From version < 74.1 >
edited by Saxer Lin
on 2023/08/18 09:51
To version < 70.1 >
edited by Saxer Lin
on 2023/08/17 18:34
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -609,24 +609,13 @@
609 609  [[image:image-20230817170702-1.png||height="161" width="1044"]]
610 610  
611 611  
612 -When the device detects the following PWM signal ,decoder will converts the pulse period and high-level duration to frequency and duty cycle.
612 +(% style="color:blue" %)**AT+PWMSET=AA(Default is 0)  ==> Corresponding downlink: 0B AA**
613 613  
614 -Frequency
614 +When AA is 0, the unit of PWM capture time is microsecond. The capture frequency range is between 20HZ and 100000HZ.  
615 615  
616 -(% class="MsoNormal" %)
617 -(% lang="EN-US" %)If (% style="background-attachment:initial; background-clip:initial; background-image:initial; background-origin:initial; background-position:initial; background-repeat:initial; background-size:initial; color:blue; font-family:Arial,sans-serif" %)**AT+PWMSET**(%%)**=0,**(% lang="EN-US" %)Frequency= 1000000/(%%)Pulse period(HZ);
616 +When AA is 1, the unit of PWM capture time is millisecond.  The capture frequency range is between 5HZ and 250HZ.  
618 618  
619 -(% class="MsoNormal" %)
620 -(% lang="EN-US" %)If (% style="background-attachment:initial; background-clip:initial; background-image:initial; background-origin:initial; background-position:initial; background-repeat:initial; background-size:initial; color:blue; font-family:Arial,sans-serif" %)**AT+PWMSET**(%%)**=1,**(% lang="EN-US" %)Frequency= 1000/(%%)Pulse period(HZ);
621 621  
622 -(% class="MsoNormal" %)
623 -Duty cycle:
624 -
625 -Duty cycle= Duration of high level/ Pulse period*100 ~(%).
626 -
627 -[[image:image-20230818092200-1.png||height="344" width="627"]]
628 -
629 -
630 630  ===== 2.3.2.10.b  Downlink, PWM output =====
631 631  
632 632  [[image:image-20230817173800-3.png||height="412" width="685"]]
... ... @@ -886,7 +886,7 @@
886 886  The signal captured by the input should preferably be processed by hardware filtering and then connected in. The software processing method is to capture four values, discard the first captured value, and then take the middle value of the second, third, and fourth captured values.
887 887  )))
888 888  * (((
889 -Since the device can only detect a pulse period of 50ms when [[AT+PWMSET=0>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SN50v3-LB/#H3.3.8PWMsetting]] (counting in microseconds), it is necessary to change the value of PWMSET according to the frequency of input capture.
878 +Since the device can only detect a pulse period of 50ms when AT+PWMSET=0 (counting in microseconds), it is necessary to change the value of PWMSET according to the frequency of input capture.
890 890  
891 891  
892 892  )))
... ... @@ -1139,32 +1139,6 @@
1139 1139  * Example 1: Downlink Payload: 0A01  **~-~-->**  AT+MOD=1
1140 1140  * Example 2: Downlink Payload: 0A04  **~-~-->**  AT+MOD=4
1141 1141  
1142 -=== 3.3.8 PWM setting ===
1143 -
1144 -Feature: Set the time acquisition unit for PWM input capture.
1145 -
1146 -(% style="color:blue" %)**AT Command: AT+PWMSET**
1147 -
1148 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
1149 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1150 -|(% style="width:154px" %)AT+PWMSET=?|(% style="width:196px" %)0|(% style="width:157px" %)(((
1151 -0(default)
1152 -
1153 -OK
1154 -)))
1155 -|(% style="width:154px" %)AT+PWMSET=0|(% style="width:196px" %)The unit of PWM capture time is microsecond. The capture frequency range is between 20HZ and 100000HZ.   |(% style="width:157px" %)(((
1156 -OK
1157 -
1158 -)))
1159 -|(% style="width:154px" %)AT+PWMSET=1|(% style="width:196px" %)The unit of PWM capture time is millisecond.  The capture frequency range is between 5HZ and 250HZ. |(% style="width:157px" %)OK
1160 -
1161 -(% style="color:blue" %)**Downlink Command: 0x0C**
1162 -
1163 -Format: Command Code (0x0C) followed by 1 bytes.
1164 -
1165 -* Example 1: Downlink Payload: 0C00  **~-~-->**  AT+PWMSET=0
1166 -* Example 2: Downlink Payload: 0C01  **~-~-->**  AT+PWMSET=1
1167 -
1168 1168  = 4. Battery & Power Consumption =
1169 1169  
1170 1170  
image-20230818092200-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -98.9 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0