Changes for page SN50v3-LB/LS -- LoRaWAN Sensor Node User Manual
Last modified by Bei Jinggeng on 2025/01/10 15:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -776,7 +776,7 @@ 776 776 777 777 The 5V output time can be controlled by AT Command. 778 778 779 -**AT+5VT=1000** 779 +(% style="color:blue" %)**AT+5VT=1000** 780 780 781 781 Means set 5V valid time to have 1000ms. So the real 5V output will actually have 1000ms + sampling time for other sensors. 782 782 ... ... @@ -811,8 +811,8 @@ 811 811 * 7: MOD8 812 812 * 8: MOD9 813 813 814 -== == 815 815 815 + 816 816 == 2.4 Payload Decoder file == 817 817 818 818 ... ... @@ -889,8 +889,8 @@ 889 889 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 890 890 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 891 891 892 -=== === 893 893 893 + 894 894 === 3.3.2 Get Device Status === 895 895 896 896 Send a LoRaWAN downlink to ask the device to send its status. ... ... @@ -938,8 +938,8 @@ 938 938 * Example 3: Downlink Payload: 06000102 **~-~-->** AT+INTMOD2=2 939 939 * Example 4: Downlink Payload: 06000201 **~-~-->** AT+INTMOD3=1 940 940 941 -=== === 942 942 942 + 943 943 === 3.3.4 Set Power Output Duration === 944 944 945 945 Control the output duration 5V . Before each sampling, device will ... ... @@ -956,7 +956,6 @@ 956 956 |=(% style="width: 154px;background-color:#D9E2F3" %)**Command Example**|=(% style="width: 196px;background-color:#D9E2F3" %)**Function**|=(% style="width: 157px;background-color:#D9E2F3" %)**Response** 957 957 |(% style="width:154px" %)AT+5VT=?|(% style="width:196px" %)Show 5V open time.|(% style="width:157px" %)((( 958 958 500(default) 959 - 960 960 OK 961 961 ))) 962 962 |(% style="width:154px" %)AT+5VT=1000|(% style="width:196px" %)((( ... ... @@ -972,8 +972,8 @@ 972 972 * Example 1: Downlink Payload: 070000 **~-~-->** AT+5VT=0 973 973 * Example 2: Downlink Payload: 0701F4 **~-~-->** AT+5VT=500 974 974 975 -=== === 976 976 975 + 977 977 === 3.3.5 Set Weighing parameters === 978 978 979 979 Feature: Working mode 5 is effective, weight initialization and weight factor setting of HX711. ... ... @@ -998,8 +998,8 @@ 998 998 * Example 2: Downlink Payload: 08020FA3 **~-~-->** AT+WEIGAP=400.3 999 999 * Example 3: Downlink Payload: 08020FA0 **~-~-->** AT+WEIGAP=400.0 1000 1000 1001 -=== === 1002 1002 1001 + 1003 1003 === 3.3.6 Set Digital pulse count value === 1004 1004 1005 1005 Feature: Set the pulse count value. ... ... @@ -1022,8 +1022,8 @@ 1022 1022 * Example 1: Downlink Payload: 090100000000 **~-~-->** AT+SETCNT=1,0 1023 1023 * Example 2: Downlink Payload: 0902000003E8 **~-~-->** AT+SETCNT=2,1000 1024 1024 1025 -=== === 1026 1026 1025 + 1027 1027 === 3.3.7 Set Workmode === 1028 1028 1029 1029 Feature: Switch working mode. ... ... @@ -1037,7 +1037,6 @@ 1037 1037 ))) 1038 1038 |(% style="width:154px" %)AT+MOD=4|(% style="width:196px" %)Set the working mode to 3DS18B20s.|(% style="width:157px" %)((( 1039 1039 OK 1040 - 1041 1041 Attention:Take effect after ATZ 1042 1042 ))) 1043 1043 ... ... @@ -1048,8 +1048,8 @@ 1048 1048 * Example 1: Downlink Payload: 0A01 **~-~-->** AT+MOD=1 1049 1049 * Example 2: Downlink Payload: 0A04 **~-~-->** AT+MOD=4 1050 1050 1051 -= = 1052 1052 1050 + 1053 1053 = 4. Battery & Power Consumption = 1054 1054 1055 1055