Changes for page SN50v3-LB/LS -- LoRaWAN Sensor Node User Manual
Last modified by Bei Jinggeng on 2025/01/10 15:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -617,8 +617,8 @@ 617 617 (% lang="EN-US" %)If (% style="background-attachment:initial; background-clip:initial; background-image:initial; background-origin:initial; background-position:initial; background-repeat:initial; background-size:initial; color:blue; font-family:Arial,sans-serif" %)**AT+PWMSET**(%%)**=0 ,** 618 618 619 619 ((( 620 + 620 620 621 - 622 622 (% lang="EN-US" %)Frequency= 1000000/(%%)Pulse period(HZ); 623 623 ))) 624 624 ... ... @@ -626,8 +626,8 @@ 626 626 (% lang="EN-US" %)If (% style="background-attachment:initial; background-clip:initial; background-image:initial; background-origin:initial; background-position:initial; background-repeat:initial; background-size:initial; color:blue; font-family:Arial,sans-serif" %)**AT+PWMSET**(%%)**=1 ,** 627 627 628 628 ((( 629 + 629 629 630 - 631 631 (% lang="EN-US" %)Frequency= 1000/(%%)Pulse period(HZ); 632 632 ))) 633 633 ... ... @@ -636,11 +636,10 @@ 636 636 637 637 Duty cycle= Duration of high level/ Pulse period*100 ~(%). 638 638 639 -(% class="MsoNormal" %) 640 640 641 641 642 642 ((( 643 - 642 + 644 644 ))) 645 645 646 646 ... ... @@ -906,7 +906,7 @@ 906 906 The signal captured by the input should preferably be processed by hardware filtering and then connected in. The software processing method is to capture four values, discard the first captured value, and then take the middle value of the second, third, and fourth captured values. 907 907 ))) 908 908 * ((( 909 -Since the device can only detect a pulse period of 50ms when AT+PWMSET=0 (counting in microseconds), it is necessary to change the value of PWMSET according to the frequency of input capture. 908 +Since the device can only detect a pulse period of 50ms when [[AT+PWMSET=0>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SN50v3-LB/#H3.3.8PWMsetting]] (counting in microseconds), it is necessary to change the value of PWMSET according to the frequency of input capture. 910 910 911 911 912 912 ))) ... ... @@ -1160,7 +1160,6 @@ 1160 1160 * Example 2: Downlink Payload: 0A04 **~-~-->** AT+MOD=4 1161 1161 1162 1162 1163 - 1164 1164 === 3.3.8 PWM setting === 1165 1165 1166 1166 Feature: Set the time acquisition unit for PWM input capture. ... ... @@ -1187,7 +1187,6 @@ 1187 1187 * Example 1: Downlink Payload: 0C00 **~-~-->** AT+PWMSET=0 1188 1188 * Example 2: Downlink Payload: 0C01 **~-~-->** AT+PWMSET=1 1189 1189 1190 - 1191 1191 = 4. Battery & Power Consumption = 1192 1192 1193 1193