From version < 73.1 >
edited by Saxer Lin
on 2023/08/18 09:50
To version < 69.1 >
edited by Saxer Lin
on 2023/08/17 18:33
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -609,43 +609,13 @@
609 609  [[image:image-20230817170702-1.png||height="161" width="1044"]]
610 610  
611 611  
612 -When the device detects the following PWM signal ,decoder will converts the pulse period and high-level duration to frequency and duty cycle.
612 +(% style="color:blue" %)**AT+PWMSET=AA(Default is 0)  ==> Corresponding downlink: 0B AA**
613 613  
614 -Frequency
614 +When AA is 0, the unit of PWM capture time is microsecond. The capture frequency range is between 20HZ and 100000HZ.  
615 615  
616 -(% class="MsoNormal" %)
617 -(% lang="EN-US" %)If (% style="background-attachment:initial; background-clip:initial; background-image:initial; background-origin:initial; background-position:initial; background-repeat:initial; background-size:initial; color:blue; font-family:Arial,sans-serif" %)**AT+PWMSET**(%%)**=0 ,**
616 +When AA is 1, the unit of PWM capture time is millisecond.  The capture frequency range is between 5HZ and 250HZ.  
618 618  
619 -(((
620 -
621 621  
622 -(% lang="EN-US" %)Frequency= 1000000/(%%)Pulse period(HZ);
623 -)))
624 -
625 -(% class="MsoNormal" %)
626 -(% lang="EN-US" %)If (% style="background-attachment:initial; background-clip:initial; background-image:initial; background-origin:initial; background-position:initial; background-repeat:initial; background-size:initial; color:blue; font-family:Arial,sans-serif" %)**AT+PWMSET**(%%)**=1 ,**
627 -
628 -(((
629 -
630 -
631 -(% lang="EN-US" %)Frequency= 1000/(%%)Pulse period(HZ);
632 -)))
633 -
634 -(% class="MsoNormal" %)
635 -Duty cycle:
636 -
637 -Duty cycle= Duration of high level/ Pulse period*100 ~(%).
638 -
639 -
640 -
641 -(((
642 -
643 -)))
644 -
645 -
646 -[[image:image-20230818092200-1.png||height="344" width="627"]]
647 -
648 -
649 649  ===== 2.3.2.10.b  Downlink, PWM output =====
650 650  
651 651  [[image:image-20230817173800-3.png||height="412" width="685"]]
... ... @@ -905,11 +905,10 @@
905 905  The signal captured by the input should preferably be processed by hardware filtering and then connected in. The software processing method is to capture four values, discard the first captured value, and then take the middle value of the second, third, and fourth captured values.
906 906  )))
907 907  * (((
908 -Since the device can only detect a pulse period of 50ms when [[AT+PWMSET=0>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SN50v3-LB/#H3.3.8PWMsetting]] (counting in microseconds), it is necessary to change the value of PWMSET according to the frequency of input capture.
909 -
910 -
878 +Since the device can only detect a pulse period of 50ms when AT+PWMSET=0 (counting in microseconds), it is necessary to change the value of PWMSET according to the frequency of input capture.
911 911  )))
912 912  
881 +
913 913  ==== 2.3.3.13  Working MOD ====
914 914  
915 915  
... ... @@ -1158,33 +1158,6 @@
1158 1158  * Example 1: Downlink Payload: 0A01  **~-~-->**  AT+MOD=1
1159 1159  * Example 2: Downlink Payload: 0A04  **~-~-->**  AT+MOD=4
1160 1160  
1161 -
1162 -=== 3.3.8 PWM setting ===
1163 -
1164 -Feature: Set the time acquisition unit for PWM input capture.
1165 -
1166 -(% style="color:blue" %)**AT Command: AT+PWMSET**
1167 -
1168 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
1169 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1170 -|(% style="width:154px" %)AT+PWMSET=?|(% style="width:196px" %)0|(% style="width:157px" %)(((
1171 -0(default)
1172 -
1173 -OK
1174 -)))
1175 -|(% style="width:154px" %)AT+PWMSET=0|(% style="width:196px" %)The unit of PWM capture time is microsecond. The capture frequency range is between 20HZ and 100000HZ.   |(% style="width:157px" %)(((
1176 -OK
1177 -
1178 -)))
1179 -|(% style="width:154px" %)AT+PWMSET=1|(% style="width:196px" %)The unit of PWM capture time is millisecond.  The capture frequency range is between 5HZ and 250HZ. |(% style="width:157px" %)OK
1180 -
1181 -(% style="color:blue" %)**Downlink Command: 0x0C**
1182 -
1183 -Format: Command Code (0x0C) followed by 1 bytes.
1184 -
1185 -* Example 1: Downlink Payload: 0C00  **~-~-->**  AT+PWMSET=0
1186 -* Example 2: Downlink Payload: 0C01  **~-~-->**  AT+PWMSET=1
1187 -
1188 1188  = 4. Battery & Power Consumption =
1189 1189  
1190 1190  
image-20230818092200-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -98.9 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0