Changes for page SN50v3-LB/LS -- LoRaWAN Sensor Node User Manual
Last modified by Bei Jinggeng on 2025/01/10 15:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -233,33 +233,33 @@ 233 233 234 234 (% style="color:#037691" %)**Frequency Band**: 235 235 236 -0x01: EU868 236 +*0x01: EU868 237 237 238 -0x02: US915 238 +*0x02: US915 239 239 240 -0x03: IN865 240 +*0x03: IN865 241 241 242 -0x04: AU915 242 +*0x04: AU915 243 243 244 -0x05: KZ865 244 +*0x05: KZ865 245 245 246 -0x06: RU864 246 +*0x06: RU864 247 247 248 -0x07: AS923 248 +*0x07: AS923 249 249 250 -0x08: AS923-1 250 +*0x08: AS923-1 251 251 252 -0x09: AS923-2 252 +*0x09: AS923-2 253 253 254 -0x0a: AS923-3 254 +*0x0a: AS923-3 255 255 256 -0x0b: CN470 256 +*0x0b: CN470 257 257 258 -0x0c: EU433 258 +*0x0c: EU433 259 259 260 -0x0d: KR920 260 +*0x0d: KR920 261 261 262 -0x0e: MA869 262 +*0x0e: MA869 263 263 264 264 265 265 (% style="color:#037691" %)**Sub-Band**: ... ... @@ -335,8 +335,9 @@ 335 335 )))|(% style="width:189px" %)((( 336 336 Digital in(PB15) & Digital Interrupt(PA8) 337 337 )))|(% style="width:208px" %)((( 338 -Distance measure by: 1) LIDAR-Lite V3HP 339 -Or 2) Ultrasonic Sensor 338 +Distance measure by:1) LIDAR-Lite V3HP 339 +Or 340 +2) Ultrasonic Sensor 340 340 )))|(% style="width:117px" %)Reserved 341 341 342 342 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/1656324539647-568.png?rev=1.1||alt="1656324539647-568.png"]] ... ... @@ -650,9 +650,9 @@ 650 650 ==== 2.3.3.4 Analogue Digital Converter (ADC) ==== 651 651 652 652 653 -The measuring range of the ADC is only about 0 .1V to 1.1V The voltage resolution is about 0.24mv.654 +The measuring range of the ADC is only about 0V to 1.1V The voltage resolution is about 0.24mv. 654 654 655 -When the measured output voltage of the sensor is not within the range of 0 .1V and 1.1V, the output voltage terminal of the sensor shall be divided The example in the following figure is to reduce the output voltage of the sensor by three times If it is necessary to reduce more times, calculate according to the formula in the figure and connect the corresponding resistance in series.656 +When the measured output voltage of the sensor is not within the range of 0V and 1.1V, the output voltage terminal of the sensor shall be divided The example in the following figure is to reduce the output voltage of the sensor by three times If it is necessary to reduce more times, calculate according to the formula in the figure and connect the corresponding resistance in series. 656 656 657 657 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220628150112-1.png?width=285&height=241&rev=1.1||alt="image-20220628150112-1.png" height="241" width="285"]] 658 658 ... ... @@ -825,6 +825,8 @@ 825 825 * 7: MOD8 826 826 * 8: MOD9 827 827 829 + 830 + 828 828 == 2.4 Payload Decoder file == 829 829 830 830 ... ... @@ -854,6 +854,8 @@ 854 854 * AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]]. 855 855 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 856 856 860 + 861 + 857 857 == 3.2 General Commands == 858 858 859 859 ... ... @@ -901,6 +901,8 @@ 901 901 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 902 902 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 903 903 909 + 910 + 904 904 === 3.3.2 Get Device Status === 905 905 906 906 ... ... @@ -949,6 +949,8 @@ 949 949 * Example 3: Downlink Payload: 06000102 **~-~-->** AT+INTMOD2=2 950 950 * Example 4: Downlink Payload: 06000201 **~-~-->** AT+INTMOD3=1 951 951 959 + 960 + 952 952 === 3.3.4 Set Power Output Duration === 953 953 954 954 ... ... @@ -981,6 +981,8 @@ 981 981 * Example 1: Downlink Payload: 070000 **~-~-->** AT+5VT=0 982 982 * Example 2: Downlink Payload: 0701F4 **~-~-->** AT+5VT=500 983 983 993 + 994 + 984 984 === 3.3.5 Set Weighing parameters === 985 985 986 986 ... ... @@ -1006,6 +1006,8 @@ 1006 1006 * Example 2: Downlink Payload: 08020FA3 **~-~-->** AT+WEIGAP=400.3 1007 1007 * Example 3: Downlink Payload: 08020FA0 **~-~-->** AT+WEIGAP=400.0 1008 1008 1020 + 1021 + 1009 1009 === 3.3.6 Set Digital pulse count value === 1010 1010 1011 1011 ... ... @@ -1029,6 +1029,8 @@ 1029 1029 * Example 1: Downlink Payload: 090100000000 **~-~-->** AT+SETCNT=1,0 1030 1030 * Example 2: Downlink Payload: 0902000003E8 **~-~-->** AT+SETCNT=2,1000 1031 1031 1045 + 1046 + 1032 1032 === 3.3.7 Set Workmode === 1033 1033 1034 1034 ... ... @@ -1053,6 +1053,8 @@ 1053 1053 * Example 1: Downlink Payload: 0A01 **~-~-->** AT+MOD=1 1054 1054 * Example 2: Downlink Payload: 0A04 **~-~-->** AT+MOD=4 1055 1055 1071 + 1072 + 1056 1056 = 4. Battery & Power Consumption = 1057 1057 1058 1058 ... ... @@ -1078,6 +1078,8 @@ 1078 1078 * (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 1079 1079 * Update through UART TTL interface.**[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 1080 1080 1098 + 1099 + 1081 1081 = 6. FAQ = 1082 1082 1083 1083 == 6.1 Where can i find source code of SN50v3-LB? == ... ... @@ -1086,6 +1086,8 @@ 1086 1086 * **[[Hardware Source Files>>https://github.com/dragino/Lora/tree/master/LSN50/v3.0]].** 1087 1087 * **[[Software Source Code & Compile instruction>>https://github.com/dragino/SN50v3]].** 1088 1088 1108 + 1109 + 1089 1089 = 7. Order Info = 1090 1090 1091 1091 ... ... @@ -1109,6 +1109,8 @@ 1109 1109 * (% style="color:red" %)**20**(%%): With M20 waterproof cable hole 1110 1110 * (% style="color:red" %)**NH**(%%): No Hole 1111 1111 1133 + 1134 + 1112 1112 = 8. Packing Info = 1113 1113 1114 1114 ... ... @@ -1123,6 +1123,8 @@ 1123 1123 * Package Size / pcs : cm 1124 1124 * Weight / pcs : g 1125 1125 1149 + 1150 + 1126 1126 = 9. Support = 1127 1127 1128 1128