Changes for page SN50v3-LB/LS -- LoRaWAN Sensor Node User Manual
Last modified by Bei Jinggeng on 2025/01/10 15:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -233,33 +233,33 @@ 233 233 234 234 (% style="color:#037691" %)**Frequency Band**: 235 235 236 - *0x01: EU868236 +0x01: EU868 237 237 238 - *0x02: US915238 +0x02: US915 239 239 240 - *0x03: IN865240 +0x03: IN865 241 241 242 - *0x04: AU915242 +0x04: AU915 243 243 244 - *0x05: KZ865244 +0x05: KZ865 245 245 246 - *0x06: RU864246 +0x06: RU864 247 247 248 - *0x07: AS923248 +0x07: AS923 249 249 250 - *0x08: AS923-1250 +0x08: AS923-1 251 251 252 - *0x09: AS923-2252 +0x09: AS923-2 253 253 254 - *0x0a: AS923-3254 +0x0a: AS923-3 255 255 256 - *0x0b: CN470256 +0x0b: CN470 257 257 258 - *0x0c: EU433258 +0x0c: EU433 259 259 260 - *0x0d: KR920260 +0x0d: KR920 261 261 262 - *0x0e: MA869262 +0x0e: MA869 263 263 264 264 265 265 (% style="color:#037691" %)**Sub-Band**: ... ... @@ -335,9 +335,8 @@ 335 335 )))|(% style="width:189px" %)((( 336 336 Digital in(PB15) & Digital Interrupt(PA8) 337 337 )))|(% style="width:208px" %)((( 338 -Distance measure by:1) LIDAR-Lite V3HP 339 -Or 340 -2) Ultrasonic Sensor 338 +Distance measure by: 1) LIDAR-Lite V3HP 339 +Or 2) Ultrasonic Sensor 341 341 )))|(% style="width:117px" %)Reserved 342 342 343 343 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/1656324539647-568.png?rev=1.1||alt="1656324539647-568.png"]] ... ... @@ -651,9 +651,9 @@ 651 651 ==== 2.3.3.4 Analogue Digital Converter (ADC) ==== 652 652 653 653 654 -The measuring range of the ADC is only about 0V to 1.1V The voltage resolution is about 0.24mv. 653 +The measuring range of the ADC is only about 0.1V to 1.1V The voltage resolution is about 0.24mv. 655 655 656 -When the measured output voltage of the sensor is not within the range of 0V and 1.1V, the output voltage terminal of the sensor shall be divided The example in the following figure is to reduce the output voltage of the sensor by three times If it is necessary to reduce more times, calculate according to the formula in the figure and connect the corresponding resistance in series. 655 +When the measured output voltage of the sensor is not within the range of 0.1V and 1.1V, the output voltage terminal of the sensor shall be divided The example in the following figure is to reduce the output voltage of the sensor by three times If it is necessary to reduce more times, calculate according to the formula in the figure and connect the corresponding resistance in series. 657 657 658 658 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220628150112-1.png?width=285&height=241&rev=1.1||alt="image-20220628150112-1.png" height="241" width="285"]] 659 659 ... ... @@ -826,8 +826,6 @@ 826 826 * 7: MOD8 827 827 * 8: MOD9 828 828 829 - 830 - 831 831 == 2.4 Payload Decoder file == 832 832 833 833 ... ... @@ -857,8 +857,6 @@ 857 857 * AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]]. 858 858 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 859 859 860 - 861 - 862 862 == 3.2 General Commands == 863 863 864 864 ... ... @@ -906,8 +906,6 @@ 906 906 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 907 907 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 908 908 909 - 910 - 911 911 === 3.3.2 Get Device Status === 912 912 913 913 ... ... @@ -956,8 +956,6 @@ 956 956 * Example 3: Downlink Payload: 06000102 **~-~-->** AT+INTMOD2=2 957 957 * Example 4: Downlink Payload: 06000201 **~-~-->** AT+INTMOD3=1 958 958 959 - 960 - 961 961 === 3.3.4 Set Power Output Duration === 962 962 963 963 ... ... @@ -990,8 +990,6 @@ 990 990 * Example 1: Downlink Payload: 070000 **~-~-->** AT+5VT=0 991 991 * Example 2: Downlink Payload: 0701F4 **~-~-->** AT+5VT=500 992 992 993 - 994 - 995 995 === 3.3.5 Set Weighing parameters === 996 996 997 997 ... ... @@ -1017,8 +1017,6 @@ 1017 1017 * Example 2: Downlink Payload: 08020FA3 **~-~-->** AT+WEIGAP=400.3 1018 1018 * Example 3: Downlink Payload: 08020FA0 **~-~-->** AT+WEIGAP=400.0 1019 1019 1020 - 1021 - 1022 1022 === 3.3.6 Set Digital pulse count value === 1023 1023 1024 1024 ... ... @@ -1042,8 +1042,6 @@ 1042 1042 * Example 1: Downlink Payload: 090100000000 **~-~-->** AT+SETCNT=1,0 1043 1043 * Example 2: Downlink Payload: 0902000003E8 **~-~-->** AT+SETCNT=2,1000 1044 1044 1045 - 1046 - 1047 1047 === 3.3.7 Set Workmode === 1048 1048 1049 1049 ... ... @@ -1068,8 +1068,6 @@ 1068 1068 * Example 1: Downlink Payload: 0A01 **~-~-->** AT+MOD=1 1069 1069 * Example 2: Downlink Payload: 0A04 **~-~-->** AT+MOD=4 1070 1070 1071 - 1072 - 1073 1073 = 4. Battery & Power Consumption = 1074 1074 1075 1075 ... ... @@ -1095,8 +1095,6 @@ 1095 1095 * (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 1096 1096 * Update through UART TTL interface.**[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 1097 1097 1098 - 1099 - 1100 1100 = 6. FAQ = 1101 1101 1102 1102 == 6.1 Where can i find source code of SN50v3-LB? == ... ... @@ -1105,8 +1105,6 @@ 1105 1105 * **[[Hardware Source Files>>https://github.com/dragino/Lora/tree/master/LSN50/v3.0]].** 1106 1106 * **[[Software Source Code & Compile instruction>>https://github.com/dragino/SN50v3]].** 1107 1107 1108 - 1109 - 1110 1110 = 7. Order Info = 1111 1111 1112 1112 ... ... @@ -1130,8 +1130,6 @@ 1130 1130 * (% style="color:red" %)**20**(%%): With M20 waterproof cable hole 1131 1131 * (% style="color:red" %)**NH**(%%): No Hole 1132 1132 1133 - 1134 - 1135 1135 = 8. Packing Info = 1136 1136 1137 1137 ... ... @@ -1146,8 +1146,6 @@ 1146 1146 * Package Size / pcs : cm 1147 1147 * Weight / pcs : g 1148 1148 1149 - 1150 - 1151 1151 = 9. Support = 1152 1152 1153 1153