16 16  
17 17  == 1.1 What is SN50v3-LB LoRaWAN Generic Node ==
18 18  
19 -
20 20  (% style="color:blue" %)**SN50V3-LB **(%%)LoRaWAN Sensor Node is a Long Range LoRa Sensor Node. It is designed for outdoor use and powered by (% style="color:blue" %)** 8500mA Li/SOCl2 battery**(%%) for long term use.SN50V3-LB is designed to facilitate developers to quickly deploy industrial level LoRa and IoT solutions. It help users to turn the idea into a practical application and make the Internet of Things a reality. It is easy to program, create and connect your things everywhere.
21 21  
22 22  
... ... @@ -656,7 +656,7 @@
656 656  
657 657  ==== 2.3.3.2  Temperature (DS18B20) ====
658 658  
659 -If there is a DS18B20 connected to PC13 pin. The temperature will be uploaded in the payload.
658 +If there is a DS18B20 connected to PB3 pin. The temperature will be uploaded in the payload.
660 660  
661 661  More DS18B20 can check the [[3 DS18B20 mode>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/#2.3.4MOD3D4283xDS18B2029]]
662 662  
... ... @@ -685,8 +685,6 @@
685 685  When the digital interrupt pin is set to AT+INTMODx=0, this pin is used as a digital input pin.
686 686  
687 687  **Note:**The maximum voltage input supports 3.6V.
688 -
689 -
690 690  )))
691 691  
692 692  ==== 2.3.3.4  Analogue Digital Converter (ADC) ====
... ... @@ -699,7 +699,6 @@
699 699  
700 700  **Note:**If the ADC type sensor needs to be powered by SN50_v3, it is recommended to use +5V to control its switch.Only sensors with low power consumption can be powered with VDD.
701 701  
702 -
703 703  ==== 2.3.3.5 Digital Interrupt ====
704 704  
705 705  Digital Interrupt refers to pin PA8, and there are different trigger methods. When there is a trigger, the SN50v3 will send a packet to the server.
... ... @@ -853,8 +853,6 @@
853 853  * 7: MOD8
854 854  * 8: MOD9
855 855  
856 -== ==
857 -
858 858  == 2.4 Payload Decoder file ==
859 859  
860 860  
... ... @@ -931,8 +931,8 @@
931 931  * Example 1: Downlink Payload: 0100001E  ~/~/  Set Transmit Interval (TDC) = 30 seconds
932 932  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
933 933  
934 -=== ===
935 935  
929 +
936 936  === 3.3.2 Get Device Status ===
937 937  
938 938  Send a LoRaWAN downlink to ask the device to send its status.
... ... @@ -980,8 +980,8 @@
980 980  * Example 3: Downlink Payload: 06000102  **~-~-->**  AT+INTMOD2=2
981 981  * Example 4: Downlink Payload: 06000201  **~-~-->**  AT+INTMOD3=1
982 982  
983 -=== ===
984 984  
978 +
985 985  === 3.3.4 Set Power Output Duration ===
986 986  
987 987  Control the output duration 5V . Before each sampling, device will
... ... @@ -1014,8 +1014,8 @@
1014 1014  * Example 1: Downlink Payload: 070000  **~-~-->**  AT+5VT=0
1015 1015  * Example 2: Downlink Payload: 0701F4  **~-~-->**  AT+5VT=500
1016 1016  
1017 -=== ===
1018 1018  
1012 +
1019 1019  === 3.3.5 Set Weighing parameters ===
1020 1020  
1021 1021  Feature: Working mode 5 is effective, weight initialization and weight factor setting of HX711.
... ... @@ -1040,8 +1040,8 @@
1040 1040  * Example 2: Downlink Payload: 08020FA3  **~-~-->**  AT+WEIGAP=400.3
1041 1041  * Example 3: Downlink Payload: 08020FA0  **~-~-->**  AT+WEIGAP=400.0
1042 1042  
1043 -=== ===
1044 1044  
1038 +
1045 1045  === 3.3.6 Set Digital pulse count value ===
1046 1046  
1047 1047  Feature: Set the pulse count value.
... ... @@ -1064,8 +1064,8 @@
1064 1064  * Example 1: Downlink Payload: 090100000000  **~-~-->**  AT+SETCNT=1,0
1065 1065  * Example 2: Downlink Payload: 0902000003E8  **~-~-->**  AT+SETCNT=2,1000
1066 1066  
1067 -=== ===
1068 1068  
1062 +
1069 1069  === 3.3.7 Set Workmode ===
1070 1070  
1071 1071  Feature: Switch working mode.
... ... @@ -1090,8 +1090,8 @@
1090 1090  * Example 1: Downlink Payload: 0A01  **~-~-->**  AT+MOD=1
1091 1091  * Example 2: Downlink Payload: 0A04  **~-~-->**  AT+MOD=4
1092 1092  
1093 -= =
1094 1094  
1088 +
1095 1095  = 4. Battery & Power Consumption =
1096 1096  
1097 1097  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0