Changes for page SN50v3-LB/LS -- LoRaWAN Sensor Node User Manual
Last modified by Bei Jinggeng on 2025/01/10 15:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -41,8 +41,6 @@ 41 41 * Downlink to change configure 42 42 * 8500mAh Battery for long term use 43 43 44 - 45 - 46 46 == 1.3 Specification == 47 47 48 48 ... ... @@ -80,8 +80,6 @@ 80 80 * Sleep Mode: 5uA @ 3.3v 81 81 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 82 82 83 - 84 - 85 85 == 1.4 Sleep mode and working mode == 86 86 87 87 ... ... @@ -109,8 +109,6 @@ 109 109 ))) 110 110 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode. 111 111 112 - 113 - 114 114 == 1.6 BLE connection == 115 115 116 116 ... ... @@ -283,21 +283,22 @@ 283 283 === 2.3.2 Working Modes & Sensor Data. Uplink via FPORT~=2 === 284 284 285 285 286 -SN50v3 has different working mode for the connections of different type of sensors. This section describes these modes. Use can use the AT Command AT+MOD to set SN50v3 to different working modes. 280 +SN50v3-LB has different working mode for the connections of different type of sensors. This section describes these modes. Use can use the AT Command (% style="color:blue" %)**AT+MOD**(%%) to set SN50v3-LB to different working modes. 287 287 288 288 For example: 289 289 290 - **AT+MOD=2 ** ~/~/ will set the SN50v3 to work in MOD=2 distance mode which target to measure distance via Ultrasonic Sensor. 284 + (% style="color:blue" %)**AT+MOD=2 ** (%%) ~/~/ will set the SN50v3 to work in MOD=2 distance mode which target to measure distance via Ultrasonic Sensor. 291 291 292 292 293 293 (% style="color:red" %) **Important Notice:** 294 294 295 -1. Some working modes has payload more than 12 bytes, The US915/AU915/AS923 frequency bands' definition has maximum 11 bytes in **DR0**. Server sides will see NULL payload while SN50v3 transmit in DR0 with 12 bytes payload. 296 -1. All modes share the same Payload Explanation from HERE. 297 -1. By default, the device will send an uplink message every 20 minutes. 289 +~1. Some working modes has payload more than 12 bytes, The US915/AU915/AS923 frequency bands' definition has maximum 11 bytes in (% style="color:blue" %)**DR0**(%%). Server sides will see NULL payload while SN50v3 transmit in DR0 with 12 bytes payload. 298 298 291 +2. All modes share the same Payload Explanation from HERE. 299 299 293 +3. By default, the device will send an uplink message every 20 minutes. 300 300 295 + 301 301 ==== 2.3.2.1 MOD~=1 (Default Mode) ==== 302 302 303 303 ... ... @@ -350,7 +350,7 @@ 350 350 351 351 (% style="color:blue" %)**Connection to Ultrasonic Sensor:** 352 352 353 -Need to remove R1 and R2 resistors to get low power,otherwise there will be 240uA standby current. 348 +(% style="color:red" %)**Need to remove R1 and R2 resistors to get low power,otherwise there will be 240uA standby current.** 354 354 355 355 [[image:image-20230512173903-6.png||height="596" width="715"]] 356 356 ... ... @@ -376,7 +376,7 @@ 376 376 377 377 **Connection to [[TF-Mini plus>>url:http://en.benewake.com/product/detail/5c345cd0e5b3a844c472329b.html]] LiDAR(UART version):** 378 378 379 -Need to remove R3 and R4 resistors to get low power,otherwise there will be 400uA standby current. 374 +(% style="color:red" %)**Need to remove R3 and R4 resistors to get low power,otherwise there will be 400uA standby current.** 380 380 381 381 [[image:image-20230512180609-7.png||height="555" width="802"]] 382 382 ... ... @@ -383,7 +383,7 @@ 383 383 384 384 **Connection to [[TF-Luna>>url:http://en.benewake.com/product/detail/5e1c1fd04d839408076b6255.html]] LiDAR (UART version):** 385 385 386 -Need to remove R3 and R4 resistors to get low power,otherwise there will be 400uA standby current. 381 +(% style="color:red" %)**Need to remove R3 and R4 resistors to get low power,otherwise there will be 400uA standby current.** 387 387 388 388 [[image:image-20230513105207-4.png||height="469" width="802"]] 389 389 ... ... @@ -443,8 +443,8 @@ 443 443 444 444 Each HX711 need to be calibrated before used. User need to do below two steps: 445 445 446 -1. Zero calibration. Don't put anything on load cell and run **AT+WEIGRE** to calibrate to Zero gram. 447 -1. Adjust calibration factor (default value 400): Put a known weight thing on load cell and run **AT+WEIGAP** to adjust the Calibration Factor. 441 +1. Zero calibration. Don't put anything on load cell and run (% style="color:blue" %)**AT+WEIGRE**(%%) to calibrate to Zero gram. 442 +1. Adjust calibration factor (default value 400): Put a known weight thing on load cell and run (% style="color:blue" %)**AT+WEIGAP**(%%) to adjust the Calibration Factor. 448 448 1. ((( 449 449 Weight has 4 bytes, the unit is g. 450 450 ... ... @@ -454,7 +454,7 @@ 454 454 455 455 For example: 456 456 457 -**AT+GETSENSORVALUE =0** 452 +(% style="color:blue" %)**AT+GETSENSORVALUE =0** 458 458 459 459 Response: Weight is 401 g 460 460 ... ... @@ -598,13 +598,13 @@ 598 598 599 599 The payload decoder function for TTN V3 are here: 600 600 601 -SN50v3 TTN V3 Payload Decoder: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>url:https://github.com/dragino/dragino-end-node-decoder]] 596 +SN50v3-LB TTN V3 Payload Decoder: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>url:https://github.com/dragino/dragino-end-node-decoder]] 602 602 603 603 604 604 ==== 2.3.3.1 Battery Info ==== 605 605 606 606 607 -Check the battery voltage for SN50v3. 602 +Check the battery voltage for SN50v3-LB. 608 608 609 609 Ex1: 0x0B45 = 2885mV 610 610 ... ... @@ -658,6 +658,7 @@ 658 658 659 659 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220628150112-1.png?width=285&height=241&rev=1.1||alt="image-20220628150112-1.png" height="241" width="285"]] 660 660 656 + 661 661 (% style="color:red" %)**Note: If the ADC type sensor needs to be powered by SN50_v3, it is recommended to use +5V to control its switch.Only sensors with low power consumption can be powered with VDD.** 662 662 663 663 ... ... @@ -664,7 +664,7 @@ 664 664 ==== 2.3.3.5 Digital Interrupt ==== 665 665 666 666 667 -Digital Interrupt refers to pin PA8, and there are different trigger methods. When there is a trigger, the SN50v3 will send a packet to the server. 663 +Digital Interrupt refers to pin PA8, and there are different trigger methods. When there is a trigger, the SN50v3-LB will send a packet to the server. 668 668 669 669 (% style="color:blue" %)** Interrupt connection method:** 670 670 ... ... @@ -677,18 +677,18 @@ 677 677 678 678 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/1656379210849-860.png?rev=1.1||alt="1656379210849-860.png"]] 679 679 680 -When the two pieces are close to each other, the 2 wire output will be short or open (depending on the type), while if the two pieces are away from each other, the 2 wire output will be the opposite status. So we can use SN50 _v3 interrupt interface to detect the status for the door or window.676 +When the two pieces are close to each other, the 2 wire output will be short or open (depending on the type), while if the two pieces are away from each other, the 2 wire output will be the opposite status. So we can use SN50v3-LB interrupt interface to detect the status for the door or window. 681 681 682 682 683 683 (% style="color:blue" %)**Below is the installation example:** 684 684 685 -Fix one piece of the magnetic sensor to the door and connect the two pins to SN50 _v3 as follows:681 +Fix one piece of the magnetic sensor to the door and connect the two pins to SN50v3-LB as follows: 686 686 687 687 * ((( 688 -One pin to SN50 _v3's PA8 pin684 +One pin to SN50v3-LB's PA8 pin 689 689 ))) 690 690 * ((( 691 -The other pin to SN50 _v3's VDD pin687 +The other pin to SN50v3-LB's VDD pin 692 692 ))) 693 693 694 694 Install the other piece to the door. Find a place where the two pieces will be close to each other when the door is closed. For this particular magnetic sensor, when the door is closed, the output will be short, and PA8 will be at the VCC voltage. ... ... @@ -705,7 +705,7 @@ 705 705 706 706 The command is: 707 707 708 -(% style="color:blue" %)**AT+INTMOD1=1 ** (%%) ~/~/(more info about INMOD please refer** **[[**AT Command Manual**>>url:http://www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/&file=DRAGINO_LSN50_AT_Commands_v1.5.1.pdf]]**. **) 704 +(% style="color:blue" %)**AT+INTMOD1=1 ** (%%) ~/~/ (more info about INMOD please refer** **[[**AT Command Manual**>>url:http://www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/&file=DRAGINO_LSN50_AT_Commands_v1.5.1.pdf]]**. **) 709 709 710 710 Below shows some screen captures in TTN V3: 711 711 ... ... @@ -724,11 +724,11 @@ 724 724 725 725 We have made an example to show how to use the I2C interface to connect to the SHT20/ SHT31 Temperature and Humidity Sensor. 726 726 727 -Notice: Different I2C sensors have different I2C commands set and initiate process, if user want to use other I2C sensors, User need to re-write the source code to support those sensors. SHT20/ SHT31 code in SN50 _v3 will be a good reference.723 +(% style="color:red" %)**Notice: Different I2C sensors have different I2C commands set and initiate process, if user want to use other I2C sensors, User need to re-write the source code to support those sensors. SHT20/ SHT31 code in SN50v3-LB will be a good reference.** 728 728 725 + 729 729 Below is the connection to SHT20/ SHT31. The connection is as below: 730 730 731 - 732 732 [[image:image-20230513103633-3.png||height="448" width="716"]] 733 733 734 734 The device will be able to get the I2C sensor data now and upload to IoT Server. ... ... @@ -757,7 +757,7 @@ 757 757 758 758 This Fundamental Principles of this sensor can be found at this link: [[https:~~/~~/wiki.dfrobot.com/Weather_-_proof_Ultrasonic_Sensor_with_Separate_Probe_SKU~~_~~__SEN0208>>url:https://wiki.dfrobot.com/Weather_-_proof_Ultrasonic_Sensor_with_Separate_Probe_SKU___SEN0208]] 759 759 760 -The SN50 _v3 detects the pulse width of the sensor and converts it to mm output. The accuracy will be within 1 centimeter. The usable range (the distance between the ultrasonic probe and the measured object) is between 24cm and 600cm.756 +The SN50v3-LB detects the pulse width of the sensor and converts it to mm output. The accuracy will be within 1 centimeter. The usable range (the distance between the ultrasonic probe and the measured object) is between 24cm and 600cm. 761 761 762 762 The working principle of this sensor is similar to the (% style="color:blue" %)**HC-SR04**(%%) ultrasonic sensor. 763 763 ... ... @@ -766,7 +766,7 @@ 766 766 [[image:image-20230512173903-6.png||height="596" width="715"]] 767 767 768 768 769 -Connect to the SN50 _v3 and run (% style="color:blue" %)**AT+MOD=2**(%%) to switch to ultrasonic mode (ULT).765 +Connect to the SN50v3-LB and run (% style="color:blue" %)**AT+MOD=2**(%%) to switch to ultrasonic mode (ULT). 770 770 771 771 The ultrasonic sensor uses the 8^^th^^ and 9^^th^^ byte for the measurement value. 772 772 ... ... @@ -784,7 +784,7 @@ 784 784 ==== 2.3.3.10 +5V Output ==== 785 785 786 786 787 -SN50v3 will enable +5V output before all sampling and disable the +5v after all sampling. 783 +SN50v3-LB will enable +5V output before all sampling and disable the +5v after all sampling. 788 788 789 789 The 5V output time can be controlled by AT Command. 790 790 ... ... @@ -825,7 +825,6 @@ 825 825 * 7: MOD8 826 826 * 8: MOD9 827 827 828 - 829 829 == 2.4 Payload Decoder file == 830 830 831 831 ... ... @@ -855,7 +855,6 @@ 855 855 * AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]]. 856 856 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 857 857 858 - 859 859 == 3.2 General Commands == 860 860 861 861 ... ... @@ -872,7 +872,7 @@ 872 872 == 3.3 Commands special design for SN50v3-LB == 873 873 874 874 875 -These commands only valid for S3 1x-LB, as below:869 +These commands only valid for SN50v3-LB, as below: 876 876 877 877 878 878 === 3.3.1 Set Transmit Interval Time === ... ... @@ -903,7 +903,6 @@ 903 903 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 904 904 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 905 905 906 - 907 907 === 3.3.2 Get Device Status === 908 908 909 909 ... ... @@ -952,7 +952,6 @@ 952 952 * Example 3: Downlink Payload: 06000102 **~-~-->** AT+INTMOD2=2 953 953 * Example 4: Downlink Payload: 06000201 **~-~-->** AT+INTMOD3=1 954 954 955 - 956 956 === 3.3.4 Set Power Output Duration === 957 957 958 958 ... ... @@ -985,7 +985,6 @@ 985 985 * Example 1: Downlink Payload: 070000 **~-~-->** AT+5VT=0 986 986 * Example 2: Downlink Payload: 0701F4 **~-~-->** AT+5VT=500 987 987 988 - 989 989 === 3.3.5 Set Weighing parameters === 990 990 991 991 ... ... @@ -1011,7 +1011,6 @@ 1011 1011 * Example 2: Downlink Payload: 08020FA3 **~-~-->** AT+WEIGAP=400.3 1012 1012 * Example 3: Downlink Payload: 08020FA0 **~-~-->** AT+WEIGAP=400.0 1013 1013 1014 - 1015 1015 === 3.3.6 Set Digital pulse count value === 1016 1016 1017 1017 ... ... @@ -1035,7 +1035,6 @@ 1035 1035 * Example 1: Downlink Payload: 090100000000 **~-~-->** AT+SETCNT=1,0 1036 1036 * Example 2: Downlink Payload: 0902000003E8 **~-~-->** AT+SETCNT=2,1000 1037 1037 1038 - 1039 1039 === 3.3.7 Set Workmode === 1040 1040 1041 1041 ... ... @@ -1060,7 +1060,6 @@ 1060 1060 * Example 1: Downlink Payload: 0A01 **~-~-->** AT+MOD=1 1061 1061 * Example 2: Downlink Payload: 0A04 **~-~-->** AT+MOD=4 1062 1062 1063 - 1064 1064 = 4. Battery & Power Consumption = 1065 1065 1066 1066 ... ... @@ -1087,7 +1087,6 @@ 1087 1087 * (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 1088 1088 * Update through UART TTL interface.**[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 1089 1089 1090 - 1091 1091 = 6. FAQ = 1092 1092 1093 1093 == 6.1 Where can i find source code of SN50v3-LB? == ... ... @@ -1096,7 +1096,6 @@ 1096 1096 * **[[Hardware Source Files>>https://github.com/dragino/Lora/tree/master/LSN50/v3.0]].** 1097 1097 * **[[Software Source Code & Compile instruction>>https://github.com/dragino/SN50v3]].** 1098 1098 1099 - 1100 1100 = 7. Order Info = 1101 1101 1102 1102 ... ... @@ -1120,7 +1120,6 @@ 1120 1120 * (% style="color:red" %)**20**(%%): With M20 waterproof cable hole 1121 1121 * (% style="color:red" %)**NH**(%%): No Hole 1122 1122 1123 - 1124 1124 = 8. Packing Info = 1125 1125 1126 1126 ... ... @@ -1135,7 +1135,6 @@ 1135 1135 * Package Size / pcs : cm 1136 1136 * Weight / pcs : g 1137 1137 1138 - 1139 1139 = 9. Support = 1140 1140 1141 1141