233 233  
234 234  (% style="color:#037691" %)**Frequency Band**:
235 235  
236 -0x01: EU868
236 +*0x01: EU868
237 237  
238 -0x02: US915
238 +*0x02: US915
239 239  
240 -0x03: IN865
240 +*0x03: IN865
241 241  
242 -0x04: AU915
242 +*0x04: AU915
243 243  
244 -0x05: KZ865
244 +*0x05: KZ865
245 245  
246 -0x06: RU864
246 +*0x06: RU864
247 247  
248 -0x07: AS923
248 +*0x07: AS923
249 249  
250 -0x08: AS923-1
250 +*0x08: AS923-1
251 251  
252 -0x09: AS923-2
252 +*0x09: AS923-2
253 253  
254 -0x0a: AS923-3
254 +*0x0a: AS923-3
255 255  
256 -0x0b: CN470
256 +*0x0b: CN470
257 257  
258 -0x0c: EU433
258 +*0x0c: EU433
259 259  
260 -0x0d: KR920
260 +*0x0d: KR920
261 261  
262 -0x0e: MA869
262 +*0x0e: MA869
263 263  
264 264  
265 265  (% style="color:#037691" %)**Sub-Band**:
... ... @@ -335,8 +335,9 @@
335 335  )))|(% style="width:189px" %)(((
336 336  Digital in(PB15) & Digital Interrupt(PA8)
337 337  )))|(% style="width:208px" %)(((
338 -Distance measure by: 1) LIDAR-Lite V3HP
339 -Or 2) Ultrasonic Sensor
338 +Distance measure by:1) LIDAR-Lite V3HP
339 +Or
340 +2) Ultrasonic Sensor
340 340  )))|(% style="width:117px" %)Reserved
341 341  
342 342  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/1656324539647-568.png?rev=1.1||alt="1656324539647-568.png"]]
... ... @@ -366,7 +366,8 @@
366 366  ADC(PA4)
367 367  )))|(% style="width:323px" %)(((
368 368  Distance measure by:1)TF-Mini plus LiDAR
369 -Or 2) TF-Luna LiDAR
370 +Or 
371 +2) TF-Luna LiDAR
370 370  )))|(% style="width:188px" %)Distance signal  strength
371 371  
372 372  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/1656376779088-686.png?rev=1.1||alt="1656376779088-686.png"]]
... ... @@ -473,6 +473,7 @@
473 473  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220820120036-2.png?width=1003&height=469&rev=1.1||alt="image-20220820120036-2.png" height="469" width="1003"]]
474 474  
475 475  
478 +
476 476  ==== 2.3.2.6  MOD~=6 (Counting Mode) ====
477 477  
478 478  
... ... @@ -648,9 +648,9 @@
648 648  ==== 2.3.3.4  Analogue Digital Converter (ADC) ====
649 649  
650 650  
651 -The measuring range of the ADC is only about 0.1V to 1.1V The voltage resolution is about 0.24mv.
654 +The measuring range of the ADC is only about 0V to 1.1V The voltage resolution is about 0.24mv.
652 652  
653 -When the measured output voltage of the sensor is not within the range of 0.1V and 1.1V, the output voltage terminal of the sensor shall be divided The example in the following figure is to reduce the output voltage of the sensor by three times If it is necessary to reduce more times, calculate according to the formula in the figure and connect the corresponding resistance in series.
656 +When the measured output voltage of the sensor is not within the range of 0V and 1.1V, the output voltage terminal of the sensor shall be divided The example in the following figure is to reduce the output voltage of the sensor by three times If it is necessary to reduce more times, calculate according to the formula in the figure and connect the corresponding resistance in series.
654 654  
655 655  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220628150112-1.png?width=285&height=241&rev=1.1||alt="image-20220628150112-1.png" height="241" width="285"]]
656 656  
... ... @@ -658,10 +658,6 @@
658 658  (% style="color:red" %)**Note: If the ADC type sensor needs to be powered by SN50_v3, it is recommended to use +5V to control its switch.Only sensors with low power consumption can be powered with VDD.**
659 659  
660 660  
661 -The position of PA5 on the hardware after **LSN50 v3.3** is changed to the position shown in the figure below, and the collected voltage becomes one-sixth of the original.
662 -
663 -[[image:image-20230811113449-1.png||height="370" width="608"]]
664 -
665 665  ==== 2.3.3.5 Digital Interrupt ====
666 666  
667 667  
... ... @@ -1093,8 +1093,8 @@
1093 1093  
1094 1094  **Methods to Update Firmware:**
1095 1095  
1096 -* (Recommanded way) OTA firmware update via wireless: **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]**
1097 -* Update through UART TTL interface**[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
1095 +* (Recommanded way) OTA firmware update via wireless:   [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
1096 +* Update through UART TTL interface.**[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
1098 1098  
1099 1099  
1100 1100  
... ... @@ -1108,22 +1108,6 @@
1108 1108  
1109 1109  
1110 1110  
1111 -== 6.2 How to generate PWM Output in SN50v3-LB? ==
1112 -
1113 -
1114 -See this document: **[[Generate PWM Output on SN50v3>>https://www.dropbox.com/scl/fi/r3trcet2knujg40w0mgyn/Generate-PWM-Output-on-SN50v3.pdf?rlkey=rxsgmrhhrv62iiiwjq9sv10bn&dl=0]]**.
1115 -
1116 -
1117 -== 6.3 How to put several sensors to a SN50v3-LB? ==
1118 -
1119 -
1120 -When we want to put several sensors to A SN50v3-LB, the waterproof at the grand connector will become an issue. User can try to exchange the grand connector to below type.
1121 -
1122 -[[Reference Supplier>>https://www.yscableglands.com/cable-glands/nylon-cable-glands/cable-gland-rubber-seal.html]].
1123 -
1124 -[[image:image-20230810121434-1.png||height="242" width="656"]]
1125 -
1126 -
1127 1127  = 7. Order Info =
1128 1128  
1129 1129  
image-20230810121434-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -137.3 KB
Content
image-20230811113449-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -973.1 KB
Content
image-20230817170702-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -39.6 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0