style="width:86px" %)Sub-band|(% style="width:44px" %)BAT
225 +|(% style="width:103px" %)**Value**|(% style="width:72px" %)Sensor Model|Firmware Version|(% style="width:91px" %)Frequency Band|(% style="width:86px" %)Sub-band|(% style="width:44px" %)BAT
220 220  
221 221  Example parse in TTNv3
222 222  
223 223  
224 -(% style="color:#037691" %)**Sensor Model**(%%): For SN50v3-LB, this value is 0x1C
230 +(% style="color:#037691" %)**Sensor Model**(%%): For SN50v3, this value is 0x1C
225 225  
226 226  (% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version
227 227  
228 228  (% style="color:#037691" %)**Frequency Band**:
229 229  
230 -0x01: EU868
236 +*0x01: EU868
231 231  
232 -0x02: US915
238 +*0x02: US915
233 233  
234 -0x03: IN865
240 +*0x03: IN865
235 235  
236 -0x04: AU915
242 +*0x04: AU915
237 237  
238 -0x05: KZ865
244 +*0x05: KZ865
239 239  
240 -0x06: RU864
246 +*0x06: RU864
241 241  
242 -0x07: AS923
248 +*0x07: AS923
243 243  
244 -0x08: AS923-1
250 +*0x08: AS923-1
245 245  
246 -0x09: AS923-2
252 +*0x09: AS923-2
247 247  
248 -0x0a: AS923-3
254 +*0x0a: AS923-3
249 249  
250 -0x0b: CN470
256 +*0x0b: CN470
251 251  
252 -0x0c: EU433
258 +*0x0c: EU433
253 253  
254 -0x0d: KR920
260 +*0x0d: KR920
255 255  
256 -0x0e: MA869
262 +*0x0e: MA869
257 257  
258 258  
259 259  (% style="color:#037691" %)**Sub-Band**:
... ... @@ -277,22 +277,21 @@
277 277  === 2.3.2 Working Modes & Sensor Data. Uplink via FPORT~=2 ===
278 278  
279 279  
280 -SN50v3-LB has different working mode for the connections of different type of sensors. This section describes these modes. Use can use the AT Command (% style="color:blue" %)**AT+MOD**(%%) to set SN50v3-LB to different working modes.
286 +SN50v3 has different working mode for the connections of different type of sensors. This section describes these modes. Use can use the AT Command AT+MOD to set SN50v3 to different working modes.
281 281  
282 282  For example:
283 283  
284 - (% style="color:blue" %)**AT+MOD=2  ** (%%) ~/~/ will set the SN50v3 to work in MOD=2 distance mode which target to measure distance via Ultrasonic Sensor.
290 + **AT+MOD=2  ** ~/~/ will set the SN50v3 to work in MOD=2 distance mode which target to measure distance via Ultrasonic Sensor.
285 285  
286 286  
287 287  (% style="color:red" %) **Important Notice:**
288 288  
289 -~1. Some working modes has payload more than 12 bytes, The US915/AU915/AS923 frequency bands' definition has maximum 11 bytes in (% style="color:blue" %)**DR0**(%%). Server sides will see NULL payload while SN50v3-LB transmit in DR0 with 12 bytes payload.
295 +1. Some working modes has payload more than 12 bytes, The US915/AU915/AS923 frequency bands' definition has maximum 11 bytes in **DR0**. Server sides will see NULL payload while SN50v3 transmit in DR0 with 12 bytes payload.
296 +1. All modes share the same Payload Explanation from HERE.
297 +1. By default, the device will send an uplink message every 20 minutes.
290 290  
291 -2. All modes share the same Payload Explanation from HERE.
292 292  
293 -3. By default, the device will send an uplink message every 20 minutes.
294 294  
295 -
296 296  ==== 2.3.2.1  MOD~=1 (Default Mode) ====
297 297  
298 298  
... ... @@ -300,7 +300,7 @@
300 300  
301 301  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
302 302  |(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:20px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:100px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:90px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:130px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:80px" %)**2**
303 -|Value|Bat|(% style="width:191px" %)(((
308 +|**Value**|Bat|(% style="width:191px" %)(((
304 304  Temperature(DS18B20)(PC13)
305 305  )))|(% style="width:78px" %)(((
306 306  ADC(PA4)
... ... @@ -315,6 +315,7 @@
315 315  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220627150949-6.png?rev=1.1||alt="image-20220627150949-6.png"]]
316 316  
317 317  
323 +
318 318  ==== 2.3.2.2  MOD~=2 (Distance Mode) ====
319 319  
320 320  
... ... @@ -322,7 +322,7 @@
322 322  
323 323  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
324 324  |(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:30px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:110px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:40px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:110px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:140px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:40px" %)**2**
325 -|Value|BAT|(% style="width:196px" %)(((
331 +|**Value**|BAT|(% style="width:196px" %)(((
326 326  Temperature(DS18B20)(PC13)
327 327  )))|(% style="width:87px" %)(((
328 328  ADC(PA4)
... ... @@ -329,8 +329,9 @@
329 329  )))|(% style="width:189px" %)(((
330 330  Digital in(PB15) & Digital Interrupt(PA8)
331 331  )))|(% style="width:208px" %)(((
332 -Distance measure by: 1) LIDAR-Lite V3HP
333 -Or 2) Ultrasonic Sensor
338 +Distance measure by:1) LIDAR-Lite V3HP
339 +Or
340 +2) Ultrasonic Sensor
334 334  )))|(% style="width:117px" %)Reserved
335 335  
336 336  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/1656324539647-568.png?rev=1.1||alt="1656324539647-568.png"]]
... ... @@ -343,7 +343,7 @@
343 343  
344 344  (% style="color:blue" %)**Connection to Ultrasonic Sensor:**
345 345  
346 -(% style="color:red" %)**Need to remove R1 and R2 resistors to get low power,otherwise there will be 240uA standby current.**
353 +Need to remove R1 and R2 resistors to get low power,otherwise there will be 240uA standby current.
347 347  
348 348  [[image:image-20230512173903-6.png||height="596" width="715"]]
349 349  
... ... @@ -352,7 +352,7 @@
352 352  
353 353  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
354 354  |(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:20px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:100px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:100px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:120px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:80px" %)**2**
355 -|Value|BAT|(% style="width:183px" %)(((
362 +|**Value**|BAT|(% style="width:183px" %)(((
356 356  Temperature(DS18B20)(PC13)
357 357  )))|(% style="width:173px" %)(((
358 358  Digital in(PB15) & Digital Interrupt(PA8)
... ... @@ -360,7 +360,8 @@
360 360  ADC(PA4)
361 361  )))|(% style="width:323px" %)(((
362 362  Distance measure by:1)TF-Mini plus LiDAR
363 -Or 2) TF-Luna LiDAR
370 +Or 
371 +2) TF-Luna LiDAR
364 364  )))|(% style="width:188px" %)Distance signal  strength
365 365  
366 366  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/1656376779088-686.png?rev=1.1||alt="1656376779088-686.png"]]
... ... @@ -368,7 +368,7 @@
368 368  
369 369  **Connection to [[TF-Mini plus>>url:http://en.benewake.com/product/detail/5c345cd0e5b3a844c472329b.html]] LiDAR(UART version):**
370 370  
371 -(% style="color:red" %)**Need to remove R3 and R4 resistors to get low power,otherwise there will be 400uA standby current.**
379 +Need to remove R3 and R4 resistors to get low power,otherwise there will be 400uA standby current.
372 372  
373 373  [[image:image-20230512180609-7.png||height="555" width="802"]]
374 374  
... ... @@ -375,9 +375,9 @@
375 375  
376 376  **Connection to [[TF-Luna>>url:http://en.benewake.com/product/detail/5e1c1fd04d839408076b6255.html]] LiDAR (UART version):**
377 377  
378 -(% style="color:red" %)**Need to remove R3 and R4 resistors to get low power,otherwise there will be 400uA standby current.**
386 +Need to remove R3 and R4 resistors to get low power,otherwise there will be 400uA standby current.
379 379  
380 -[[image:image-20230610170047-1.png||height="452" width="799"]]
388 +[[image:image-20230513105207-4.png||height="469" width="802"]]
381 381  
382 382  
383 383  ==== 2.3.2.3  MOD~=3 (3 ADC + I2C) ====
... ... @@ -389,7 +389,7 @@
389 389  |=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)(((
390 390  **Size(bytes)**
391 391  )))|=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 90px;background-color:#D9E2F3;color:#0070C0" %)**1**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)2|=(% style="width: 100px;background-color:#D9E2F3;color:#0070C0" %)2|=(% style="width: 20px;background-color:#D9E2F3;color:#0070C0" %)1
392 -|Value|(% style="width:68px" %)(((
400 +|**Value**|(% style="width:68px" %)(((
393 393  ADC1(PA4)
394 394  )))|(% style="width:75px" %)(((
395 395  ADC2(PA5)
... ... @@ -413,7 +413,7 @@
413 413  
414 414  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
415 415  |(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:20px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:100px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:100px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:100px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:100px" %)**2**
416 -|Value|BAT|(% style="width:186px" %)(((
424 +|**Value**|BAT|(% style="width:186px" %)(((
417 417  Temperature1(DS18B20)(PC13)
418 418  )))|(% style="width:82px" %)(((
419 419  ADC(PA4)
... ... @@ -424,10 +424,10 @@
424 424  
425 425  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/1656377606181-607.png?rev=1.1||alt="1656377606181-607.png"]]
426 426  
427 -
428 428  [[image:image-20230513134006-1.png||height="559" width="736"]]
429 429  
430 430  
438 +
431 431  ==== 2.3.2.5  MOD~=5(Weight Measurement by HX711) ====
432 432  
433 433  
... ... @@ -435,8 +435,8 @@
435 435  
436 436  Each HX711 need to be calibrated before used. User need to do below two steps:
437 437  
438 -1. Zero calibration. Don't put anything on load cell and run (% style="color:blue" %)**AT+WEIGRE**(%%) to calibrate to Zero gram.
439 -1. Adjust calibration factor (default value 400): Put a known weight thing on load cell and run (% style="color:blue" %)**AT+WEIGAP**(%%) to adjust the Calibration Factor.
446 +1. Zero calibration. Don't put anything on load cell and run **AT+WEIGRE** to calibrate to Zero gram.
447 +1. Adjust calibration factor (default value 400): Put a known weight thing on load cell and run **AT+WEIGAP** to adjust the Calibration Factor.
440 440  1. (((
441 441  Weight has 4 bytes, the unit is g.
442 442  
... ... @@ -446,7 +446,7 @@
446 446  
447 447  For example:
448 448  
449 -(% style="color:blue" %)**AT+GETSENSORVALUE =0**
457 +**AT+GETSENSORVALUE =0**
450 450  
451 451  Response:  Weight is 401 g
452 452  
... ... @@ -456,7 +456,7 @@
456 456  |=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)(((
457 457  **Size(bytes)**
458 458  )))|=(% style="width: 20px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 150px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 200px;background-color:#D9E2F3;color:#0070C0" %)**1**|=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)**4**
459 -|Value|BAT|(% style="width:193px" %)(((
467 +|**Value**|BAT|(% style="width:193px" %)(((
460 460  Temperature(DS18B20)(PC13)
461 461  )))|(% style="width:85px" %)(((
462 462  ADC(PA4)
... ... @@ -467,6 +467,7 @@
467 467  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220820120036-2.png?width=1003&height=469&rev=1.1||alt="image-20220820120036-2.png" height="469" width="1003"]]
468 468  
469 469  
478 +
470 470  ==== 2.3.2.6  MOD~=6 (Counting Mode) ====
471 471  
472 472  
... ... @@ -481,7 +481,7 @@
481 481  
482 482  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
483 483  |=(% style="width: 60px;background-color:#D9E2F3;color:#0070C0" %)**Size(bytes)**|=(% style="width: 40px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 180px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 60px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 100px;background-color:#D9E2F3;color:#0070C0" %)**1**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**4**
484 -|Value|BAT|(% style="width:256px" %)(((
493 +|**Value**|BAT|(% style="width:256px" %)(((
485 485  Temperature(DS18B20)(PC13)
486 486  )))|(% style="width:108px" %)(((
487 487  ADC(PA4)
... ... @@ -494,6 +494,7 @@
494 494  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/1656378441509-171.png?rev=1.1||alt="1656378441509-171.png"]]
495 495  
496 496  
506 +
497 497  ==== 2.3.2.7  MOD~=7 (Three interrupt contact modes) ====
498 498  
499 499  
... ... @@ -501,7 +501,7 @@
501 501  |=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)(((
502 502  **Size(bytes)**
503 503  )))|=(% style="width: 20px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 90px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 90px;background-color:#D9E2F3;color:#0070C0" %)**1**|=(% style="width: 90px;background-color:#D9E2F3;color:#0070C0" %)**1**|=(% style="width: 90px;background-color:#D9E2F3;color:#0070C0" %)1|=(% style="width: 40px;background-color:#D9E2F3;color:#0070C0" %)2
504 -|Value|BAT|(% style="width:188px" %)(((
514 +|**Value**|BAT|(% style="width:188px" %)(((
505 505  Temperature(DS18B20)
506 506  (PC13)
507 507  )))|(% style="width:83px" %)(((
... ... @@ -520,7 +520,7 @@
520 520  |=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)(((
521 521  **Size(bytes)**
522 522  )))|=(% style="width: 30px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 70px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 120px;background-color:#D9E2F3;color:#0070C0" %)**1**|=(% style="width: 70px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 70px;background-color:#D9E2F3;color:#0070C0" %)2
523 -|Value|BAT|(% style="width:207px" %)(((
533 +|**Value**|BAT|(% style="width:207px" %)(((
524 524  Temperature(DS18B20)
525 525  (PC13)
526 526  )))|(% style="width:94px" %)(((
... ... @@ -543,18 +543,18 @@
543 543  |=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)(((
544 544  **Size(bytes)**
545 545  )))|=(% style="width: 20px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 90px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 90px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 60px;background-color:#D9E2F3;color:#0070C0" %)**1**|=(% style="width: 90px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 60px;background-color:#D9E2F3;color:#0070C0" %)4|=(% style="width: 60px;background-color:#D9E2F3;color:#0070C0" %)4
546 -|Value|BAT|(((
547 -Temperature
548 -(DS18B20)(PC13)
556 +|**Value**|BAT|(((
557 +Temperature1(DS18B20)
558 +(PC13)
549 549  )))|(((
550 -Temperature2
551 -(DS18B20)(PB9)
560 +Temperature2(DS18B20)
561 +(PB9)
552 552  )))|(((
553 553  Digital Interrupt
554 554  (PB15)
555 555  )))|(% style="width:193px" %)(((
556 -Temperature3
557 -(DS18B20)(PB8)
566 +Temperature3(DS18B20)
567 +(PB8)
558 558  )))|(% style="width:78px" %)(((
559 559  Count1(PA8)
560 560  )))|(% style="width:78px" %)(((
... ... @@ -579,78 +579,6 @@
579 579  When AA is 2, set the count of PA4 pin to BB Corresponding downlink:09 02 bb bb bb bb
580 580  
581 581  
582 -==== 2.3.2.10  MOD~=10 (PWM input capture and output mode,Since firmware v1.2) ====
583 -
584 -
585 -In this mode, the uplink can perform PWM input capture, and the downlink can perform PWM output.
586 -
587 -[[It should be noted when using PWM mode.>>||anchor="H2.3.3.12A0PWMMOD"]]
588 -
589 -
590 -===== 2.3.2.10.a  Uplink, PWM input capture =====
591 -
592 -
593 -[[image:image-20230817172209-2.png||height="439" width="683"]]
594 -
595 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:690px" %)
596 -|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:20px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:100px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:135px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:89px" %)**2**
597 -|Value|Bat|(% style="width:191px" %)(((
598 -Temperature(DS18B20)(PC13)
599 -)))|(% style="width:78px" %)(((
600 -ADC(PA4)
601 -)))|(% style="width:135px" %)(((
602 -PWM_Setting
603 -
604 -&Digital Interrupt(PA8)
605 -)))|(% style="width:70px" %)(((
606 -Pulse period
607 -)))|(% style="width:89px" %)(((
608 -Duration of high level
609 -)))
610 -
611 -[[image:image-20230817170702-1.png||height="161" width="1044"]]
612 -
613 -
614 -When the device detects the following PWM signal ,decoder will converts the pulse period and high-level duration to frequency and duty cycle.
615 -
616 -**Frequency:**
617 -
618 -(% class="MsoNormal" %)
619 -(% lang="EN-US" %)If (% style="background-attachment:initial; background-clip:initial; background-image:initial; background-origin:initial; background-position:initial; background-repeat:initial; background-size:initial; color:blue; font-family:Arial,sans-serif" %)**AT+PWMSET**(%%)**=0, **(% lang="EN-US" %)Frequency= 1000000/(%%)Pulse period(HZ);
620 -
621 -(% class="MsoNormal" %)
622 -(% lang="EN-US" %)If (% style="background-attachment:initial; background-clip:initial; background-image:initial; background-origin:initial; background-position:initial; background-repeat:initial; background-size:initial; color:blue; font-family:Arial,sans-serif" %)**AT+PWMSET**(%%)**=1, **(% lang="EN-US" %)Frequency= 1000/(%%)Pulse period(HZ);
623 -
624 -
625 -(% class="MsoNormal" %)
626 -**Duty cycle:**
627 -
628 -Duty cycle= Duration of high level/ Pulse period*100 ~(%).
629 -
630 -[[image:image-20230818092200-1.png||height="344" width="627"]]
631 -
632 -
633 -===== 2.3.2.10.b  Downlink, PWM output =====
634 -
635 -
636 -[[image:image-20230817173800-3.png||height="412" width="685"]]
637 -
638 -Downlink:  (% style="color:#037691" %)**0B xx xx xx yy zz zz**
639 -
640 - xx xx xx is the output frequency, the unit is HZ.
641 -
642 - yy is the duty cycle of the output, the unit is %.
643 -
644 - zz zz is the time delay of the output, the unit is ms.
645 -
646 -
647 -For example, send a downlink command: 0B 00 61 A8 32 13 88, the frequency is 25KHZ, the duty cycle is 50, and the output time is 5 seconds.
648 -
649 -The oscilloscope displays as follows:
650 -
651 -[[image:image-20230817173858-5.png||height="694" width="921"]]
652 -
653 -
654 654  === 2.3.3  ​Decode payload ===
655 655  
656 656  
... ... @@ -660,13 +660,13 @@
660 660  
661 661  The payload decoder function for TTN V3 are here:
662 662  
663 -SN50v3-LB TTN V3 Payload Decoder:  [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>url:https://github.com/dragino/dragino-end-node-decoder]]
601 +SN50v3 TTN V3 Payload Decoder:  [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>url:https://github.com/dragino/dragino-end-node-decoder]]
664 664  
665 665  
666 666  ==== 2.3.3.1 Battery Info ====
667 667  
668 668  
669 -Check the battery voltage for SN50v3-LB.
607 +Check the battery voltage for SN50v3.
670 670  
671 671  Ex1: 0x0B45 = 2885mV
672 672  
... ... @@ -714,24 +714,19 @@
714 714  ==== 2.3.3.4  Analogue Digital Converter (ADC) ====
715 715  
716 716  
717 -The measuring range of the ADC is only about 0.1V to 1.1V The voltage resolution is about 0.24mv.
655 +The measuring range of the ADC is only about 0V to 1.1V The voltage resolution is about 0.24mv.
718 718  
719 -When the measured output voltage of the sensor is not within the range of 0.1V and 1.1V, the output voltage terminal of the sensor shall be divided The example in the following figure is to reduce the output voltage of the sensor by three times If it is necessary to reduce more times, calculate according to the formula in the figure and connect the corresponding resistance in series.
657 +When the measured output voltage of the sensor is not within the range of 0V and 1.1V, the output voltage terminal of the sensor shall be divided The example in the following figure is to reduce the output voltage of the sensor by three times If it is necessary to reduce more times, calculate according to the formula in the figure and connect the corresponding resistance in series.
720 720  
721 721  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220628150112-1.png?width=285&height=241&rev=1.1||alt="image-20220628150112-1.png" height="241" width="285"]]
722 722  
723 -
724 724  (% style="color:red" %)**Note: If the ADC type sensor needs to be powered by SN50_v3, it is recommended to use +5V to control its switch.Only sensors with low power consumption can be powered with VDD.**
725 725  
726 726  
727 -The position of PA5 on the hardware after **LSN50 v3.3** is changed to the position shown in the figure below, and the collected voltage becomes one-sixth of the original.
728 -
729 -[[image:image-20230811113449-1.png||height="370" width="608"]]
730 -
731 731  ==== 2.3.3.5 Digital Interrupt ====
732 732  
733 733  
734 -Digital Interrupt refers to pin PA8, and there are different trigger methods. When there is a trigger, the SN50v3-LB will send a packet to the server.
667 +Digital Interrupt refers to pin PA8, and there are different trigger methods. When there is a trigger, the SN50v3 will send a packet to the server.
735 735  
736 736  (% style="color:blue" %)** Interrupt connection method:**
737 737  
... ... @@ -744,18 +744,18 @@
744 744  
745 745  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/1656379210849-860.png?rev=1.1||alt="1656379210849-860.png"]]
746 746  
747 -When the two pieces are close to each other, the 2 wire output will be short or open (depending on the type), while if the two pieces are away from each other, the 2 wire output will be the opposite status. So we can use SN50v3-LB interrupt interface to detect the status for the door or window.
680 +When the two pieces are close to each other, the 2 wire output will be short or open (depending on the type), while if the two pieces are away from each other, the 2 wire output will be the opposite status. So we can use SN50_v3 interrupt interface to detect the status for the door or window.
748 748  
749 749  
750 750  (% style="color:blue" %)**Below is the installation example:**
751 751  
752 -Fix one piece of the magnetic sensor to the door and connect the two pins to SN50v3-LB as follows:
685 +Fix one piece of the magnetic sensor to the door and connect the two pins to SN50_v3 as follows:
753 753  
754 754  * (((
755 -One pin to SN50v3-LB's PA8 pin
688 +One pin to SN50_v3's PA8 pin
756 756  )))
757 757  * (((
758 -The other pin to SN50v3-LB's VDD pin
691 +The other pin to SN50_v3's VDD pin
759 759  )))
760 760  
761 761  Install the other piece to the door. Find a place where the two pieces will be close to each other when the door is closed. For this particular magnetic sensor, when the door is closed, the output will be short, and PA8 will be at the VCC voltage.
... ... @@ -772,7 +772,7 @@
772 772  
773 773  The command is:
774 774  
775 -(% style="color:blue" %)**AT+INTMOD1=1   ** (%%) ~/~/  (more info about INMOD please refer** **[[**AT Command Manual**>>url:http://www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/&file=DRAGINO_LSN50_AT_Commands_v1.5.1.pdf]]**. **)
708 +(% style="color:blue" %)**AT+INTMOD1=1   ** (%%) ~/~/(more info about INMOD please refer** **[[**AT Command Manual**>>url:http://www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/&file=DRAGINO_LSN50_AT_Commands_v1.5.1.pdf]]**. **)
776 776  
777 777  Below shows some screen captures in TTN V3:
778 778  
... ... @@ -779,7 +779,7 @@
779 779  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/1656379339508-835.png?rev=1.1||alt="1656379339508-835.png"]]
780 780  
781 781  
782 -In **MOD=1**, user can use byte 6 to see the status for door open or close. TTN V3 decoder is as below:
715 +In MOD=1, user can use byte 6 to see the status for door open or close. TTN V3 decoder is as below:
783 783  
784 784  door= (bytes[6] & 0x80)? "CLOSE":"OPEN";
785 785  
... ... @@ -791,13 +791,12 @@
791 791  
792 792  We have made an example to show how to use the I2C interface to connect to the SHT20/ SHT31 Temperature and Humidity Sensor.
793 793  
794 -(% style="color:red" %)**Notice: Different I2C sensors have different I2C commands set and initiate process, if user want to use other I2C sensors, User need to re-write the source code to support those sensors. SHT20/ SHT31 code in SN50v3-LB will be a good reference.**
727 +Notice: Different I2C sensors have different I2C commands set and initiate process, if user want to use other I2C sensors, User need to re-write the source code to support those sensors. SHT20/ SHT31 code in SN50_v3 will be a good reference.
795 795  
796 -
797 797  Below is the connection to SHT20/ SHT31. The connection is as below:
798 798  
799 -[[image:image-20230610170152-2.png||height="501" width="846"]]
800 800  
732 +[[image:image-20230513103633-3.png||height="448" width="716"]]
801 801  
802 802  The device will be able to get the I2C sensor data now and upload to IoT Server.
803 803  
... ... @@ -825,7 +825,7 @@
825 825  
826 826  This Fundamental Principles of this sensor can be found at this link: [[https:~~/~~/wiki.dfrobot.com/Weather_-_proof_Ultrasonic_Sensor_with_Separate_Probe_SKU~~_~~__SEN0208>>url:https://wiki.dfrobot.com/Weather_-_proof_Ultrasonic_Sensor_with_Separate_Probe_SKU___SEN0208]]
827 827  
828 -The SN50v3-LB detects the pulse width of the sensor and converts it to mm output. The accuracy will be within 1 centimeter. The usable range (the distance between the ultrasonic probe and the measured object) is between 24cm and 600cm.
760 +The SN50_v3 detects the pulse width of the sensor and converts it to mm output. The accuracy will be within 1 centimeter. The usable range (the distance between the ultrasonic probe and the measured object) is between 24cm and 600cm.
829 829  
830 830  The working principle of this sensor is similar to the (% style="color:blue" %)**HC-SR04**(%%) ultrasonic sensor.
831 831  
... ... @@ -834,7 +834,7 @@
834 834  [[image:image-20230512173903-6.png||height="596" width="715"]]
835 835  
836 836  
837 -Connect to the SN50v3-LB and run (% style="color:blue" %)**AT+MOD=2**(%%) to switch to ultrasonic mode (ULT).
769 +Connect to the SN50_v3 and run (% style="color:blue" %)**AT+MOD=2**(%%) to switch to ultrasonic mode (ULT).
838 838  
839 839  The ultrasonic sensor uses the 8^^th^^ and 9^^th^^ byte for the measurement value.
840 840  
... ... @@ -846,13 +846,13 @@
846 846  ==== 2.3.3.9  Battery Output - BAT pin ====
847 847  
848 848  
849 -The BAT pin of SN50v3-LB is connected to the Battery directly. If users want to use BAT pin to power an external sensor. User need to make sure the external sensor is of low power consumption. Because the BAT pin is always open. If the external sensor is of high power consumption. the battery of SN50v3-LB will run out very soon.
781 +The BAT pin of SN50v3 is connected to the Battery directly. If users want to use BAT pin to power an external sensor. User need to make sure the external sensor is of low power consumption. Because the BAT pin is always open. If the external sensor is of high power consumption. the battery of SN50v3-LB will run out very soon.
850 850  
851 851  
852 852  ==== 2.3.3.10  +5V Output ====
853 853  
854 854  
855 -SN50v3-LB will enable +5V output before all sampling and disable the +5v after all sampling. 
787 +SN50v3 will enable +5V output before all sampling and disable the +5v after all sampling. 
856 856  
857 857  The 5V output time can be controlled by AT Command.
858 858  
... ... @@ -860,7 +860,7 @@
860 860  
861 861  Means set 5V valid time to have 1000ms. So the real 5V output will actually have 1000ms + sampling time for other sensors.
862 862  
863 -By default the **AT+5VT=500**. If the external sensor which require 5v and require more time to get stable state, user can use this command to increase the power ON duration for this sensor.
795 +By default the AT+5VT=500. If the external sensor which require 5v and require more time to get stable state, user can use this command to increase the power ON duration for this sensor.
864 864  
865 865  
866 866  ==== 2.3.3.11  BH1750 Illumination Sensor ====
... ... @@ -874,30 +874,9 @@
874 874  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220628110012-12.png?rev=1.1||alt="image-20220628110012-12.png" height="361" width="953"]]
875 875  
876 876  
877 -==== 2.3.3.12  PWM MOD ====
809 +==== 2.3.3.12  Working MOD ====
878 878  
879 879  
880 -* (((
881 -The maximum voltage that the SDA pin of SN50v3 can withstand is 3.6V, and it cannot exceed this voltage value, otherwise the chip may be burned.
882 -)))
883 -* (((
884 -If the PWM pin connected to the SDA pin cannot maintain a high level when it is not working, you need to remove the resistor R2 or replace it with a resistor with a larger resistance, otherwise a sleep current of about 360uA will be generated. The position of the resistor is shown in the figure below:
885 -)))
886 -
887 - [[image:image-20230817183249-3.png||height="320" width="417"]]
888 -
889 -* (((
890 -The signal captured by the input should preferably be processed by hardware filtering and then connected in. The software processing method is to capture four values, discard the first captured value, and then take the middle value of the second, third, and fourth captured values.
891 -)))
892 -* (((
893 -Since the device can only detect a pulse period of 50ms when [[AT+PWMSET=0>>||anchor="H3.3.8PWMsetting"]] (counting in microseconds), it is necessary to change the value of PWMSET according to the frequency of input capture.
894 -
895 -
896 -)))
897 -
898 -==== 2.3.3.13  Working MOD ====
899 -
900 -
901 901  The working MOD info is contained in the Digital in & Digital Interrupt byte (7^^th^^ Byte).
902 902  
903 903  User can use the 3^^rd^^ ~~ 7^^th^^  bit of this byte to see the working mod:
... ... @@ -913,8 +913,9 @@
913 913  * 6: MOD7
914 914  * 7: MOD8
915 915  * 8: MOD9
916 -* 9: MOD10
917 917  
828 +
829 +
918 918  == 2.4 Payload Decoder file ==
919 919  
920 920  
... ... @@ -944,6 +944,8 @@
944 944  * AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]].
945 945  * LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
946 946  
859 +
860 +
947 947  == 3.2 General Commands ==
948 948  
949 949  
... ... @@ -960,7 +960,7 @@
960 960  == 3.3 Commands special design for SN50v3-LB ==
961 961  
962 962  
963 -These commands only valid for SN50v3-LB, as below:
877 +These commands only valid for S31x-LB, as below:
964 964  
965 965  
966 966  === 3.3.1 Set Transmit Interval Time ===
... ... @@ -971,7 +971,7 @@
971 971  (% style="color:blue" %)**AT Command: AT+TDC**
972 972  
973 973  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
974 -|=(% style="width: 156px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 137px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**Response**
888 +|=(% style="width: 156px;background-color:#D9E2F3" %)**Command Example**|=(% style="width: 137px;background-color:#D9E2F3" %)**Function**|=(% style="background-color:#D9E2F3" %)**Response**
975 975  |(% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|(((
976 976  30000
977 977  OK
... ... @@ -991,14 +991,16 @@
991 991  * Example 1: Downlink Payload: 0100001E  ~/~/  Set Transmit Interval (TDC) = 30 seconds
992 992  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
993 993  
908 +
909 +
994 994  === 3.3.2 Get Device Status ===
995 995  
996 996  
997 997  Send a LoRaWAN downlink to ask the device to send its status.
998 998  
999 -(% style="color:blue" %)**Downlink Payload: 0x26 01**
915 +(% style="color:blue" %)**Downlink Payload:  **(%%)0x26 01
1000 1000  
1001 -Sensor will upload Device Status via **FPORT=5**. See payload section for detail.
917 +Sensor will upload Device Status via FPORT=5. See payload section for detail.
1002 1002  
1003 1003  
1004 1004  === 3.3.3 Set Interrupt Mode ===
... ... @@ -1009,7 +1009,7 @@
1009 1009  (% style="color:blue" %)**AT Command: AT+INTMOD1,AT+INTMOD2,AT+INTMOD3**
1010 1010  
1011 1011  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
1012 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
928 +|=(% style="width: 154px;background-color:#D9E2F3" %)**Command Example**|=(% style="width: 196px;background-color:#D9E2F3" %)**Function**|=(% style="width: 157px;background-color:#D9E2F3" %)**Response**
1013 1013  |(% style="width:154px" %)AT+INTMOD1=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)(((
1014 1014  0
1015 1015  OK
... ... @@ -1024,6 +1024,7 @@
1024 1024  )))|(% style="width:157px" %)OK
1025 1025  |(% style="width:154px" %)AT+INTMOD2=3|(% style="width:196px" %)(((
1026 1026  Set Transmit Interval
943 +
1027 1027  trigger by rising edge.
1028 1028  )))|(% style="width:157px" %)OK
1029 1029  |(% style="width:154px" %)AT+INTMOD3=0|(% style="width:196px" %)Disable Interrupt|(% style="width:157px" %)OK
... ... @@ -1039,6 +1039,8 @@
1039 1039  * Example 3: Downlink Payload: 06000102  **~-~-->**  AT+INTMOD2=2
1040 1040  * Example 4: Downlink Payload: 06000201  **~-~-->**  AT+INTMOD3=1
1041 1041  
959 +
960 +
1042 1042  === 3.3.4 Set Power Output Duration ===
1043 1043  
1044 1044  
... ... @@ -1053,7 +1053,7 @@
1053 1053  (% style="color:blue" %)**AT Command: AT+5VT**
1054 1054  
1055 1055  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
1056 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
975 +|=(% style="width: 154px;background-color:#D9E2F3" %)**Command Example**|=(% style="width: 196px;background-color:#D9E2F3" %)**Function**|=(% style="width: 157px;background-color:#D9E2F3" %)**Response**
1057 1057  |(% style="width:154px" %)AT+5VT=?|(% style="width:196px" %)Show 5V open time.|(% style="width:157px" %)(((
1058 1058  500(default)
1059 1059  OK
... ... @@ -1071,6 +1071,8 @@
1071 1071  * Example 1: Downlink Payload: 070000  **~-~-->**  AT+5VT=0
1072 1072  * Example 2: Downlink Payload: 0701F4  **~-~-->**  AT+5VT=500
1073 1073  
993 +
994 +
1074 1074  === 3.3.5 Set Weighing parameters ===
1075 1075  
1076 1076  
... ... @@ -1079,7 +1079,7 @@
1079 1079  (% style="color:blue" %)**AT Command: AT+WEIGRE,AT+WEIGAP**
1080 1080  
1081 1081  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
1082 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1003 +|=(% style="width: 154px;background-color:#D9E2F3" %)**Command Example**|=(% style="width: 196px;background-color:#D9E2F3" %)**Function**|=(% style="width: 157px;background-color:#D9E2F3" %)**Response**
1083 1083  |(% style="width:154px" %)AT+WEIGRE|(% style="width:196px" %)Weight is initialized to 0.|(% style="width:157px" %)OK
1084 1084  |(% style="width:154px" %)AT+WEIGAP=?|(% style="width:196px" %)400.0|(% style="width:157px" %)OK(default)
1085 1085  |(% style="width:154px" %)AT+WEIGAP=400.3|(% style="width:196px" %)Set the factor to 400.3.|(% style="width:157px" %)OK
... ... @@ -1096,6 +1096,8 @@
1096 1096  * Example 2: Downlink Payload: 08020FA3  **~-~-->**  AT+WEIGAP=400.3
1097 1097  * Example 3: Downlink Payload: 08020FA0  **~-~-->**  AT+WEIGAP=400.0
1098 1098  
1020 +
1021 +
1099 1099  === 3.3.6 Set Digital pulse count value ===
1100 1100  
1101 1101  
... ... @@ -1106,7 +1106,7 @@
1106 1106  (% style="color:blue" %)**AT Command: AT+SETCNT**
1107 1107  
1108 1108  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
1109 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1032 +|=(% style="width: 154px;background-color:#D9E2F3" %)**Command Example**|=(% style="width: 196px;background-color:#D9E2F3" %)**Function**|=(% style="width: 157px;background-color:#D9E2F3" %)**Response**
1110 1110  |(% style="width:154px" %)AT+SETCNT=1,100|(% style="width:196px" %)Initialize the count value 1 to 100.|(% style="width:157px" %)OK
1111 1111  |(% style="width:154px" %)AT+SETCNT=2,0|(% style="width:196px" %)Initialize the count value 2 to 0.|(% style="width:157px" %)OK
1112 1112  
... ... @@ -1119,6 +1119,8 @@
1119 1119  * Example 1: Downlink Payload: 090100000000  **~-~-->**  AT+SETCNT=1,0
1120 1120  * Example 2: Downlink Payload: 0902000003E8  **~-~-->**  AT+SETCNT=2,1000
1121 1121  
1045 +
1046 +
1122 1122  === 3.3.7 Set Workmode ===
1123 1123  
1124 1124  
... ... @@ -1127,7 +1127,7 @@
1127 1127  (% style="color:blue" %)**AT Command: AT+MOD**
1128 1128  
1129 1129  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
1130 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1055 +|=(% style="width: 154px;background-color:#D9E2F3" %)**Command Example**|=(% style="width: 196px;background-color:#D9E2F3" %)**Function**|=(% style="width: 157px;background-color:#D9E2F3" %)**Response**
1131 1131  |(% style="width:154px" %)AT+MOD=?|(% style="width:196px" %)Get the current working mode.|(% style="width:157px" %)(((
1132 1132  OK
1133 1133  )))
... ... @@ -1143,32 +1143,8 @@
1143 1143  * Example 1: Downlink Payload: 0A01  **~-~-->**  AT+MOD=1
1144 1144  * Example 2: Downlink Payload: 0A04  **~-~-->**  AT+MOD=4
1145 1145  
1146 -=== 3.3.8 PWM setting ===
1147 1147  
1148 -Feature: Set the time acquisition unit for PWM input capture.
1149 1149  
1150 -(% style="color:blue" %)**AT Command: AT+PWMSET**
1151 -
1152 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
1153 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1154 -|(% style="width:154px" %)AT+PWMSET=?|(% style="width:196px" %)0|(% style="width:157px" %)(((
1155 -0(default)
1156 -
1157 -OK
1158 -)))
1159 -|(% style="width:154px" %)AT+PWMSET=0|(% style="width:196px" %)The unit of PWM capture time is microsecond. The capture frequency range is between 20HZ and 100000HZ.   |(% style="width:157px" %)(((
1160 -OK
1161 -
1162 -)))
1163 -|(% style="width:154px" %)AT+PWMSET=1|(% style="width:196px" %)The unit of PWM capture time is millisecond.  The capture frequency range is between 5HZ and 250HZ. |(% style="width:157px" %)OK
1164 -
1165 -(% style="color:blue" %)**Downlink Command: 0x0C**
1166 -
1167 -Format: Command Code (0x0C) followed by 1 bytes.
1168 -
1169 -* Example 1: Downlink Payload: 0C00  **~-~-->**  AT+PWMSET=0
1170 -* Example 2: Downlink Payload: 0C01  **~-~-->**  AT+PWMSET=1
1171 -
1172 1172  = 4. Battery & Power Consumption =
1173 1173  
1174 1174  
... ... @@ -1181,19 +1181,22 @@
1181 1181  
1182 1182  
1183 1183  (% class="wikigeneratedid" %)
1184 -**User can change firmware SN50v3-LB to:**
1085 +User can change firmware SN50v3-LB to:
1185 1185  
1186 1186  * Change Frequency band/ region.
1187 1187  * Update with new features.
1188 1188  * Fix bugs.
1189 1189  
1190 -**Firmware and changelog can be downloaded from :** **[[Firmware download link>>https://www.dropbox.com/sh/4rov7bcp6u28exp/AACt-wAySd4si5AXi8DBmvSca?dl=0]]**
1091 +Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0]]**
1191 1191  
1192 -**Methods to Update Firmware:**
1193 1193  
1194 -* (Recommanded way) OTA firmware update via wireless: **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]**
1195 -* Update through UART TTL interface: **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
1094 +Methods to Update Firmware:
1196 1196  
1096 +* (Recommanded way) OTA firmware update via wireless:   [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
1097 +* Update through UART TTL interface.**[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
1098 +
1099 +
1100 +
1197 1197  = 6. FAQ =
1198 1198  
1199 1199  == 6.1 Where can i find source code of SN50v3-LB? ==
... ... @@ -1202,22 +1202,8 @@
1202 1202  * **[[Hardware Source Files>>https://github.com/dragino/Lora/tree/master/LSN50/v3.0]].**
1203 1203  * **[[Software Source Code & Compile instruction>>https://github.com/dragino/SN50v3]].**
1204 1204  
1205 -== 6.2 How to generate PWM Output in SN50v3-LB? ==
1206 1206  
1207 1207  
1208 -See this document: **[[Generate PWM Output on SN50v3>>https://www.dropbox.com/scl/fi/r3trcet2knujg40w0mgyn/Generate-PWM-Output-on-SN50v3.pdf?rlkey=rxsgmrhhrv62iiiwjq9sv10bn&dl=0]]**.
1209 -
1210 -
1211 -== 6.3 How to put several sensors to a SN50v3-LB? ==
1212 -
1213 -
1214 -When we want to put several sensors to A SN50v3-LB, the waterproof at the grand connector will become an issue. User can try to exchange the grand connector to below type.
1215 -
1216 -[[Reference Supplier>>https://www.yscableglands.com/cable-glands/nylon-cable-glands/cable-gland-rubber-seal.html]].
1217 -
1218 -[[image:image-20230810121434-1.png||height="242" width="656"]]
1219 -
1220 -
1221 1221  = 7. Order Info =
1222 1222  
1223 1223  
... ... @@ -1241,6 +1241,8 @@
1241 1241  * (% style="color:red" %)**20**(%%): With M20 waterproof cable hole
1242 1242  * (% style="color:red" %)**NH**(%%): No Hole
1243 1243  
1134 +
1135 +
1244 1244  = 8. ​Packing Info =
1245 1245  
1246 1246  
... ... @@ -1255,6 +1255,8 @@
1255 1255  * Package Size / pcs : cm
1256 1256  * Weight / pcs : g
1257 1257  
1150 +
1151 +
1258 1258  = 9. Support =
1259 1259  
1260 1260  
image-20230610162852-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -695.7 KB
Content
image-20230610163213-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -695.4 KB
Content
image-20230610170047-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -444.9 KB
Content
image-20230610170152-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -359.5 KB
Content
image-20230810121434-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -137.3 KB
Content
image-20230811113449-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -973.1 KB
Content
image-20230817170702-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -39.6 KB
Content
image-20230817172209-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -1.3 MB
Content
image-20230817173800-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -1.1 MB
Content
image-20230817173830-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -508.5 KB
Content
image-20230817173858-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -1.6 MB
Content
image-20230817183137-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -137.1 KB
Content
image-20230817183218-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -137.1 KB
Content
image-20230817183249-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -948.6 KB
Content
image-20230818092200-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -98.9 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0