From version < 43.4 >
edited by Xiaoling
on 2023/05/16 13:41
To version < 43.11 >
edited by Xiaoling
on 2023/05/16 13:58
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -291,31 +291,25 @@
291 291  
292 292  ==== 2.3.2.1  MOD~=1 (Default Mode) ====
293 293  
294 +
294 294  In this mode, uplink payload includes in total 11 bytes. Uplink packets use FPORT=2.
295 295  
296 -(% style="width:1110px" %)
297 -|**Size(bytes)**|**2**|(% style="width:191px" %)**2**|(% style="width:78px" %)**2**|(% style="width:216px" %)**1**|(% style="width:308px" %)**2**|(% style="width:154px" %)**2**
297 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
298 +|(% style="width:50px;background-color:#D9E2F3;color:#0070C0" %)**Size(bytes)**|(% style="width:20px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:80px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:40px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:100px;background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="width:130px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:100px;background-color:#D9E2F3;color:#0070C0" %)**2**
298 298  |**Value**|Bat|(% style="width:191px" %)(((
299 299  Temperature(DS18B20)
300 -
301 301  (PC13)
302 302  )))|(% style="width:78px" %)(((
303 303  ADC
304 -
305 305  (PA4)
306 306  )))|(% style="width:216px" %)(((
307 307  Digital in(PB15) &
308 -
309 -Digital Interrupt(PA8)
310 -
311 -
307 +Digital Interrupt(PA8)
312 312  )))|(% style="width:308px" %)(((
313 313  Temperature
314 -
315 315  (SHT20 or SHT31 or BH1750 Illumination Sensor)
316 316  )))|(% style="width:154px" %)(((
317 317  Humidity
318 -
319 319  (SHT20 or SHT31)
320 320  )))
321 321  
... ... @@ -330,15 +330,12 @@
330 330  |**Size(bytes)**|**2**|(% style="width:196px" %)**2**|(% style="width:87px" %)**2**|(% style="width:189px" %)**1**|(% style="width:208px" %)**2**|(% style="width:117px" %)**2**
331 331  |**Value**|BAT|(% style="width:196px" %)(((
332 332  Temperature(DS18B20)
333 -
334 334  (PC13)
335 335  )))|(% style="width:87px" %)(((
336 336  ADC
337 -
338 338  (PA4)
339 339  )))|(% style="width:189px" %)(((
340 340  Digital in(PB15) &
341 -
342 342  Digital Interrupt(PA8)
343 343  )))|(% style="width:208px" %)(((
344 344  Distance measure by:
... ... @@ -365,15 +365,12 @@
365 365  |**Size(bytes)**|**2**|(% style="width:183px" %)**2**|(% style="width:173px" %)**1**|(% style="width:84px" %)**2**|(% style="width:323px" %)**2**|(% style="width:188px" %)**2**
366 366  |**Value**|BAT|(% style="width:183px" %)(((
367 367  Temperature(DS18B20)
368 -
369 369  (PC13)
370 370  )))|(% style="width:173px" %)(((
371 371  Digital in(PB15) &
372 -
373 373  Digital Interrupt(PA8)
374 374  )))|(% style="width:84px" %)(((
375 375  ADC
376 -
377 377  (PA4)
378 378  )))|(% style="width:323px" %)(((
379 379  Distance measure by:1)TF-Mini plus LiDAR
... ... @@ -406,25 +406,20 @@
406 406  )))|=(% style="width: 68px;" %)**2**|=(% style="width: 75px;" %)**2**|=**2**|=**1**|=(% style="width: 304px;" %)2|=(% style="width: 163px;" %)2|=(% style="width: 53px;" %)1
407 407  |**Value**|(% style="width:68px" %)(((
408 408  ADC1
409 -
410 410  (PA4)
411 411  )))|(% style="width:75px" %)(((
412 412  ADC2
413 -
414 414  (PA5)
415 415  )))|(((
416 416  ADC3
417 -
418 418  (PA8)
419 419  )))|(((
420 420  Digital Interrupt(PB15)
421 421  )))|(% style="width:304px" %)(((
422 422  Temperature
423 -
424 424  (SHT20 or SHT31 or BH1750 Illumination Sensor)
425 425  )))|(% style="width:163px" %)(((
426 426  Humidity
427 -
428 428  (SHT20 or SHT31)
429 429  )))|(% style="width:53px" %)Bat
430 430  
... ... @@ -443,11 +443,9 @@
443 443  (PC13)
444 444  )))|(% style="width:82px" %)(((
445 445  ADC
446 -
447 447  (PA4)
448 448  )))|(% style="width:210px" %)(((
449 449  Digital in(PB15) &
450 -
451 451  Digital Interrupt(PA8) 
452 452  )))|(% style="width:191px" %)Temperature2(DS18B20)
453 453  (PB9)|(% style="width:183px" %)Temperature3(DS18B20)
... ... @@ -484,17 +484,12 @@
484 484  )))|=**2**|=(% style="width: 193px;" %)**2**|=(% style="width: 85px;" %)**2**|=(% style="width: 186px;" %)**1**|=(% style="width: 100px;" %)**4**
485 485  |**Value**|BAT|(% style="width:193px" %)(((
486 486  Temperature(DS18B20)
487 -
488 488  (PC13)
489 -
490 -
491 491  )))|(% style="width:85px" %)(((
492 492  ADC
493 -
494 494  (PA4)
495 495  )))|(% style="width:186px" %)(((
496 496  Digital in(PB15) &
497 -
498 498  Digital Interrupt(PA8)
499 499  )))|(% style="width:100px" %)Weight
500 500  
... ... @@ -519,15 +519,12 @@
519 519  (PC13)
520 520  )))|(% style="width:108px" %)(((
521 521  ADC
522 -
523 523  (PA4)
524 524  )))|(% style="width:126px" %)(((
525 525  Digital in
526 -
527 527  (PB15)
528 528  )))|(% style="width:145px" %)(((
529 529  Count
530 -
531 531  (PA8)
532 532  )))
533 533  
... ... @@ -542,11 +542,9 @@
542 542  )))|=**2**|=(% style="width: 188px;" %)**2**|=(% style="width: 83px;" %)**2**|=(% style="width: 184px;" %)**1**|=(% style="width: 186px;" %)**1**|=(% style="width: 197px;" %)1|=(% style="width: 100px;" %)2
543 543  |**Value**|BAT|(% style="width:188px" %)(((
544 544  Temperature(DS18B20)
545 -
546 546  (PC13)
547 547  )))|(% style="width:83px" %)(((
548 548  ADC
549 -
550 550  (PA5)
551 551  )))|(% style="width:184px" %)(((
552 552  Digital Interrupt1(PA8)
... ... @@ -562,21 +562,17 @@
562 562  )))|=**2**|=(% style="width: 207px;" %)**2**|=(% style="width: 94px;" %)**2**|=(% style="width: 198px;" %)**1**|=(% style="width: 84px;" %)**2**|=(% style="width: 82px;" %)2
563 563  |**Value**|BAT|(% style="width:207px" %)(((
564 564  Temperature(DS18B20)
565 -
566 566  (PC13)
567 567  )))|(% style="width:94px" %)(((
568 568  ADC1
569 -
570 570  (PA4)
571 571  )))|(% style="width:198px" %)(((
572 572  Digital Interrupt(PB15)
573 573  )))|(% style="width:84px" %)(((
574 574  ADC2
575 -
576 576  (PA5)
577 577  )))|(% style="width:82px" %)(((
578 578  ADC3
579 -
580 580  (PA8)
581 581  )))
582 582  
... ... @@ -591,27 +591,21 @@
591 591  )))|=**2**|=**2**|=**2**|=**1**|=(% style="width: 193px;" %)**2**|=(% style="width: 78px;" %)4|=(% style="width: 78px;" %)4
592 592  |**Value**|BAT|(((
593 593  Temperature1(DS18B20)
594 -
595 595  (PC13)
596 596  )))|(((
597 597  Temperature2(DS18B20)
598 -
599 599  (PB9)
600 600  )))|(((
601 601  Digital Interrupt
602 -
603 603  (PB15)
604 604  )))|(% style="width:193px" %)(((
605 605  Temperature3(DS18B20)
606 -
607 607  (PB8)
608 608  )))|(% style="width:78px" %)(((
609 609  Count1
610 -
611 611  (PA8)
612 612  )))|(% style="width:78px" %)(((
613 613  Count2
614 -
615 615  (PA4)
616 616  )))
617 617  
... ... @@ -683,9 +683,7 @@
683 683  (((
684 684  When the digital interrupt pin is set to AT+INTMODx=0, this pin is used as a digital input pin.
685 685  
686 -**Note:**The maximum voltage input supports 3.6V.
687 -
688 -
647 +(% style="color:red" %)**Note:**The maximum voltage input supports 3.6V.
689 689  )))
690 690  
691 691  ==== 2.3.3.4  Analogue Digital Converter (ADC) ====
... ... @@ -696,7 +696,7 @@
696 696  
697 697  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220628150112-1.png?width=285&height=241&rev=1.1||alt="image-20220628150112-1.png" height="241" width="285"]]
698 698  
699 -**Note:**If the ADC type sensor needs to be powered by SN50_v3, it is recommended to use +5V to control its switch.Only sensors with low power consumption can be powered with VDD.
658 +(% style="color:red" %)**Note:**If the ADC type sensor needs to be powered by SN50_v3, it is recommended to use +5V to control its switch.Only sensors with low power consumption can be powered with VDD.
700 700  
701 701  
702 702  ==== 2.3.3.5 Digital Interrupt ====
... ... @@ -703,11 +703,11 @@
703 703  
704 704  Digital Interrupt refers to pin PA8, and there are different trigger methods. When there is a trigger, the SN50v3 will send a packet to the server.
705 705  
706 -**~ Interrupt connection method:**
665 +(% style="color:blue" %)**~ Interrupt connection method:**
707 707  
708 708  [[image:image-20230513105351-5.png||height="147" width="485"]]
709 709  
710 -**Example to use with door sensor :**
669 +(% style="color:blue" %)**Example to use with door sensor :**
711 711  
712 712  The door sensor is shown at right. It is a two wire magnetic contact switch used for detecting the open/close status of doors or windows.
713 713  
... ... @@ -715,7 +715,7 @@
715 715  
716 716  When the two pieces are close to each other, the 2 wire output will be short or open (depending on the type), while if the two pieces are away from each other, the 2 wire output will be the opposite status. So we can use SN50_v3 interrupt interface to detect the status for the door or window.
717 717  
718 -**~ Below is the installation example:**
677 +(% style="color:blue" %)**~ Below is the installation example:**
719 719  
720 720  Fix one piece of the magnetic sensor to the door and connect the two pins to SN50_v3 as follows:
721 721  
... ... @@ -740,7 +740,7 @@
740 740  
741 741  The command is:
742 742  
743 -**AT+INTMOD1=1       **~/~/(more info about INMOD please refer** **[[**AT Command Manual**>>url:http://www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/&file=DRAGINO_LSN50_AT_Commands_v1.5.1.pdf]]**. **)
702 +(% style="color:blue" %)**AT+INTMOD1=1   ** (%%) ~/~/(more info about INMOD please refer** **[[**AT Command Manual**>>url:http://www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/&file=DRAGINO_LSN50_AT_Commands_v1.5.1.pdf]]**. **)
744 744  
745 745  Below shows some screen captures in TTN V3:
746 746  
... ... @@ -817,7 +817,7 @@
817 817  
818 818  The 5V output time can be controlled by AT Command.
819 819  
820 -**AT+5VT=1000**
779 +(% style="color:blue" %)**AT+5VT=1000**
821 821  
822 822  Means set 5V valid time to have 1000ms. So the real 5V output will actually have 1000ms + sampling time for other sensors.
823 823  
... ... @@ -852,8 +852,8 @@
852 852  * 7: MOD8
853 853  * 8: MOD9
854 854  
855 -== ==
856 856  
815 +
857 857  == 2.4 Payload Decoder file ==
858 858  
859 859  
... ... @@ -930,8 +930,8 @@
930 930  * Example 1: Downlink Payload: 0100001E  ~/~/  Set Transmit Interval (TDC) = 30 seconds
931 931  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
932 932  
933 -=== ===
934 934  
893 +
935 935  === 3.3.2 Get Device Status ===
936 936  
937 937  Send a LoRaWAN downlink to ask the device to send its status.
... ... @@ -979,8 +979,8 @@
979 979  * Example 3: Downlink Payload: 06000102  **~-~-->**  AT+INTMOD2=2
980 980  * Example 4: Downlink Payload: 06000201  **~-~-->**  AT+INTMOD3=1
981 981  
982 -=== ===
983 983  
942 +
984 984  === 3.3.4 Set Power Output Duration ===
985 985  
986 986  Control the output duration 5V . Before each sampling, device will
... ... @@ -997,7 +997,6 @@
997 997  |=(% style="width: 154px;background-color:#D9E2F3" %)**Command Example**|=(% style="width: 196px;background-color:#D9E2F3" %)**Function**|=(% style="width: 157px;background-color:#D9E2F3" %)**Response**
998 998  |(% style="width:154px" %)AT+5VT=?|(% style="width:196px" %)Show 5V open time.|(% style="width:157px" %)(((
999 999  500(default)
1000 -
1001 1001  OK
1002 1002  )))
1003 1003  |(% style="width:154px" %)AT+5VT=1000|(% style="width:196px" %)(((
... ... @@ -1013,8 +1013,8 @@
1013 1013  * Example 1: Downlink Payload: 070000  **~-~-->**  AT+5VT=0
1014 1014  * Example 2: Downlink Payload: 0701F4  **~-~-->**  AT+5VT=500
1015 1015  
1016 -=== ===
1017 1017  
975 +
1018 1018  === 3.3.5 Set Weighing parameters ===
1019 1019  
1020 1020  Feature: Working mode 5 is effective, weight initialization and weight factor setting of HX711.
... ... @@ -1039,8 +1039,8 @@
1039 1039  * Example 2: Downlink Payload: 08020FA3  **~-~-->**  AT+WEIGAP=400.3
1040 1040  * Example 3: Downlink Payload: 08020FA0  **~-~-->**  AT+WEIGAP=400.0
1041 1041  
1042 -=== ===
1043 1043  
1001 +
1044 1044  === 3.3.6 Set Digital pulse count value ===
1045 1045  
1046 1046  Feature: Set the pulse count value.
... ... @@ -1063,8 +1063,8 @@
1063 1063  * Example 1: Downlink Payload: 090100000000  **~-~-->**  AT+SETCNT=1,0
1064 1064  * Example 2: Downlink Payload: 0902000003E8  **~-~-->**  AT+SETCNT=2,1000
1065 1065  
1066 -=== ===
1067 1067  
1025 +
1068 1068  === 3.3.7 Set Workmode ===
1069 1069  
1070 1070  Feature: Switch working mode.
... ... @@ -1078,7 +1078,6 @@
1078 1078  )))
1079 1079  |(% style="width:154px" %)AT+MOD=4|(% style="width:196px" %)Set the working mode to 3DS18B20s.|(% style="width:157px" %)(((
1080 1080  OK
1081 -
1082 1082  Attention:Take effect after ATZ
1083 1083  )))
1084 1084  
... ... @@ -1089,8 +1089,8 @@
1089 1089  * Example 1: Downlink Payload: 0A01  **~-~-->**  AT+MOD=1
1090 1090  * Example 2: Downlink Payload: 0A04  **~-~-->**  AT+MOD=4
1091 1091  
1092 -= =
1093 1093  
1050 +
1094 1094  = 4. Battery & Power Consumption =
1095 1095  
1096 1096  
... ... @@ -1164,4 +1164,5 @@
1164 1164  
1165 1165  
1166 1166  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1124 +
1167 1167  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.cc>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.cc]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved