... ... @@ -776,7 +776,7 @@
776 776  
777 777  The 5V output time can be controlled by AT Command.
778 778  
779 -(% style="color:blue" %)**AT+5VT=1000**
779 +**AT+5VT=1000**
780 780  
781 781  Means set 5V valid time to have 1000ms. So the real 5V output will actually have 1000ms + sampling time for other sensors.
782 782  
... ... @@ -811,8 +811,8 @@
811 811  * 7: MOD8
812 812  * 8: MOD9
813 813  
814 +== ==
814 814  
815 -
816 816  == 2.4 Payload Decoder file ==
817 817  
818 818  
... ... @@ -889,8 +889,8 @@
889 889  * Example 1: Downlink Payload: 0100001E  ~/~/  Set Transmit Interval (TDC) = 30 seconds
890 890  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
891 891  
892 +=== ===
892 892  
893 -
894 894  === 3.3.2 Get Device Status ===
895 895  
896 896  Send a LoRaWAN downlink to ask the device to send its status.
... ... @@ -938,8 +938,8 @@
938 938  * Example 3: Downlink Payload: 06000102  **~-~-->**  AT+INTMOD2=2
939 939  * Example 4: Downlink Payload: 06000201  **~-~-->**  AT+INTMOD3=1
940 940  
941 +=== ===
941 941  
942 -
943 943  === 3.3.4 Set Power Output Duration ===
944 944  
945 945  Control the output duration 5V . Before each sampling, device will
... ... @@ -956,6 +956,7 @@
956 956  |=(% style="width: 154px;background-color:#D9E2F3" %)**Command Example**|=(% style="width: 196px;background-color:#D9E2F3" %)**Function**|=(% style="width: 157px;background-color:#D9E2F3" %)**Response**
957 957  |(% style="width:154px" %)AT+5VT=?|(% style="width:196px" %)Show 5V open time.|(% style="width:157px" %)(((
958 958  500(default)
959 +
959 959  OK
960 960  )))
961 961  |(% style="width:154px" %)AT+5VT=1000|(% style="width:196px" %)(((
... ... @@ -971,8 +971,8 @@
971 971  * Example 1: Downlink Payload: 070000  **~-~-->**  AT+5VT=0
972 972  * Example 2: Downlink Payload: 0701F4  **~-~-->**  AT+5VT=500
973 973  
975 +=== ===
974 974  
975 -
976 976  === 3.3.5 Set Weighing parameters ===
977 977  
978 978  Feature: Working mode 5 is effective, weight initialization and weight factor setting of HX711.
... ... @@ -997,8 +997,8 @@
997 997  * Example 2: Downlink Payload: 08020FA3  **~-~-->**  AT+WEIGAP=400.3
998 998  * Example 3: Downlink Payload: 08020FA0  **~-~-->**  AT+WEIGAP=400.0
999 999  
1001 +=== ===
1000 1000  
1001 -
1002 1002  === 3.3.6 Set Digital pulse count value ===
1003 1003  
1004 1004  Feature: Set the pulse count value.
... ... @@ -1021,8 +1021,8 @@
1021 1021  * Example 1: Downlink Payload: 090100000000  **~-~-->**  AT+SETCNT=1,0
1022 1022  * Example 2: Downlink Payload: 0902000003E8  **~-~-->**  AT+SETCNT=2,1000
1023 1023  
1025 +=== ===
1024 1024  
1025 -
1026 1026  === 3.3.7 Set Workmode ===
1027 1027  
1028 1028  Feature: Switch working mode.
... ... @@ -1036,6 +1036,7 @@
1036 1036  )))
1037 1037  |(% style="width:154px" %)AT+MOD=4|(% style="width:196px" %)Set the working mode to 3DS18B20s.|(% style="width:157px" %)(((
1038 1038  OK
1040 +
1039 1039  Attention:Take effect after ATZ
1040 1040  )))
1041 1041  
... ... @@ -1046,8 +1046,8 @@
1046 1046  * Example 1: Downlink Payload: 0A01  **~-~-->**  AT+MOD=1
1047 1047  * Example 2: Downlink Payload: 0A04  **~-~-->**  AT+MOD=4
1048 1048  
1051 += =
1049 1049  
1050 -
1051 1051  = 4. Battery & Power Consumption =
1052 1052  
1053 1053  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved