... ... @@ -609,13 +609,44 @@
609 609  [[image:image-20230817170702-1.png||height="161" width="1044"]]
610 610  
611 611  
612 -(% style="color:blue" %)**AT+PWMSET=AA(Default is 0)  ==> Corresponding downlink: 0B AA**
612 +When the device detects the following PWM signal ,decoder will converts the pulse period and high-level duration to frequency and duty cycle.
613 613  
614 -When AA is 0, the unit of PWM capture time is microsecond. The capture frequency range is between 20HZ and 100000HZ.  
614 +Frequency
615 615  
616 -When AA is 1, the unit of PWM capture time is millisecond.  The capture frequency range is between 5HZ and 250HZ.  
616 +(% class="MsoNormal" %)
617 +(% lang="EN-US" %)If (% style="background-attachment:initial; background-clip:initial; background-image:initial; background-origin:initial; background-position:initial; background-repeat:initial; background-size:initial; color:blue; font-family:Arial,sans-serif" %)**AT+PWMSET**(%%)**=0 ,**
617 617  
619 +(((
618 618  
621 +
622 +(% lang="EN-US" %)Frequency= 1000000/(%%)Pulse period(HZ);
623 +)))
624 +
625 +(% class="MsoNormal" %)
626 +(% lang="EN-US" %)If (% style="background-attachment:initial; background-clip:initial; background-image:initial; background-origin:initial; background-position:initial; background-repeat:initial; background-size:initial; color:blue; font-family:Arial,sans-serif" %)**AT+PWMSET**(%%)**=1 ,**
627 +
628 +(((
629 +
630 +
631 +(% lang="EN-US" %)Frequency= 1000/(%%)Pulse period(HZ);
632 +)))
633 +
634 +(% class="MsoNormal" %)
635 +Duty cycle:
636 +
637 +Duty cycle= Duration of high level/ Pulse period*100 ~(%).
638 +
639 +(% class="MsoNormal" %)
640 +
641 +
642 +(((
643 +
644 +)))
645 +
646 +
647 +[[image:image-20230818092200-1.png||height="344" width="627"]]
648 +
649 +
619 619  ===== 2.3.2.10.b  Downlink, PWM output =====
620 620  
621 621  [[image:image-20230817173800-3.png||height="412" width="685"]]
... ... @@ -1128,6 +1128,35 @@
1128 1128  * Example 1: Downlink Payload: 0A01  **~-~-->**  AT+MOD=1
1129 1129  * Example 2: Downlink Payload: 0A04  **~-~-->**  AT+MOD=4
1130 1130  
1162 +
1163 +
1164 +=== 3.3.8 PWM setting ===
1165 +
1166 +Feature: Set the time acquisition unit for PWM input capture.
1167 +
1168 +(% style="color:blue" %)**AT Command: AT+PWMSET**
1169 +
1170 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
1171 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1172 +|(% style="width:154px" %)AT+PWMSET=?|(% style="width:196px" %)0|(% style="width:157px" %)(((
1173 +0(default)
1174 +
1175 +OK
1176 +)))
1177 +|(% style="width:154px" %)AT+PWMSET=0|(% style="width:196px" %)The unit of PWM capture time is microsecond. The capture frequency range is between 20HZ and 100000HZ.   |(% style="width:157px" %)(((
1178 +OK
1179 +
1180 +)))
1181 +|(% style="width:154px" %)AT+PWMSET=1|(% style="width:196px" %)The unit of PWM capture time is millisecond.  The capture frequency range is between 5HZ and 250HZ. |(% style="width:157px" %)OK
1182 +
1183 +(% style="color:blue" %)**Downlink Command: 0x0C**
1184 +
1185 +Format: Command Code (0x0C) followed by 1 bytes.
1186 +
1187 +* Example 1: Downlink Payload: 0C00  **~-~-->**  AT+PWMSET=0
1188 +* Example 2: Downlink Payload: 0C01  **~-~-->**  AT+PWMSET=1
1189 +
1190 +
1131 1131  = 4. Battery & Power Consumption =
1132 1132  
1133 1133  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0