Changes for page SN50v3-LB/LS -- LoRaWAN Sensor Node User Manual
Last modified by Bei Jinggeng on 2025/01/10 15:51
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Saxer - Content
-
... ... @@ -16,15 +16,18 @@ 16 16 17 17 == 1.1 What is SN50v3-LB LoRaWAN Generic Node == 18 18 19 - 20 20 (% style="color:blue" %)**SN50V3-LB **(%%)LoRaWAN Sensor Node is a Long Range LoRa Sensor Node. It is designed for outdoor use and powered by (% style="color:blue" %)** 8500mA Li/SOCl2 battery**(%%) for long term use.SN50V3-LB is designed to facilitate developers to quickly deploy industrial level LoRa and IoT solutions. It help users to turn the idea into a practical application and make the Internet of Things a reality. It is easy to program, create and connect your things everywhere. 21 21 21 + 22 22 (% style="color:blue" %)**SN50V3-LB wireless part**(%%) is based on SX1262 allows the user to send data and reach extremely long ranges at low data-rates.It provides ultra-long range spread spectrum communication and high interference immunity whilst minimising current consumption.It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, smartphone detection, building automation, and so on. 23 23 24 + 24 24 (% style="color:blue" %)**SN50V3-LB **(%%)has a powerful 48Mhz ARM microcontroller with 256KB flash and 64KB RAM. It has multiplex I/O pins to connect to different sensors. 25 25 27 + 26 26 (% style="color:blue" %)**SN50V3-LB**(%%) has a built-in BLE module, user can configure the sensor remotely via Mobile Phone. It also support OTA upgrade via private LoRa protocol for easy maintaining. 27 27 30 + 28 28 SN50V3-LB is the 3^^rd^^ generation of LSN50 series generic sensor node from Dragino. It is an (% style="color:blue" %)**open source project**(%%) and has a mature LoRaWAN stack and application software. User can use the pre-load software for their IoT projects or easily customize the software for different requirements. 29 29 30 30 ... ... @@ -42,7 +42,6 @@ 42 42 43 43 == 1.3 Specification == 44 44 45 - 46 46 (% style="color:#037691" %)**Common DC Characteristics:** 47 47 48 48 * Supply Voltage: built in 8500mAh Li-SOCI2 battery , 2.5v ~~ 3.6v ... ... @@ -79,7 +79,6 @@ 79 79 80 80 == 1.4 Sleep mode and working mode == 81 81 82 - 83 83 (% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life. 84 84 85 85 (% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode. ... ... @@ -137,7 +137,6 @@ 137 137 138 138 == Hole Option == 139 139 140 - 141 141 SN50v3-LB has different hole size options for different size sensor cable. The options provided are M12, M16 and M20. The definition is as below: 142 142 143 143 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220627104757-1.png?rev=1.1||alt="image-20220627104757-1.png"]] ... ... @@ -291,21 +291,32 @@ 291 291 292 292 ==== 2.3.2.1 MOD~=1 (Default Mode) ==== 293 293 294 - 295 295 In this mode, uplink payload includes in total 11 bytes. Uplink packets use FPORT=2. 296 296 297 -(% border="1" cellspacing="4" style="background-color:#f2f2f2;width:520px" %)298 -| (% style="width:50px;background-color:#D9E2F3;color:#0070C0" %)**Size(bytes)**|(% style="width:20px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:100px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:40px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:90px;background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="width:130px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:90px;background-color:#D9E2F3;color:#0070C0" %)**2**296 +(% style="width:1110px" %) 297 +|**Size(bytes)**|**2**|(% style="width:191px" %)**2**|(% style="width:78px" %)**2**|(% style="width:216px" %)**1**|(% style="width:308px" %)**2**|(% style="width:154px" %)**2** 299 299 |**Value**|Bat|(% style="width:191px" %)((( 300 -Temperature(DS18B20)(PC13) 299 +Temperature(DS18B20) 300 + 301 +(PC13) 301 301 )))|(% style="width:78px" %)((( 302 -ADC(PA4) 303 +ADC 304 + 305 +(PA4) 303 303 )))|(% style="width:216px" %)((( 304 -Digital in(PB15)&Digital Interrupt(PA8) 307 +Digital in(PB15) & 308 + 309 +Digital Interrupt(PA8) 310 + 311 + 305 305 )))|(% style="width:308px" %)((( 306 -Temperature(SHT20 or SHT31 or BH1750 Illumination Sensor) 313 +Temperature 314 + 315 +(SHT20 or SHT31 or BH1750 Illumination Sensor) 307 307 )))|(% style="width:154px" %)((( 308 -Humidity(SHT20 or SHT31) 317 +Humidity 318 + 319 +(SHT20 or SHT31) 309 309 ))) 310 310 311 311 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220627150949-6.png?rev=1.1||alt="image-20220627150949-6.png"]] ... ... @@ -315,26 +315,34 @@ 315 315 316 316 This mode is target to measure the distance. The payload of this mode is totally 11 bytes. The 8^^th^^ and 9^^th^^ bytes is for the distance. 317 317 318 -(% border="1" cellspacing="4" style="background-color:#f2f2f2;width:520px" %)319 -| (% style="width:40px;background-color:#D9E2F3;color:#0070C0" %)**Size(bytes)**|(% style="width:40px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:110px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:40px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:110px;background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="width:140px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:40px;background-color:#D9E2F3;color:#0070C0" %)**2**329 +(% style="width:1011px" %) 330 +|**Size(bytes)**|**2**|(% style="width:196px" %)**2**|(% style="width:87px" %)**2**|(% style="width:189px" %)**1**|(% style="width:208px" %)**2**|(% style="width:117px" %)**2** 320 320 |**Value**|BAT|(% style="width:196px" %)((( 321 -Temperature(DS18B20)(PC13) 332 +Temperature(DS18B20) 333 + 334 +(PC13) 322 322 )))|(% style="width:87px" %)((( 323 -ADC(PA4) 336 +ADC 337 + 338 +(PA4) 324 324 )))|(% style="width:189px" %)((( 325 -Digital in(PB15) & Digital Interrupt(PA8) 340 +Digital in(PB15) & 341 + 342 +Digital Interrupt(PA8) 326 326 )))|(% style="width:208px" %)((( 327 -Distance measure by:1) LIDAR-Lite V3HP 328 -Or 2) Ultrasonic Sensor 344 +Distance measure by: 345 +1) LIDAR-Lite V3HP 346 +Or 347 +2) Ultrasonic Sensor 329 329 )))|(% style="width:117px" %)Reserved 330 330 331 331 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/1656324539647-568.png?rev=1.1||alt="1656324539647-568.png"]] 332 332 333 - (% style="color:blue" %)**Connection of LIDAR-Lite V3HP:**352 +**Connection of LIDAR-Lite V3HP:** 334 334 335 335 [[image:image-20230512173758-5.png||height="563" width="712"]] 336 336 337 - (% style="color:blue" %)**Connection to Ultrasonic Sensor:**356 +**Connection to Ultrasonic Sensor:** 338 338 339 339 Need to remove R1 and R2 resistors to get low power,otherwise there will be 240uA standby current. 340 340 ... ... @@ -342,17 +342,24 @@ 342 342 343 343 For the connection to TF-Mini or TF-Luna , MOD2 payload is as below: 344 344 345 -(% border="1" cellspacing="4" style="background-color:#f2f2f2;width:520px" %)346 -| (% style="width:50px;background-color:#D9E2F3;color:#0070C0" %)**Size(bytes)**|(% style="width:20px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:100px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:100px;background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="width:50px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:120px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:80px;background-color:#D9E2F3;color:#0070C0" %)**2**364 +(% style="width:1113px" %) 365 +|**Size(bytes)**|**2**|(% style="width:183px" %)**2**|(% style="width:173px" %)**1**|(% style="width:84px" %)**2**|(% style="width:323px" %)**2**|(% style="width:188px" %)**2** 347 347 |**Value**|BAT|(% style="width:183px" %)((( 348 -Temperature(DS18B20)(PC13) 367 +Temperature(DS18B20) 368 + 369 +(PC13) 349 349 )))|(% style="width:173px" %)((( 350 -Digital in(PB15) & Digital Interrupt(PA8) 371 +Digital in(PB15) & 372 + 373 +Digital Interrupt(PA8) 351 351 )))|(% style="width:84px" %)((( 352 -ADC(PA4) 375 +ADC 376 + 377 +(PA4) 353 353 )))|(% style="width:323px" %)((( 354 354 Distance measure by:1)TF-Mini plus LiDAR 355 -Or 2) TF-Luna LiDAR 380 +Or 381 +2) TF-Luna LiDAR 356 356 )))|(% style="width:188px" %)Distance signal strength 357 357 358 358 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/1656376779088-686.png?rev=1.1||alt="1656376779088-686.png"]] ... ... @@ -374,26 +374,31 @@ 374 374 375 375 This mode has total 12 bytes. Include 3 x ADC + 1x I2C 376 376 377 -(% border="1" cellspacing="4" style="background-color:#f2f2f2;width:520px" %)403 +(% style="width:1031px" %) 378 378 |=((( 379 - (% style="width: 50px;" %)**Size(bytes)**405 +**Size(bytes)** 380 380 )))|=(% style="width: 68px;" %)**2**|=(% style="width: 75px;" %)**2**|=**2**|=**1**|=(% style="width: 304px;" %)2|=(% style="width: 163px;" %)2|=(% style="width: 53px;" %)1 381 381 |**Value**|(% style="width:68px" %)((( 382 382 ADC1 409 + 383 383 (PA4) 384 384 )))|(% style="width:75px" %)((( 385 385 ADC2 413 + 386 386 (PA5) 387 387 )))|((( 388 388 ADC3 417 + 389 389 (PA8) 390 390 )))|((( 391 391 Digital Interrupt(PB15) 392 392 )))|(% style="width:304px" %)((( 393 393 Temperature 423 + 394 394 (SHT20 or SHT31 or BH1750 Illumination Sensor) 395 395 )))|(% style="width:163px" %)((( 396 396 Humidity 427 + 397 397 (SHT20 or SHT31) 398 398 )))|(% style="width:53px" %)Bat 399 399 ... ... @@ -412,9 +412,11 @@ 412 412 (PC13) 413 413 )))|(% style="width:82px" %)((( 414 414 ADC 446 + 415 415 (PA4) 416 416 )))|(% style="width:210px" %)((( 417 417 Digital in(PB15) & 450 + 418 418 Digital Interrupt(PA8) 419 419 )))|(% style="width:191px" %)Temperature2(DS18B20) 420 420 (PB9)|(% style="width:183px" %)Temperature3(DS18B20) ... ... @@ -451,12 +451,17 @@ 451 451 )))|=**2**|=(% style="width: 193px;" %)**2**|=(% style="width: 85px;" %)**2**|=(% style="width: 186px;" %)**1**|=(% style="width: 100px;" %)**4** 452 452 |**Value**|BAT|(% style="width:193px" %)((( 453 453 Temperature(DS18B20) 487 + 454 454 (PC13) 489 + 490 + 455 455 )))|(% style="width:85px" %)((( 456 456 ADC 493 + 457 457 (PA4) 458 458 )))|(% style="width:186px" %)((( 459 459 Digital in(PB15) & 497 + 460 460 Digital Interrupt(PA8) 461 461 )))|(% style="width:100px" %)Weight 462 462 ... ... @@ -481,12 +481,15 @@ 481 481 (PC13) 482 482 )))|(% style="width:108px" %)((( 483 483 ADC 522 + 484 484 (PA4) 485 485 )))|(% style="width:126px" %)((( 486 486 Digital in 526 + 487 487 (PB15) 488 488 )))|(% style="width:145px" %)((( 489 489 Count 530 + 490 490 (PA8) 491 491 ))) 492 492 ... ... @@ -501,9 +501,11 @@ 501 501 )))|=**2**|=(% style="width: 188px;" %)**2**|=(% style="width: 83px;" %)**2**|=(% style="width: 184px;" %)**1**|=(% style="width: 186px;" %)**1**|=(% style="width: 197px;" %)1|=(% style="width: 100px;" %)2 502 502 |**Value**|BAT|(% style="width:188px" %)((( 503 503 Temperature(DS18B20) 545 + 504 504 (PC13) 505 505 )))|(% style="width:83px" %)((( 506 506 ADC 549 + 507 507 (PA5) 508 508 )))|(% style="width:184px" %)((( 509 509 Digital Interrupt1(PA8) ... ... @@ -519,17 +519,21 @@ 519 519 )))|=**2**|=(% style="width: 207px;" %)**2**|=(% style="width: 94px;" %)**2**|=(% style="width: 198px;" %)**1**|=(% style="width: 84px;" %)**2**|=(% style="width: 82px;" %)2 520 520 |**Value**|BAT|(% style="width:207px" %)((( 521 521 Temperature(DS18B20) 565 + 522 522 (PC13) 523 523 )))|(% style="width:94px" %)((( 524 524 ADC1 569 + 525 525 (PA4) 526 526 )))|(% style="width:198px" %)((( 527 527 Digital Interrupt(PB15) 528 528 )))|(% style="width:84px" %)((( 529 529 ADC2 575 + 530 530 (PA5) 531 531 )))|(% style="width:82px" %)((( 532 532 ADC3 579 + 533 533 (PA8) 534 534 ))) 535 535 ... ... @@ -544,21 +544,27 @@ 544 544 )))|=**2**|=**2**|=**2**|=**1**|=(% style="width: 193px;" %)**2**|=(% style="width: 78px;" %)4|=(% style="width: 78px;" %)4 545 545 |**Value**|BAT|((( 546 546 Temperature1(DS18B20) 594 + 547 547 (PC13) 548 548 )))|((( 549 549 Temperature2(DS18B20) 598 + 550 550 (PB9) 551 551 )))|((( 552 552 Digital Interrupt 602 + 553 553 (PB15) 554 554 )))|(% style="width:193px" %)((( 555 555 Temperature3(DS18B20) 606 + 556 556 (PB8) 557 557 )))|(% style="width:78px" %)((( 558 558 Count1 610 + 559 559 (PA8) 560 560 )))|(% style="width:78px" %)((( 561 561 Count2 614 + 562 562 (PA4) 563 563 ))) 564 564 ... ... @@ -630,7 +630,7 @@ 630 630 ((( 631 631 When the digital interrupt pin is set to AT+INTMODx=0, this pin is used as a digital input pin. 632 632 633 - (% style="color:red" %)**Note:**The maximum voltage input supports 3.6V.686 +**Note:**The maximum voltage input supports 3.6V. 634 634 ))) 635 635 636 636 ==== 2.3.3.4 Analogue Digital Converter (ADC) ==== ... ... @@ -641,18 +641,17 @@ 641 641 642 642 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220628150112-1.png?width=285&height=241&rev=1.1||alt="image-20220628150112-1.png" height="241" width="285"]] 643 643 644 - (% style="color:red" %)**Note:**If the ADC type sensor needs to be powered by SN50_v3, it is recommended to use +5V to control its switch.Only sensors with low power consumption can be powered with VDD.697 +**Note:**If the ADC type sensor needs to be powered by SN50_v3, it is recommended to use +5V to control its switch.Only sensors with low power consumption can be powered with VDD. 645 645 646 - 647 647 ==== 2.3.3.5 Digital Interrupt ==== 648 648 649 649 Digital Interrupt refers to pin PA8, and there are different trigger methods. When there is a trigger, the SN50v3 will send a packet to the server. 650 650 651 - (% style="color:blue" %)**~ Interrupt connection method:**703 +**~ Interrupt connection method:** 652 652 653 653 [[image:image-20230513105351-5.png||height="147" width="485"]] 654 654 655 - (% style="color:blue" %)**Example to use with door sensor :**707 +**Example to use with door sensor :** 656 656 657 657 The door sensor is shown at right. It is a two wire magnetic contact switch used for detecting the open/close status of doors or windows. 658 658 ... ... @@ -660,7 +660,7 @@ 660 660 661 661 When the two pieces are close to each other, the 2 wire output will be short or open (depending on the type), while if the two pieces are away from each other, the 2 wire output will be the opposite status. So we can use SN50_v3 interrupt interface to detect the status for the door or window. 662 662 663 - (% style="color:blue" %)**~ Below is the installation example:**715 +**~ Below is the installation example:** 664 664 665 665 Fix one piece of the magnetic sensor to the door and connect the two pins to SN50_v3 as follows: 666 666 ... ... @@ -685,7 +685,7 @@ 685 685 686 686 The command is: 687 687 688 - (% style="color:blue" %)**AT+INTMOD1=1 **(%%)~/~/(more info about INMOD please refer** **[[**AT Command Manual**>>url:http://www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/&file=DRAGINO_LSN50_AT_Commands_v1.5.1.pdf]]**. **)740 +**AT+INTMOD1=1 **~/~/(more info about INMOD please refer** **[[**AT Command Manual**>>url:http://www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/&file=DRAGINO_LSN50_AT_Commands_v1.5.1.pdf]]**. **) 689 689 690 690 Below shows some screen captures in TTN V3: 691 691 ... ... @@ -762,7 +762,7 @@ 762 762 763 763 The 5V output time can be controlled by AT Command. 764 764 765 - (% style="color:blue" %)**AT+5VT=1000**817 +**AT+5VT=1000** 766 766 767 767 Means set 5V valid time to have 1000ms. So the real 5V output will actually have 1000ms + sampling time for other sensors. 768 768 ... ... @@ -797,8 +797,6 @@ 797 797 * 7: MOD8 798 798 * 8: MOD9 799 799 800 - 801 - 802 802 == 2.4 Payload Decoder file == 803 803 804 804 ... ... @@ -876,7 +876,6 @@ 876 876 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 877 877 878 878 879 - 880 880 === 3.3.2 Get Device Status === 881 881 882 882 Send a LoRaWAN downlink to ask the device to send its status. ... ... @@ -925,7 +925,6 @@ 925 925 * Example 4: Downlink Payload: 06000201 **~-~-->** AT+INTMOD3=1 926 926 927 927 928 - 929 929 === 3.3.4 Set Power Output Duration === 930 930 931 931 Control the output duration 5V . Before each sampling, device will ... ... @@ -942,6 +942,7 @@ 942 942 |=(% style="width: 154px;background-color:#D9E2F3" %)**Command Example**|=(% style="width: 196px;background-color:#D9E2F3" %)**Function**|=(% style="width: 157px;background-color:#D9E2F3" %)**Response** 943 943 |(% style="width:154px" %)AT+5VT=?|(% style="width:196px" %)Show 5V open time.|(% style="width:157px" %)((( 944 944 500(default) 993 + 945 945 OK 946 946 ))) 947 947 |(% style="width:154px" %)AT+5VT=1000|(% style="width:196px" %)((( ... ... @@ -958,7 +958,6 @@ 958 958 * Example 2: Downlink Payload: 0701F4 **~-~-->** AT+5VT=500 959 959 960 960 961 - 962 962 === 3.3.5 Set Weighing parameters === 963 963 964 964 Feature: Working mode 5 is effective, weight initialization and weight factor setting of HX711. ... ... @@ -984,7 +984,6 @@ 984 984 * Example 3: Downlink Payload: 08020FA0 **~-~-->** AT+WEIGAP=400.0 985 985 986 986 987 - 988 988 === 3.3.6 Set Digital pulse count value === 989 989 990 990 Feature: Set the pulse count value. ... ... @@ -1008,7 +1008,6 @@ 1008 1008 * Example 2: Downlink Payload: 0902000003E8 **~-~-->** AT+SETCNT=2,1000 1009 1009 1010 1010 1011 - 1012 1012 === 3.3.7 Set Workmode === 1013 1013 1014 1014 Feature: Switch working mode. ... ... @@ -1022,6 +1022,7 @@ 1022 1022 ))) 1023 1023 |(% style="width:154px" %)AT+MOD=4|(% style="width:196px" %)Set the working mode to 3DS18B20s.|(% style="width:157px" %)((( 1024 1024 OK 1071 + 1025 1025 Attention:Take effect after ATZ 1026 1026 ))) 1027 1027 ... ... @@ -1033,7 +1033,6 @@ 1033 1033 * Example 2: Downlink Payload: 0A04 **~-~-->** AT+MOD=4 1034 1034 1035 1035 1036 - 1037 1037 = 4. Battery & Power Consumption = 1038 1038 1039 1039 ... ... @@ -1107,5 +1107,4 @@ 1107 1107 1108 1108 1109 1109 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1110 - 1111 1111 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.cc>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.cc]]